-
1
-
-
33745318441
-
Bilateral multiple pulmonary arteriovenous malformations: Endovascular treatment with the Amplatzer vascular plug
-
Cil B, Canyigit M, Ozkan OS et al (2006) Bilateral multiple pulmonary arteriovenous malformations: Endovascular treatment with the Amplatzer vascular plug. J Vasc Interv Radiol 17:141-145
-
(2006)
J Vasc Interv Radiol
, vol.17
, pp. 141-145
-
-
Cil, B.1
Canyigit, M.2
Ozkan, O.S.3
-
2
-
-
26944467540
-
Endovascular treatment of an internal iliac artery aneurysm using a nitinol vascular occlusion plug
-
Diehm N, Kickuth R, Silvestro A et al (2005) Endovascular treatment of an internal iliac artery aneurysm using a nitinol vascular occlusion plug. J Endovasc Ther 12:616-619
-
(2005)
J Endovasc Ther
, vol.12
, pp. 616-619
-
-
Diehm, N.1
Kickuth, R.2
Silvestro, A.3
-
3
-
-
34249019493
-
Transcatheter closure of coronary arterial fistulas using the new Amplatzer vascular plug
-
Fischer G, Apostolopoulou SC, Rammos S et al (2007) Transcatheter closure of coronary arterial fistulas using the new Amplatzer vascular plug. Cardiol Young 17:283-287
-
(2007)
Cardiol Young
, vol.17
, pp. 283-287
-
-
Fischer, G.1
Apostolopoulou, S.C.2
Rammos, S.3
-
4
-
-
33748893587
-
Transcatheter closure of patent ductus venosus with the Amplatzer vascular plug in twin brothers
-
Gillespie MJ, Golden A, Sivarajan VB et al (2006) Transcatheter closure of patent ductus venosus with the Amplatzer vascular plug in twin brothers. Pediatr Cardiol 27:142-145
-
(2006)
Pediatr Cardiol
, vol.27
, pp. 142-145
-
-
Gillespie, M.J.1
Golden, A.2
Sivarajan, V.B.3
-
5
-
-
4544388023
-
New device for percutaneous closure of aortopulmonary collaterals
-
Hijazi ZM (2004) New device for percutaneous closure of aortopulmonary collaterals. Catheter Cardiovasc Interv 63:482-485
-
(2004)
Catheter Cardiovasc Interv
, vol.63
, pp. 482-485
-
-
Hijazi, Z.M.1
-
6
-
-
30344441775
-
Evaluation of the Amplatzer vascular plug for embolization of peripheral vascular malformations associated with congenital heart disease
-
Hill SL, Hijazi ZM, Hellenbrand WE et al (2006) Evaluation of the Amplatzer vascular plug for embolization of peripheral vascular malformations associated with congenital heart disease. Catheter Cardiovasc Interv 67:113-119
-
(2006)
Catheter Cardiovasc Interv
, vol.67
, pp. 113-119
-
-
Hill, S.L.1
Hijazi, Z.M.2
Hellenbrand, W.E.3
-
7
-
-
34247523171
-
Dual use of an Amplatzer device in the transcatheter embolization of a large high-flow renal arteriovenous fistula
-
Idowu O, Barodawala F, Nemeth A et al (2007) Dual use of an Amplatzer device in the transcatheter embolization of a large high-flow renal arteriovenous fistula. J Vasc Interv Radiol 18:671-676
-
(2007)
J Vasc Interv Radiol
, vol.18
, pp. 671-676
-
-
Idowu, O.1
Barodawala, F.2
Nemeth, A.3
-
8
-
-
33745320852
-
Use of the Amplatzer vascular plug for embolization of a large retroperitoneal shunt during transjugular intrahepatic portosystemic shunt creation for gastric variceal bleeding
-
Kessler J, Trerotola SO (2006) Use of the Amplatzer vascular plug for embolization of a large retroperitoneal shunt during transjugular intrahepatic portosystemic shunt creation for gastric variceal bleeding. J Vasc Interv Radiol 17:135-140
-
(2006)
J Vasc Interv Radiol
, vol.17
, pp. 135-140
-
-
Kessler, J.1
Trerotola, S.O.2
-
9
-
-
41049102183
-
Interventional treatment of a symptomatic neonatal hepatic cavernous hemangioma using the Amplatzer vascular plug
-
Oct 6 (Epub ahead of print) DOI 10.1007/s00270-006-0123-7
-
Kretschmar O, Knirsch W, Bernet V (2006) Interventional treatment of a symptomatic neonatal hepatic cavernous hemangioma using the Amplatzer vascular plug. Cardiovasc Intervent Radiol Oct 6 (Epub ahead of print) DOI 10.1007/s00270-006-0123-7
-
(2006)
Cardiovasc Intervent Radiol
-
-
Kretschmar, O.1
Knirsch, W.2
Bernet, V.3
-
10
-
-
33646046807
-
Successful closure of a giant true saphenous vein graft aneurysm using the Amplatzer vascular plug
-
Mylonas I, Sakata Y, Salinger MH et al (2006) Successful closure of a giant true saphenous vein graft aneurysm using the Amplatzer vascular plug. Catheter Cardiovasc Interv 67:611-616
-
(2006)
Catheter Cardiovasc Interv
, vol.67
, pp. 611-616
-
-
Mylonas, I.1
Sakata, Y.2
Salinger, M.H.3
-
12
-
-
33746428501
-
A new device for vascular embolization: Report on case of two pulmonary arteriovenous fistulas embolization using the amplatzer vascular plug
-
Rossi M, Rebonato A, Greco L et al (2006) A new device for vascular embolization: Report on case of two pulmonary arteriovenous fistulas embolization using the amplatzer vascular plug. Cardiovasc Intervent Radiol 29:902-906
-
(2006)
Cardiovasc Intervent Radiol
, vol.29
, pp. 902-906
-
-
Rossi, M.1
Rebonato, A.2
Greco, L.3
-
13
-
-
33846994054
-
Successful use of a new Amplatzer vascular plug for percutaneous closure of a large aortopulmonary collateral artery in a pulmonary atresia with ventricular septal defect prior to complete repair
-
Tissot C, da Cruz E, Beghetti M et al (2007) Successful use of a new Amplatzer vascular plug for percutaneous closure of a large aortopulmonary collateral artery in a pulmonary atresia with ventricular septal defect prior to complete repair. Int J Cardiol 116:e39-41
-
(2007)
Int J Cardiol
, vol.116
-
-
Tissot, C.1
da Cruz, E.2
Beghetti, M.3
-
15
-
-
38149044079
-
Use of the Amplatzer vascular plug(R) for treatment of coronary steal
-
Weinberg N, French WJ, Shavelle DM (2007) Use of the Amplatzer vascular plug(R) for treatment of coronary steal. Int J Cardiol 124:109-111
-
(2007)
Int J Cardiol
, vol.124
, pp. 109-111
-
-
Weinberg, N.1
French, W.J.2
Shavelle, D.M.3
-
16
-
-
33947498742
-
Vascular percutaneous transcatheter embolisation with a new device: Amplatzer vascular plug
-
Ferro C, Petrocelli F, Rossi UG et al (2007) Vascular percutaneous transcatheter embolisation with a new device: Amplatzer vascular plug. Radiol Med (Torino) 112:239-251
-
(2007)
Radiol Med (Torino)
, vol.112
, pp. 239-251
-
-
Ferro, C.1
Petrocelli, F.2
Rossi, U.G.3
-
17
-
-
29144457562
-
Amplatzer vascular plug to occlude the internal iliac arteries in patients undergoing aortoiliac aneurysm repair
-
Ha CD, Calcagno D (2005) Amplatzer vascular plug to occlude the internal iliac arteries in patients undergoing aortoiliac aneurysm repair. J Vasc Surg 42:1058-1062
-
(2005)
J Vasc Surg
, vol.42
, pp. 1058-1062
-
-
Ha, C.D.1
Calcagno, D.2
-
18
-
-
34548223668
-
Internal iliac artery embolization before endovascular repair of aortoiliac aneurysms with a nitinol vascular occlusion plug
-
Kickuth R, Dick F, Triller J et al (2007) Internal iliac artery embolization before endovascular repair of aortoiliac aneurysms with a nitinol vascular occlusion plug. J Vasc Interv Radiol 18:1081-1087
-
(2007)
J Vasc Interv Radiol
, vol.18
, pp. 1081-1087
-
-
Kickuth, R.1
Dick, F.2
Triller, J.3
-
19
-
-
33744720381
-
Complex thoracoabdominal aortic aneurysms: Endovascular exclusion with visceral revascularization
-
Black SA, Wolfe JH, Clark M et al (2006) Complex thoracoabdominal aortic aneurysms: Endovascular exclusion with visceral revascularization. J Vasc Surg 43:1081-1089
-
(2006)
J Vasc Surg
, vol.43
, pp. 1081-1089
-
-
Black, S.A.1
Wolfe, J.H.2
Clark, M.3
-
20
-
-
0031978889
-
Common iliac artery aneurysms in patients with abdominal aortic aneurysms
-
Armon MP, Wenham PW, Whitaker SC et al (1998) Common iliac artery aneurysms in patients with abdominal aortic aneurysms. Eur J Vasc Endovasc Surg 15:255-257
-
(1998)
Eur J Vasc Endovasc Surg
, vol.15
, pp. 255-257
-
-
Armon, M.P.1
Wenham, P.W.2
Whitaker, S.C.3
-
21
-
-
33744769140
-
Intentional coverage of the left subclavian artery during endovascular stent graft repair for thoracic aortic disease
-
Caronno R, Piffaretti G, Tozzi M et al (2006) Intentional coverage of the left subclavian artery during endovascular stent graft repair for thoracic aortic disease. Surg Endosc 20:915-918
-
(2006)
Surg Endosc
, vol.20
, pp. 915-918
-
-
Caronno, R.1
Piffaretti, G.2
Tozzi, M.3
-
22
-
-
0036616575
-
Initial experience with intentional stent-graft coverage of the subclavian artery during endovascular thoracic aortic repairs
-
Gorich J, Asquan Y, Seifarth H et al (2002) Initial experience with intentional stent-graft coverage of the subclavian artery during endovascular thoracic aortic repairs. J Endovasc Ther 9(Suppl 2):II39-43
-
(2002)
J Endovasc Ther
, vol.9
, Issue.SUPPL. 2
-
-
Gorich, J.1
Asquan, Y.2
Seifarth, H.3
-
23
-
-
12144282738
-
Intentional occlusion of the left subclavian artery during stent-graft implantation in the thoracic aorta: Risk and relevance
-
Rehders TC, Petzsch M, Ince H et al (2004) Intentional occlusion of the left subclavian artery during stent-graft implantation in the thoracic aorta: Risk and relevance. J Endovasc Ther 11:659-666
-
(2004)
J Endovasc Ther
, vol.11
, pp. 659-666
-
-
Rehders, T.C.1
Petzsch, M.2
Ince, H.3
-
24
-
-
33845930018
-
Coverage of the left subclavian artery during thoracic endovascular aortic repair
-
discussion 94-5
-
Riesenman PJ, Farber MA, Mendes RR et al (2007) Coverage of the left subclavian artery during thoracic endovascular aortic repair. J Vasc Surg 45:90-94 discussion 94-5
-
(2007)
J Vasc Surg
, vol.45
, pp. 90-94
-
-
Riesenman, P.J.1
Farber, M.A.2
Mendes, R.R.3
-
25
-
-
1342327531
-
A case report of intentional occlusion of an aberrant right subclavian artery during endovascular stent-graft repair of a descending aortic aneurysm
-
Hutton M, Wolf B, Boyne N et al (2004) A case report of intentional occlusion of an aberrant right subclavian artery during endovascular stent-graft repair of a descending aortic aneurysm. Eur J Vasc Endovasc Surg 27:222-224
-
(2004)
Eur J Vasc Endovasc Surg
, vol.27
, pp. 222-224
-
-
Hutton, M.1
Wolf, B.2
Boyne, N.3
-
26
-
-
34248635424
-
Digital embolization due to partially uncovered left subclavian artery post TEVAR: Management with Amplatzer vascular plug occlusion
-
Chaudhuri A, Tibballs J, Nadkarni S et al (2007) Digital embolization due to partially uncovered left subclavian artery post TEVAR: Management with Amplatzer vascular plug occlusion. J Endovasc Ther 14:257-259
-
(2007)
J Endovasc Ther
, vol.14
, pp. 257-259
-
-
Chaudhuri, A.1
Tibballs, J.2
Nadkarni, S.3
-
27
-
-
36049017069
-
Use of the Amplatzer vascular plug as a coil constrainer during endovascular occlusion of a dialysis shunt
-
Owens CA, Bui JT, West DL et al (2007) Use of the Amplatzer vascular plug as a coil constrainer during endovascular occlusion of a dialysis shunt. Cardiovasc Intervent Radiol 30:754-756
-
(2007)
Cardiovasc Intervent Radiol
, vol.30
, pp. 754-756
-
-
Owens, C.A.1
Bui, J.T.2
West, D.L.3
-
28
-
-
33748176359
-
Recurrent rupture of a hypogastric aneurysm caused by spontaneous recanalization of an Amplatzer vascular plug
-
Dorenberg EJ, Hafsahl G, Andersen R et al (2006) Recurrent rupture of a hypogastric aneurysm caused by spontaneous recanalization of an Amplatzer vascular plug. J Vasc Interv Radiol 17:1037-1041
-
(2006)
J Vasc Interv Radiol
, vol.17
, pp. 1037-1041
-
-
Dorenberg, E.J.1
Hafsahl, G.2
Andersen, R.3
|