메뉴 건너뛰기




Volumn 2, Issue 3, 2006, Pages

CT-guided percutaneous biopsy of spinal lesions

Author keywords

Biopsy; Computed tomography; Intervention; Percutaneous biopsy; Spine; Vertebral lesions

Indexed keywords

BIOPSY TECHNIQUE; BLEEDING; BONE INFECTION; COMPUTER ASSISTED TOMOGRAPHY; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; ECHOGRAPHY; FLUOROSCOPY; HISTOPATHOLOGY; HUMAN; LOCAL ANESTHESIA; NEUROLOGIC DISEASE; NUCLEAR MAGNETIC RESONANCE IMAGING; PATHOLOGICAL ANATOMY; PATIENT SAFETY; PERCUTANEOUS BIOPSY; PNEUMOTHORAX; REVIEW; SPINAL CORD COMPRESSION; SPINE DISEASE; SPINE METASTASIS; TREATMENT PLANNING;

EID: 49149110032     PISSN: None     EISSN: 18235530     Source Type: Journal    
DOI: 10.2349/biij.2.3.e25     Document Type: Review
Times cited : (61)

References (49)
  • 1
    • 0019415639 scopus 로고
    • Percutaneous skeletal biopsy 1981: A procedure for radiologists - results, review, and recommendations
    • Murphy WA, Destouet JM, Gilula LA. Percutaneous skeletal biopsy 1981: a procedure for radiologists - results, review, and recommendations. Radiology 1981;139(3):545-9.
    • (1981) Radiology , vol.139 , Issue.3 , pp. 545-549
    • Murphy, W.A.1    Destouet, J.M.2    Gilula, L.A.3
  • 2
  • 3
    • 0033499794 scopus 로고    scopus 로고
    • Percutaneous biopsy of the thoracic and lumbar spine: Transpedicular approach under fluoroscopic guidance
    • Pierot L, Boulin A. Percutaneous biopsy of the thoracic and lumbar spine: transpedicular approach under fluoroscopic guidance. AJNR Am J Neuroradiol 1999;20(1):23-5.
    • (1999) AJNR Am J Neuroradiol , vol.20 , Issue.1 , pp. 23-25
    • Pierot, L.1    Boulin, A.2
  • 4
    • 0033391965 scopus 로고    scopus 로고
    • Percutaneous transpedicular biopsy of thoracic and lumbar vertebrae - method and diagnostic validity
    • Ashizawa R, Ohtsuka K, Kamimura M, et al. Percutaneous transpedicular biopsy of thoracic and lumbar vertebrae - method and diagnostic validity. Surg Neurol 1999;52(6):545-51.
    • (1999) Surg Neurol , vol.52 , Issue.6 , pp. 545-551
    • Ashizawa, R.1    Ohtsuka, K.2    Kamimura, M.3
  • 5
    • 0025812759 scopus 로고
    • CT-guided percutaneous transpedicular biopsy of the spine
    • Renfrew DL, Whitten CG, Wiese JA, et al. CT-guided percutaneous transpedicular biopsy of the spine. Radiology 1991;180(2):574-6.
    • (1991) Radiology , vol.180 , Issue.2 , pp. 574-576
    • Renfrew, D.L.1    Whitten, C.G.2    Wiese, J.A.3
  • 6
    • 0028135227 scopus 로고
    • Computed tomographically guided biopsy of the spine
    • Babu NV, Titus VT, Chittaranjan S, et al. Computed tomographically guided biopsy of the spine. Spine 1994;19(21):2436-42.
    • (1994) Spine , vol.19 , Issue.21 , pp. 2436-2442
    • Babu, N.V.1    Titus, V.T.2    Chittaranjan, S.3
  • 7
    • 0031753903 scopus 로고    scopus 로고
    • Accuracy of CT-guided needle biopsy of musculoskeletal neoplasms
    • Dupuy DE, Rosenberg AE, Punyaratabandhu T, et al. Accuracy of CT-guided needle biopsy of musculoskeletal neoplasms. AJR Am J Roentgenol 1998;171(3):759-62.
    • (1998) AJR Am J Roentgenol , vol.171 , Issue.3 , pp. 759-762
    • Dupuy, D.E.1    Rosenberg, A.E.2    Punyaratabandhu, T.3
  • 8
    • 0031907755 scopus 로고    scopus 로고
    • Computed tomography-guided biopsy of the spine. A review of 103 patients
    • Kornblum MB, Wesolowski DP, Fischgrund JS, et al. Computed tomography-guided biopsy of the spine. A review of 103 patients. Spine 1998;23(1):81-5.
    • (1998) Spine , vol.23 , Issue.1 , pp. 81-85
    • Kornblum, M.B.1    Wesolowski, D.P.2    Fischgrund, J.S.3
  • 9
    • 0032706683 scopus 로고    scopus 로고
    • CT-guided percutaneous biopsy of sclerotic bone lesions: Diagnostic yield and accuracy
    • Leffler SG, Chew FS. CT-guided percutaneous biopsy of sclerotic bone lesions: diagnostic yield and accuracy. AJR Am J Roentgenol 1999;172(5):1389-92.
    • (1999) AJR Am J Roentgenol , vol.172 , Issue.5 , pp. 1389-1392
    • Leffler, S.G.1    Chew, F.S.2
  • 10
    • 0033192462 scopus 로고    scopus 로고
    • CT-guided fine-needle aspiration biopsy of spinal lesions
    • Kang M, Gupta S, Khandelwal N, et al. CT-guided fine-needle aspiration biopsy of spinal lesions. Acta Radiol 1999;40(5):474-8.
    • (1999) Acta Radiol , vol.40 , Issue.5 , pp. 474-478
    • Kang, M.1    Gupta, S.2    Khandelwal, N.3
  • 11
    • 0033956632 scopus 로고    scopus 로고
    • Lateral access for CT-guided percutaneous biopsy of the lumbar spine
    • Garces J, Hidalgo G. Lateral access for CT-guided percutaneous biopsy of the lumbar spine. AJR Am J Roentgenol 2000;174(2):425-6.
    • (2000) AJR Am J Roentgenol , vol.174 , Issue.2 , pp. 425-426
    • Garces, J.1    Hidalgo, G.2
  • 12
    • 0035131022 scopus 로고    scopus 로고
    • Diagnostic yield of CT-guided percutaneous aspiration procedures in suspected spontaneous infectious diskitis
    • Chew FS, Kline MJ. Diagnostic yield of CT-guided percutaneous aspiration procedures in suspected spontaneous infectious diskitis. Radiology 2001;218(1):211-4.
    • (2001) Radiology , vol.218 , Issue.1 , pp. 211-214
    • Chew, F.S.1    Kline, M.J.2
  • 13
    • 0036935120 scopus 로고    scopus 로고
    • Accuracy of CT-guided biopsies in 359 patients with musculoskeletal lesions
    • Hau A, Kim I, Kattapuram S, et al. Accuracy of CT-guided biopsies in 359 patients with musculoskeletal lesions. Skeletal Radiol 2002;31(6):349-53.
    • (2002) Skeletal Radiol , vol.31 , Issue.6 , pp. 349-353
    • Hau, A.1    Kim, I.2    Kattapuram, S.3
  • 14
    • 0242583730 scopus 로고    scopus 로고
    • CT-guided percutaneous needle biopsy in spine lesions
    • Ozsarlak O, De Schepper AM, Wang X, et al. CT-guided percutaneous needle biopsy in spine lesions. JBR-BTR 2003;86(5):294-6.
    • (2003) JBR-BTR , vol.86 , Issue.5 , pp. 294-296
    • Ozsarlak, O.1    De Schepper, A.M.2    Wang, X.3
  • 15
    • 0038544704 scopus 로고    scopus 로고
    • Computerized tomography-guided percutaneous transforaminodiscal biopsy sampling of vertebral body lesions
    • Sucu HK, Bezircioglu H, Cicek C, et al. Computerized tomography-guided percutaneous transforaminodiscal biopsy sampling of vertebral body lesions. J Neurosurg 2003;99(1 Suppl):51-5.
    • (2003) J Neurosurg , vol.99 , Issue.1 SUPPL. , pp. 51-55
    • Sucu, H.K.1    Bezircioglu, H.2    Cicek, C.3
  • 16
    • 0345254968 scopus 로고    scopus 로고
    • CT-guided percutaneous biopsy of thoracic and lumbar spine: A new coaxial technique
    • Yaffe D, Greenberg G, Leitner J, et al. CT-guided percutaneous biopsy of thoracic and lumbar spine: A new coaxial technique. AJNR Am J Neuroradiol 2003;24(10):2111-3.
    • (2003) AJNR Am J Neuroradiol , vol.24 , Issue.10 , pp. 2111-2113
    • Yaffe, D.1    Greenberg, G.2    Leitner, J.3
  • 17
    • 16644368109 scopus 로고    scopus 로고
    • Percutaneous CT-guided biopsy of osseous lesion of the spine in patients with known or suspected malignancy
    • Lis E, Bilsky MH, Pisinski L, et al. Percutaneous CT-guided biopsy of osseous lesion of the spine in patients with known or suspected malignancy. AJNR Am J Neuroradiol 2004;25(9):1583-8.
    • (2004) AJNR Am J Neuroradiol , vol.25 , Issue.9 , pp. 1583-1588
    • Lis, E.1    Bilsky, M.H.2    Pisinski, L.3
  • 18
    • 18244381541 scopus 로고    scopus 로고
    • Accuracy of computed tomography guided core needle biopsy of musculoskeletal tumours
    • Altuntas AO, Slavin J, Smith PJ, et al. Accuracy of computed tomography guided core needle biopsy of musculoskeletal tumours. ANZ J Surg 2005;75(4):187-91.
    • (2005) ANZ J Surg , vol.75 , Issue.4 , pp. 187-191
    • Altuntas, A.O.1    Slavin, J.2    Smith, P.J.3
  • 19
    • 33646933606 scopus 로고    scopus 로고
    • CT-guided core biopsy of subchondral bone and intervertebral space in suspected spondylodiskitis
    • Michel SC, Pfirrmann CW, Boos N, et al. CT-guided core biopsy of subchondral bone and intervertebral space in suspected spondylodiskitis. AJR Am J Roentgenol 2006;186(4):977-80.
    • (2006) AJR Am J Roentgenol , vol.186 , Issue.4 , pp. 977-980
    • Michel, S.C.1    Pfirrmann, C.W.2    Boos, N.3
  • 20
    • 0028302562 scopus 로고
    • Lytic bone lesions suspected for metastasis: Ultrasonically guided fine-needle aspiration biopsy
    • Civardi G, Livraghi T, Colombo P, et al. Lytic bone lesions suspected for metastasis: ultrasonically guided fine-needle aspiration biopsy. J Clin Ultrasound 1994;22(5):307-11.
    • (1994) J Clin Ultrasound , vol.22 , Issue.5 , pp. 307-311
    • Civardi, G.1    Livraghi, T.2    Colombo, P.3
  • 21
    • 0032972545 scopus 로고    scopus 로고
    • Sonographically guided fine-needle aspiration biopsy of lytic lesions of the spine: Technique and indications
    • Gupta S, Takhtani D, Gulati M, et al. Sonographically guided fine-needle aspiration biopsy of lytic lesions of the spine: technique and indications. J Clin Ultrasound 1999;27(3):123-9.
    • (1999) J Clin Ultrasound , vol.27 , Issue.3 , pp. 123-129
    • Gupta, S.1    Takhtani, D.2    Gulati, M.3
  • 22
    • 0033978598 scopus 로고    scopus 로고
    • Ultrasound-guided needle biopsy of primary bone tumours
    • Saifuddin A, Mitchell R, Burnett SJ, et al. Ultrasound-guided needle biopsy of primary bone tumours. J Bone Joint Surg Br 2000;82(1):50-4.
    • (2000) J Bone Joint Surg Br , vol.82 , Issue.1 , pp. 50-54
    • Saifuddin, A.1    Mitchell, R.2    Burnett, S.J.3
  • 23
    • 0033775246 scopus 로고    scopus 로고
    • Ultrasonographically guided needle biopsy of benign and malignant soft tissue and bone tumors
    • Konermann W, Wuisman P, Ellermann A, et al. Ultrasonographically guided needle biopsy of benign and malignant soft tissue and bone tumors. J Ultrasound Med 2000;19(7):465-71.
    • (2000) J Ultrasound Med , vol.19 , Issue.7 , pp. 465-471
    • Konermann, W.1    Wuisman, P.2    Ellermann, A.3
  • 25
    • 0031808949 scopus 로고    scopus 로고
    • Interactive MR imaging-guided biopsy and aspiration with a modified clinical C-arm system
    • Lewin JS, Petersilge CA, Hatem SF, et al. Interactive MR imaging-guided biopsy and aspiration with a modified clinical C-arm system. AJR Am J Roentgenol 1998;170(6):1593-601.
    • (1998) AJR Am J Roentgenol , vol.170 , Issue.6 , pp. 1593-1601
    • Lewin, J.S.1    Petersilge, C.A.2    Hatem, S.F.3
  • 26
    • 0035037895 scopus 로고    scopus 로고
    • MR-guided biopsy of musculoskeletal lesions in a low-field system
    • Koenig CW, Duda SH, Truebenbach J, et al. MR-guided biopsy of musculoskeletal lesions in a low-field system. J Magn Reson Imaging 2001;13(5):761-8.
    • (2001) J Magn Reson Imaging , vol.13 , Issue.5 , pp. 761-768
    • Koenig, C.W.1    Duda, S.H.2    Truebenbach, J.3
  • 27
    • 0036208348 scopus 로고    scopus 로고
    • Interventional musculoskeletal procedures performed by using MR imaging guidance with a vertically open MR unit: Assessment of techniques and applicability
    • Genant JW, Vandevenne JE, Bergman AG, et al. Interventional musculoskeletal procedures performed by using MR imaging guidance with a vertically open MR unit: assessment of techniques and applicability. Radiology 2002;223(1):127-36.
    • (2002) Radiology , vol.223 , Issue.1 , pp. 127-136
    • Genant, J.W.1    Vandevenne, J.E.2    Bergman, A.G.3
  • 28
    • 0037898142 scopus 로고    scopus 로고
    • Magnetic resonance imaging guided bone biopsies in the iPath-200 system
    • Wu L, Li C, Chen L, et al. Magnetic resonance imaging guided bone biopsies in the iPath-200 system. Chin Med J (Engl) 2003;116(6):937-40.
    • (2003) Chin Med J (Engl) , vol.116 , Issue.6 , pp. 937-940
    • Wu, L.1    Li, C.2    Chen, L.3
  • 29
    • 0014263890 scopus 로고
    • Puncture biopsy in lesions of the locomotor system. Review of results in 4050 cases, including 941 vertebral punctures
    • Schajowicz F, Derqui JC. Puncture biopsy in lesions of the locomotor system. Review of results in 4050 cases, including 941 vertebral punctures. Cancer 1968;21(3):531-48.
    • (1968) Cancer , vol.21 , Issue.3 , pp. 531-548
    • Schajowicz, F.1    Derqui, J.C.2
  • 30
    • 0020687272 scopus 로고
    • Radiologically guided percutaneous musculoskeletal biopsy
    • Murphy WA. Radiologically guided percutaneous musculoskeletal biopsy. Orthop Clin North Am 1983;14(1):233-41.
    • (1983) Orthop Clin North Am , vol.14 , Issue.1 , pp. 233-241
    • Murphy, W.A.1
  • 31
    • 0029967186 scopus 로고    scopus 로고
    • Diagnostic accuracy and charge-savings of outpatient core needle biopsy compared with open biopsy of musculoskeletal tumors
    • Skrzynski MC, Biermann JS, Montag A, et al. Diagnostic accuracy and charge-savings of outpatient core needle biopsy compared with open biopsy of musculoskeletal tumors. J Bone Joint Surg Am 1996;78(5):644-9.
    • (1996) J Bone Joint Surg Am , vol.78 , Issue.5 , pp. 644-649
    • Skrzynski, M.C.1    Biermann, J.S.2    Montag, A.3
  • 32
    • 0020527394 scopus 로고
    • Percutaneous bone biopsy: The importance of aspirated osseous blood
    • Hewes RC, Vigorita VJ, Freiberger RH. Percutaneous bone biopsy: the importance of aspirated osseous blood. Radiology 1983;148(1):69-72.
    • (1983) Radiology , vol.148 , Issue.1 , pp. 69-72
    • Hewes, R.C.1    Vigorita, V.J.2    Freiberger, R.H.3
  • 34
    • 0026158528 scopus 로고
    • Needle biopsy of musculoskeletal lesions. A review of 208 procedures
    • Stoker DJ, Cobb JP, Pringle JA. Needle biopsy of musculoskeletal lesions. A review of 208 procedures. J Bone Joint Surg Br 1991;73(3):498-500.
    • (1991) J Bone Joint Surg Br , vol.73 , Issue.3 , pp. 498-500
    • Stoker, D.J.1    Cobb, J.P.2    Pringle, J.A.3
  • 35
  • 36
    • 0031894982 scopus 로고    scopus 로고
    • Radiologically guided bone biopsy: Results of 502 biopsies
    • Ng CS, Salisbury JR, Darby AJ, et al. Radiologically guided bone biopsy: results of 502 biopsies. Cardiovasc Intervent Radiol 1998;21(2):122-8.
    • (1998) Cardiovasc Intervent Radiol , vol.21 , Issue.2 , pp. 122-128
    • Ng, C.S.1    Salisbury, J.R.2    Darby, A.J.3
  • 37
    • 0033050103 scopus 로고    scopus 로고
    • Percutaneous biopsy of the musculoskeletal system: A review of 77 cases
    • Hodge JC. Percutaneous biopsy of the musculoskeletal system: a review of 77 cases. Can Assoc Radiol J 1999;50(2):121-5.
    • (1999) Can Assoc Radiol J , vol.50 , Issue.2 , pp. 121-125
    • Hodge, J.C.1
  • 38
    • 0030048855 scopus 로고    scopus 로고
    • Image-guided percutaneous biopsy of musculoskeletal tumors: An algorithm for selection of specific biopsy techniques
    • Logan PM, Connell DG, O'connell JX, et al. Image-guided percutaneous biopsy of musculoskeletal tumors: an algorithm for selection of specific biopsy techniques. AJR Am J Roentgenol 1996;166(1):137-41.
    • (1996) AJR Am J Roentgenol , vol.166 , Issue.1 , pp. 137-141
    • Logan, P.M.1    Connell, D.G.2    O'connell, J.X.3
  • 39
    • 0141518416 scopus 로고    scopus 로고
    • CT arthrography of the glenohumeral joint: CT fluoroscopy versus conventional CT and fluoroscopy - comparison of image-guidance techniques
    • Binkert CA, Verdun FR, Zanetti M, et al. CT arthrography of the glenohumeral joint: CT fluoroscopy versus conventional CT and fluoroscopy - comparison of image-guidance techniques. Radiology 2003;229(1):153-8.
    • (2003) Radiology , vol.229 , Issue.1 , pp. 153-158
    • Binkert, C.A.1    Verdun, F.R.2    Zanetti, M.3
  • 40
    • 0141782332 scopus 로고    scopus 로고
    • Imaging-guided bone biopsy
    • Peh WC. Imaging-guided bone biopsy. Ann Acad Med Singapore 2003;32(4):557-61.
    • (2003) Ann Acad Med Singapore , vol.32 , Issue.4 , pp. 557-561
    • Peh, W.C.1
  • 41
    • 57149119236 scopus 로고    scopus 로고
    • Hodge JC. Bone biopsies. Hodge JC, ed. Musculoskeletal Imaging: Diagnostic and Therapeutic Procedures. Basel: Karger Landes, 1997:203-22.
    • Hodge JC. Bone biopsies. Hodge JC, ed. Musculoskeletal Imaging: Diagnostic and Therapeutic Procedures. Basel: Karger Landes, 1997:203-22.
  • 42
    • 0031749851 scopus 로고    scopus 로고
    • Biopsies of the musculoskeletal system
    • Ghelman B. Biopsies of the musculoskeletal system. Radiol Clin North Am 1998;36(3):567-80.
    • (1998) Radiol Clin North Am , vol.36 , Issue.3 , pp. 567-580
    • Ghelman, B.1
  • 43
    • 57149092280 scopus 로고    scopus 로고
    • Musculoskeletal tumors, percutaneous needle biopsy
    • Hallet RL. Musculoskeletal tumors, percutaneous needle biopsy. EMedicine J 2002.
    • (2002) EMedicine J
    • Hallet, R.L.1
  • 44
    • 19444386719 scopus 로고    scopus 로고
    • Assessment of bone biopsy needles for sample size, specimen quality and ease of use
    • Roberts CC, Morrison WB, Leslie KO, et al. Assessment of bone biopsy needles for sample size, specimen quality and ease of use. Skeletal Radiol 2005;34(6):329-35.
    • (2005) Skeletal Radiol , vol.34 , Issue.6 , pp. 329-335
    • Roberts, C.C.1    Morrison, W.B.2    Leslie, K.O.3
  • 45
    • 0028807923 scopus 로고
    • Study of osteomyelitis: Utility of combined histologic and microbiologic evaluation of percutaneous biopsy samples
    • White LM, Schweitzer ME, Deely DM, et al. Study of osteomyelitis: utility of combined histologic and microbiologic evaluation of percutaneous biopsy samples. Radiology 1995;197(3):840-2.
    • (1995) Radiology , vol.197 , Issue.3 , pp. 840-842
    • White, L.M.1    Schweitzer, M.E.2    Deely, D.M.3
  • 46
    • 0030066489 scopus 로고    scopus 로고
    • Percutaneous skeletal aspiration and core biopsy: Complementary techniques
    • Schweitzer ME, Gannon FH, Deely DM, et al. Percutaneous skeletal aspiration and core biopsy: complementary techniques. AJR Am J Roentgenol 1996;166(2):415-8.
    • (1996) AJR Am J Roentgenol , vol.166 , Issue.2 , pp. 415-418
    • Schweitzer, M.E.1    Gannon, F.H.2    Deely, D.M.3
  • 47
    • 0029196367 scopus 로고
    • Biopsy techniques for skin, soft-tissue, and bone neoplasms
    • Arca MJ, Biermann JS, Johnson TM, et al. Biopsy techniques for skin, soft-tissue, and bone neoplasms. Surg Oncol Clin N Am 1995;4(1):157-74.
    • (1995) Surg Oncol Clin N Am , vol.4 , Issue.1 , pp. 157-174
    • Arca, M.J.1    Biermann, J.S.2    Johnson, T.M.3
  • 48
    • 0029882587 scopus 로고    scopus 로고
    • The hazards of the biopsy, revisited. Members of the Musculoskeletal Tumor Society
    • Mankin HJ, Mankin CJ, Simon MA. The hazards of the biopsy, revisited. Members of the Musculoskeletal Tumor Society. J Bone Joint Surg Am 1996;78(5):656-63.
    • (1996) J Bone Joint Surg Am , vol.78 , Issue.5 , pp. 656-663
    • Mankin, H.J.1    Mankin, C.J.2    Simon, M.A.3
  • 49
    • 0030829661 scopus 로고    scopus 로고
    • Complications of CT-guided biopsy of the spine and sacrum
    • Olscamp A, Rollins J, Tao SS, et al. Complications of CT-guided biopsy of the spine and sacrum. Orthopedics 1997;20(12):1149-52.
    • (1997) Orthopedics , vol.20 , Issue.12 , pp. 1149-1152
    • Olscamp, A.1    Rollins, J.2    Tao, S.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.