메뉴 건너뛰기




Volumn 43, Issue 12, 2008, Pages 1991-2004

Towards the application of indoor ventilation efficiency indices to evaluate the air quality of urban areas

Author keywords

Air quality; CFD; Urban domains; Ventilation efficiency

Indexed keywords

AIR POLLUTION; AIR QUALITY; BUILDINGS; COMMUNICATION CHANNELS (INFORMATION THEORY); COMPUTATIONAL FLUID DYNAMICS; COMPUTER SIMULATION; DYNAMICS; FLUID DYNAMICS; FLUID MECHANICS; INDOOR AIR POLLUTION; POLLUTION; REGIONAL PLANNING; ROADS AND STREETS; VENTILATION;

EID: 49149110000     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.buildenv.2007.11.013     Document Type: Article
Times cited : (126)

References (25)
  • 2
    • 0024475637 scopus 로고
    • A general finite line source model for vehicular pollution prediction
    • Luhar A.K., and Patil R.S. A general finite line source model for vehicular pollution prediction. Atmospheric Environment 23 3 (1989) 555-562
    • (1989) Atmospheric Environment , vol.23 , Issue.3 , pp. 555-562
    • Luhar, A.K.1    Patil, R.S.2
  • 3
    • 23044460801 scopus 로고    scopus 로고
    • Impact of building configuration on air quality in street canyon
    • Xiaomine X., Huang Z., and Wang J. Impact of building configuration on air quality in street canyon. Atmospheric Environment 39 25 (2005) 4519-4530
    • (2005) Atmospheric Environment , vol.39 , Issue.25 , pp. 4519-4530
    • Xiaomine, X.1    Huang, Z.2    Wang, J.3
  • 4
    • 4744338271 scopus 로고    scopus 로고
    • Measurements and three-dimensional modeling of air pollutant dispersion in an urban street canyon
    • Tsai M.Y., and Chen K.S. Measurements and three-dimensional modeling of air pollutant dispersion in an urban street canyon. Atmospheric Environment 38 35 (2004) 5911-5924
    • (2004) Atmospheric Environment , vol.38 , Issue.35 , pp. 5911-5924
    • Tsai, M.Y.1    Chen, K.S.2
  • 6
    • 20344365591 scopus 로고    scopus 로고
    • Wind tunnel modeling of urban building exposure to outdoor pollution
    • Mfula A., Kukadia V., Griffiths R., and Hall D. Wind tunnel modeling of urban building exposure to outdoor pollution. Atmospheric Environment 39 15 (2005) 2737-2745
    • (2005) Atmospheric Environment , vol.39 , Issue.15 , pp. 2737-2745
    • Mfula, A.1    Kukadia, V.2    Griffiths, R.3    Hall, D.4
  • 7
    • 0032539057 scopus 로고    scopus 로고
    • A comparison of results from scaled field and wind tunnel modeling of dispersion in arrays of obstacles
    • Macdonald R., Griffiths R., and Hall D. A comparison of results from scaled field and wind tunnel modeling of dispersion in arrays of obstacles. Atmospheric Environment 32 22 (1998) 3845-3862
    • (1998) Atmospheric Environment , vol.32 , Issue.22 , pp. 3845-3862
    • Macdonald, R.1    Griffiths, R.2    Hall, D.3
  • 8
    • 49149102319 scopus 로고    scopus 로고
    • Ishida Y, Kato S, Zheng B, Huang H, Takao S, Wataru K, et al. Study on wind environment in urban blocks by CFD, Part 5: Definition and calculation method of exceedance probabilities for ventilation performance in a void space. In: Proceedings of the annual meeting of the Architectural Institute of Japan (AIJ), (D-2); 2007. p. 675-6 (in Japanese).
    • Ishida Y, Kato S, Zheng B, Huang H, Takao S, Wataru K, et al. Study on wind environment in urban blocks by CFD, Part 5: Definition and calculation method of exceedance probabilities for ventilation performance in a void space. In: Proceedings of the annual meeting of the Architectural Institute of Japan (AIJ), (D-2); 2007. p. 675-6 (in Japanese).
  • 9
    • 49149092991 scopus 로고    scopus 로고
    • Sandberg M. Ventilation effectiveness and purging flow rate-a review. In: International symposium on room air convection and ventilation effectiveness; 1992. p. 1-21.
    • Sandberg M. Ventilation effectiveness and purging flow rate-a review. In: International symposium on room air convection and ventilation effectiveness; 1992. p. 1-21.
  • 10
    • 49149110106 scopus 로고    scopus 로고
    • Ito K, Kato S, Murakami S. Study of visitation frequency and purging flow rate based on averaged contaminant distribution-study on evaluating of ventilation effectiveness of occupied space in room. Japanese Journal of Architecture Planning and Environmental Engineering (Transaction of AIJ) 2000;529:31-7 (in Japanese).
    • Ito K, Kato S, Murakami S. Study of visitation frequency and purging flow rate based on averaged contaminant distribution-study on evaluating of ventilation effectiveness of occupied space in room. Japanese Journal of Architecture Planning and Environmental Engineering (Transaction of AIJ) 2000;529:31-7 (in Japanese).
  • 11
    • 0041384535 scopus 로고    scopus 로고
    • Analysis of visitation frequency through particle tracking method based on LES and model experiment
    • Kato S., Ito K., and Murakami S. Analysis of visitation frequency through particle tracking method based on LES and model experiment. Indoor Air 13 2 (2003) 182-193
    • (2003) Indoor Air , vol.13 , Issue.2 , pp. 182-193
    • Kato, S.1    Ito, K.2    Murakami, S.3
  • 12
    • 49149116635 scopus 로고    scopus 로고
    • Uehara K, Murakami S, Oikawa S, Wakamatsu S. Wind tunnel test of concentration fields around street canyons within the stratified urban canopy layer, Part 3: Experimental studies on gaseous diffusion in urban areas. Journal of Architecture Planning and Environmental Engineering (Transaction of AIJ) 1997;499:9-16 (in Japanese).
    • Uehara K, Murakami S, Oikawa S, Wakamatsu S. Wind tunnel test of concentration fields around street canyons within the stratified urban canopy layer, Part 3: Experimental studies on gaseous diffusion in urban areas. Journal of Architecture Planning and Environmental Engineering (Transaction of AIJ) 1997;499:9-16 (in Japanese).
  • 13
    • 33748991993 scopus 로고    scopus 로고
    • CFD analysis of ventilation efficiency around an elevated highway using visitation frequency and purging flow rate
    • Huang H., Ooka R., Kato S., and Jiang T. CFD analysis of ventilation efficiency around an elevated highway using visitation frequency and purging flow rate. Wind and Structure 9 4 (2006) 297-313
    • (2006) Wind and Structure , vol.9 , Issue.4 , pp. 297-313
    • Huang, H.1    Ooka, R.2    Kato, S.3    Jiang, T.4
  • 14
    • 0020940765 scopus 로고
    • The use of moments for ventilation assessing air quality in ventilated room
    • Sandberg M. The use of moments for ventilation assessing air quality in ventilated room. Building and Environment 18 4 (1983) 181-197
    • (1983) Building and Environment , vol.18 , Issue.4 , pp. 181-197
    • Sandberg, M.1
  • 16
    • 27644571197 scopus 로고    scopus 로고
    • Wind tunnel simulation studies on dispersion at urban street canyons and intersections-a review
    • Ahmad K., Khare M., and Chaudhry K. Wind tunnel simulation studies on dispersion at urban street canyons and intersections-a review. Journal of Wind Engineering and Industrial Aerodynamics 93 9 (2005) 697-717
    • (2005) Journal of Wind Engineering and Industrial Aerodynamics , vol.93 , Issue.9 , pp. 697-717
    • Ahmad, K.1    Khare, M.2    Chaudhry, K.3
  • 17
    • 0031277128 scopus 로고    scopus 로고
    • Towards the determination of the local purging flow rate
    • Hui S., and Davidson L. Towards the determination of the local purging flow rate. Building and Environment 32 6 (1997) 513-525
    • (1997) Building and Environment , vol.32 , Issue.6 , pp. 513-525
    • Hui, S.1    Davidson, L.2
  • 19
    • 49149102318 scopus 로고    scopus 로고
    • STAR-CD, Methodology, STAR-CD V3.22. Computational Dynamics Limited, 2004.
    • STAR-CD, Methodology, STAR-CD V3.22. Computational Dynamics Limited, 2004.
  • 21
    • 1842560841 scopus 로고    scopus 로고
    • Intercomparison of numerical urban dispersion models. Part I: Street canyon and single building configurations
    • Sahm P., Louka P., Ketzel M., Guilloteau E., and Sini J.-F. Intercomparison of numerical urban dispersion models. Part I: Street canyon and single building configurations. Water, Air and Soil Pollution Focus 2 (2002) 587-601
    • (2002) Water, Air and Soil Pollution , vol.Focus 2 , pp. 587-601
    • Sahm, P.1    Louka, P.2    Ketzel, M.3    Guilloteau, E.4    Sini, J.-F.5
  • 22
    • 0031109655 scopus 로고    scopus 로고
    • Calculation of the flow past a surface-mounted cube with two-layer turbulence models
    • Lakehal D., and Rodi. Calculation of the flow past a surface-mounted cube with two-layer turbulence models. Journal of Wind Engineering and Industrial Aerodynamics 67/68 (1997) 65-78
    • (1997) Journal of Wind Engineering and Industrial Aerodynamics , vol.67-68 , pp. 65-78
    • Lakehal, D.1    Rodi2
  • 23
    • 49149120738 scopus 로고    scopus 로고
    • Murakami S, Mochida A, Hayashi Y. Modification of production terms in k-ε model to remove overestimate of k value around windward corner. In: The 10th wind engineering symposium of Japan; 1988. p. 199-201 (in Japanese).
    • Murakami S, Mochida A, Hayashi Y. Modification of production terms in k-ε model to remove overestimate of k value around windward corner. In: The 10th wind engineering symposium of Japan; 1988. p. 199-201 (in Japanese).
  • 24
    • 20344365591 scopus 로고    scopus 로고
    • Wind tunnel modeling of urban building exposure to outdoor pollution
    • Mfula A., Kukadia V., Griffiths R., and Hall D. Wind tunnel modeling of urban building exposure to outdoor pollution. Atmospheric Environment 39 15 (2005) 2737-2745
    • (2005) Atmospheric Environment , vol.39 , Issue.15 , pp. 2737-2745
    • Mfula, A.1    Kukadia, V.2    Griffiths, R.3    Hall, D.4
  • 25
    • 0030304727 scopus 로고    scopus 로고
    • Wind tunnel simulation of plume dispersion through groups of obstacles
    • Davidson M., Snyder W., Lawson R., and Hunt J. Wind tunnel simulation of plume dispersion through groups of obstacles. Atmospheric Environment 30 22 (1996) 3715-3731
    • (1996) Atmospheric Environment , vol.30 , Issue.22 , pp. 3715-3731
    • Davidson, M.1    Snyder, W.2    Lawson, R.3    Hunt, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.