메뉴 건너뛰기




Volumn 23, Issue 3, 2008, Pages 1170-1178

Accurate prediction of damping in large interconnected power systems with the aid of regression analysis

Author keywords

Damping; Mode tracking; Phasor measurement unit; Regression analysis; Wide area measurement

Indexed keywords

BUSES; DAMPING; DECISION MAKING; ELECTRIC NETWORK ANALYSIS; ELECTRIC POWER SYSTEM INTERCONNECTION; ELECTRIC POWER SYSTEMS; ELECTRIC POWER TRANSMISSION NETWORKS; FOOD PROCESSING; FORECASTING; INTERCONNECTION NETWORKS; OPTIMIZATION; POWER TRANSMISSION; PROBLEM SOLVING; REGRESSION ANALYSIS; SENSITIVITY ANALYSIS; SYSTEM STABILITY;

EID: 49249129033     PISSN: 08858950     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRS.2008.926708     Document Type: Article
Times cited : (33)

References (20)
  • 1
    • 33846295388 scopus 로고    scopus 로고
    • States and Canada Causes and Recommendations, U.S.-Canada Power System Outage Task Force
    • 14 2003 Blackout in the United
    • Final Report on the August 14 2003 Blackout in the United States and Canada Causes and Recommendations, U.S.-Canada Power System Outage Task Force, 2004.
    • (2004) Final Report on the August
  • 2
    • 49249115283 scopus 로고    scopus 로고
    • Steps to Establish a Transmission Monitoring System for Transmission Owners and Operators Within the Eastern and Western Interconnections, U.S. DOE and FERC, Report to Congress, 2006
    • Steps to Establish a Transmission Monitoring System for Transmission Owners and Operators Within the Eastern and Western Interconnections, U.S. DOE and FERC, Report to Congress, 2006.
  • 3
    • 27144554606 scopus 로고    scopus 로고
    • Monitoring and predicting power system behaviour by tracking dominant modes of oscillation
    • San Francisco, CA, Jul
    • B. A. Archer and U. D. Annakkage, "Monitoring and predicting power system behaviour by tracking dominant modes of oscillation," in Proc. IEEE Power Eng. Soc. General Meeting, San Francisco, CA, Jul. 2005.
    • (2005) Proc. IEEE Power Eng. Soc. General Meeting
    • Archer, B.A.1    Annakkage, U.D.2
  • 4
    • 0032592968 scopus 로고    scopus 로고
    • Performance comparison of three identification methods for the analysis of electromechanical oscillations
    • Aug
    • J. J. Sanchez-Gasca and J. H. Chow, "Performance comparison of three identification methods for the analysis of electromechanical oscillations," IEEE Trans. Power Syst., vol. 14, no. 3, pp. 995-1002, Aug. 1999.
    • (1999) IEEE Trans. Power Syst , vol.14 , Issue.3 , pp. 995-1002
    • Sanchez-Gasca, J.J.1    Chow, J.H.2
  • 5
    • 49249115684 scopus 로고    scopus 로고
    • J. F. Hauer, W. A. Mittelstadt, K. E. Martin, J. W. Burns, and H. Lee, Integrated dynamic information for the western power system: WAMS analysis in 2005, in Power System Stability and Control Electric Power Engineering Handbook, Disturbance Monitoring Work Group of the Western Electricity Coordinating Council, L. Grigsby, Ed., 2 ed. Boca Raton, FL: CRC Press, 2007, ch. 14.
    • J. F. Hauer, W. A. Mittelstadt, K. E. Martin, J. W. Burns, and H. Lee, "Integrated dynamic information for the western power system: WAMS analysis in 2005," in Power System Stability and Control Volume, Electric Power Engineering Handbook, Disturbance Monitoring Work Group of the Western Electricity Coordinating Council, L. Grigsby, Ed., 2 ed. Boca Raton, FL: CRC Press, 2007, ch. 14.
  • 7
    • 49249122504 scopus 로고    scopus 로고
    • Use of the WECC WAMS in Staged System Tests for Validation of System Performance and Modeling
    • August, Interim report of the WECC Disturbance Monitoring Work Group
    • J. F. Hauer, W. A. Mittelstadt, J. W. Burns, K. E. Martin, H. Lee, and D. J. Trudnowski, Use of the WECC WAMS in Staged System Tests for Validation of System Performance and Modeling: Summary Report for September 2005 - August 2006, Interim report of the WECC Disturbance Monitoring Work Group, 2007.
    • (2006) Summary Report for September 2005 , pp. 2007
    • Hauer, J.F.1    Mittelstadt, W.A.2    Burns, J.W.3    Martin, K.E.4    Lee, H.5    Trudnowski, D.J.6
  • 8
    • 49249084567 scopus 로고    scopus 로고
    • Wide Area Measurements for Real-Time Control and Operation of Large Electric Power Systems, Evaluation and Demonstration of Technology for the New Power System, report prepared for the U.S. Department of Energy under BPA Contracts X5432-1, X9876-2, U.S. DOE, 1999
    • Wide Area Measurements for Real-Time Control and Operation of Large Electric Power Systems - Evaluation and Demonstration of Technology for the New Power System, report prepared for the U.S. Department of Energy under BPA Contracts X5432-1, X9876-2, U.S. DOE, 1999.
  • 9
    • 15944372211 scopus 로고    scopus 로고
    • Managing oscillatory stability using on-line dynamics measurements
    • New York, Oct
    • D. H. Wilson, "Managing oscillatory stability using on-line dynamics measurements," in Proc. IEEE Power Systems Conf. Expo., New York, Oct. 2004.
    • (2004) Proc. IEEE Power Systems Conf. Expo
    • Wilson, D.H.1
  • 11
    • 33847626421 scopus 로고    scopus 로고
    • Derivation of an accurate polynomial representation of the transient stability boundary
    • Nov
    • B. Jayasekara and U. D. Annakkage, "Derivation of an accurate polynomial representation of the transient stability boundary," IEEE Trans. Power Syst., vol. 21, no. 4, pp. 1856-1863, Nov. 2006.
    • (2006) IEEE Trans. Power Syst , vol.21 , Issue.4 , pp. 1856-1863
    • Jayasekara, B.1    Annakkage, U.D.2
  • 12
    • 0030087026 scopus 로고    scopus 로고
    • Contingency severity assessment for voltage security using non-parametric regression techniques
    • Feb
    • L. Wehenkel, "Contingency severity assessment for voltage security using non-parametric regression techniques," IEEE Trans. Power Syst. vol. 11, no. 1, pp. 101-111, Feb. 1996.
    • (1996) IEEE Trans. Power Syst , vol.11 , Issue.1 , pp. 101-111
    • Wehenkel, L.1
  • 13
    • 33947101620 scopus 로고    scopus 로고
    • SOFM based support vector regression model for prediction and its application in power system transient stability forcasting
    • D. H. Li and Y. J. Cao, "SOFM based support vector regression model for prediction and its application in power system transient stability forcasting," in Proc. Power Engineering Conf., 7th Int. IPEC Conf. 2005.
    • (2005) Proc. Power Engineering Conf., 7th Int. IPEC Conf
    • Li, D.H.1    Cao, Y.J.2
  • 14
    • 0036089250 scopus 로고    scopus 로고
    • Dual configuration, dual setting, digital power system stabilizer - Simulation and tuning experience at Manitoba Hydro
    • New York, Feb
    • B. A. Archer, L. E. Midford, and J. B. Davies, "Dual configuration, dual setting, digital power system stabilizer - Simulation and tuning experience at Manitoba Hydro," in Proc. IEEE Power Eng. Soc. Winter Meeting 2002, New York, Feb. 2002.
    • (2002) Proc. IEEE Power Eng. Soc. Winter Meeting 2002
    • Archer, B.A.1    Midford, L.E.2    Davies, J.B.3
  • 16
    • 85011879783 scopus 로고    scopus 로고
    • Validation of on-line power system dynamics measurements
    • Edmonton, AB, Canada, Jul
    • T. Anderson and A. Golder, "Validation of on-line power system dynamics measurements," in Proc. IEEE Power Eng. Soc. Summer Meeting, Edmonton, AB, Canada, Jul. 1999.
    • (1999) Proc. IEEE Power Eng. Soc. Summer Meeting
    • Anderson, T.1    Golder, A.2
  • 20


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.