메뉴 건너뛰기




Volumn 19, Issue 8, 2008, Pages 1196-1201

Percutaneous Transfemoral Hepatic Arterial Infusion Catheter Placement with the Use of a Downsized Coaxial Catheter System: Technical Feasibility Study

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTERIOGRAPHY; ARTICLE; ARTIFICIAL EMBOLISM; CATHETERIZATION; CLINICAL ARTICLE; DOWNSIZED COAXIAL CATHETER SYSTEM; FEASIBILITY STUDY; FEMALE; FOLLOW UP; HUMAN; INDWELLING CATHETER; LIVER CANCER; MALE; PERCUTANEOUS TRANSFEMORAL HEPATIC ARTERIAL INFUSION CATHETER; PRIORITY JOURNAL; SAFETY;

EID: 48949115350     PISSN: 10510443     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jvir.2008.04.024     Document Type: Article
Times cited : (5)

References (25)
  • 1
    • 0035018197 scopus 로고    scopus 로고
    • Complications encountered with a transfemorally placed port-catheter system for hepatic artery chemotherapy infusion
    • Kuroiwa T., Honda H., Yoshimitsu K., et al. Complications encountered with a transfemorally placed port-catheter system for hepatic artery chemotherapy infusion. Cardiovasc Interv Radiol 24 (2001) 90-93
    • (2001) Cardiovasc Interv Radiol , vol.24 , pp. 90-93
    • Kuroiwa, T.1    Honda, H.2    Yoshimitsu, K.3
  • 2
    • 0037247162 scopus 로고    scopus 로고
    • Radiologic placement of side-hole catheter with tip fixation for hepatic arterial infusion chemotherapy
    • Tanaka T., Arai Y., Inaba Y., et al. Radiologic placement of side-hole catheter with tip fixation for hepatic arterial infusion chemotherapy. J Vasc Interv Radiol 14 (2003) 63-68
    • (2003) J Vasc Interv Radiol , vol.14 , pp. 63-68
    • Tanaka, T.1    Arai, Y.2    Inaba, Y.3
  • 3
    • 16244372419 scopus 로고    scopus 로고
    • Efficacy and safety of hepatic artery infusion catheter placement without fixation in the right gastroepiploic artery
    • Hashimoto M., Watanabe O., Takahashi S., Watarai J., Sato T., and Yamamoto Y. Efficacy and safety of hepatic artery infusion catheter placement without fixation in the right gastroepiploic artery. J Vasc Interv Radiol 16 (2005) 465-470
    • (2005) J Vasc Interv Radiol , vol.16 , pp. 465-470
    • Hashimoto, M.1    Watanabe, O.2    Takahashi, S.3    Watarai, J.4    Sato, T.5    Yamamoto, Y.6
  • 4
    • 16244390833 scopus 로고    scopus 로고
    • Percutaneous femoral catheter placement for long-term chemotherapy infusions: preliminary technical results
    • Tajima T., Yoshimitsu K., Kuroiwa T., et al. Percutaneous femoral catheter placement for long-term chemotherapy infusions: preliminary technical results. Am J Roentgenol 184 (2005) 906-914
    • (2005) Am J Roentgenol , vol.184 , pp. 906-914
    • Tajima, T.1    Yoshimitsu, K.2    Kuroiwa, T.3
  • 5
    • 33750363753 scopus 로고    scopus 로고
    • Placement of a long tapered side-hole catheter in the hepatic artery: technical advantages, catheter stability, and arterial patency
    • Seki H., and Shiina M. Placement of a long tapered side-hole catheter in the hepatic artery: technical advantages, catheter stability, and arterial patency. AJR Am J Roentgenol 187 (2006) 1312-1320
    • (2006) AJR Am J Roentgenol , vol.187 , pp. 1312-1320
    • Seki, H.1    Shiina, M.2
  • 7
    • 0034069214 scopus 로고    scopus 로고
    • Liver intraarterial chemotherapy: use of the femoral artery for percutaneous implantation of catheter-port systems
    • Herrmann K.A., Waggershauser T., Sittek H., and Reiser M.F. Liver intraarterial chemotherapy: use of the femoral artery for percutaneous implantation of catheter-port systems. Radiology 215 (2000) 294-299
    • (2000) Radiology , vol.215 , pp. 294-299
    • Herrmann, K.A.1    Waggershauser, T.2    Sittek, H.3    Reiser, M.F.4
  • 8
    • 4043159145 scopus 로고    scopus 로고
    • Hepatic arterial port systems for treatment of liver metastases: factors affecting patency and adverse events
    • Ricke J., Hildebrandt B., Miersch A., et al. Hepatic arterial port systems for treatment of liver metastases: factors affecting patency and adverse events. J Vasc Interv Radiol 15 (2004) 825-833
    • (2004) J Vasc Interv Radiol , vol.15 , pp. 825-833
    • Ricke, J.1    Hildebrandt, B.2    Miersch, A.3
  • 9
    • 0034770932 scopus 로고    scopus 로고
    • Intraarterial chemotherapy of liver metastases: implantation of a microcatheter-port system with use of modified fixed catheter tip technique
    • Irie T. Intraarterial chemotherapy of liver metastases: implantation of a microcatheter-port system with use of modified fixed catheter tip technique. J Vasc Interv Radiol 12 (2001) 1215-1218
    • (2001) J Vasc Interv Radiol , vol.12 , pp. 1215-1218
    • Irie, T.1
  • 10
    • 32844464182 scopus 로고    scopus 로고
    • A new method using J-type long sheath for implantation of indwelling catheters for trans-femoral hepatic arterial infusion
    • Katoh K., Sone M., Nakasato T., and Ehara S. A new method using J-type long sheath for implantation of indwelling catheters for trans-femoral hepatic arterial infusion. Radiat Med 24 (2006) 80-83
    • (2006) Radiat Med , vol.24 , pp. 80-83
    • Katoh, K.1    Sone, M.2    Nakasato, T.3    Ehara, S.4
  • 11
    • 0031884817 scopus 로고    scopus 로고
    • Complications and technical limitations of hepatic arterial infusion catheter placement for chemotherapy
    • Habbe T.G., McCowan T.C., Goertzen T.C., Leveen R.F., Culp W.C., and Tempero M.A. Complications and technical limitations of hepatic arterial infusion catheter placement for chemotherapy. J Vasc Interv Radiol 9 (1998) 233-239
    • (1998) J Vasc Interv Radiol , vol.9 , pp. 233-239
    • Habbe, T.G.1    McCowan, T.C.2    Goertzen, T.C.3    Leveen, R.F.4    Culp, W.C.5    Tempero, M.A.6
  • 12
    • 2442644272 scopus 로고    scopus 로고
    • Complications after percutaneous transaxillary implantation of a catheter for intraarterial chemotherapy of liver tumors: clinical relevance and management in 204 patients
    • Venturini M., Angeli E., Salvioni M., et al. Complications after percutaneous transaxillary implantation of a catheter for intraarterial chemotherapy of liver tumors: clinical relevance and management in 204 patients. AJR Am J Roentgenol 182 (2004) 1417-1426
    • (2004) AJR Am J Roentgenol , vol.182 , pp. 1417-1426
    • Venturini, M.1    Angeli, E.2    Salvioni, M.3
  • 13
    • 1842583235 scopus 로고    scopus 로고
    • Intra-arterial hepatic chemotherapy: management of liver tumors by percutaneous port-a-cath positioning
    • Grosso M., Scarrone A., Pedrazzini F., et al. Intra-arterial hepatic chemotherapy: management of liver tumors by percutaneous port-a-cath positioning. J Exp Clin Cancer Res 22 (2003) 171-175
    • (2003) J Exp Clin Cancer Res , vol.22 , pp. 171-175
    • Grosso, M.1    Scarrone, A.2    Pedrazzini, F.3
  • 14
    • 33746464503 scopus 로고    scopus 로고
    • Complications of transfemoral removal of percutaneous transfemorally implanted port-catheter systems
    • Yahiro Y., Toyota N., Kakizawa H., et al. Complications of transfemoral removal of percutaneous transfemorally implanted port-catheter systems. Cardiovasc Intervent Radiol 29 (2006) 752-755
    • (2006) Cardiovasc Intervent Radiol , vol.29 , pp. 752-755
    • Yahiro, Y.1    Toyota, N.2    Kakizawa, H.3
  • 15
    • 10044241637 scopus 로고    scopus 로고
    • Adjuvant hepatic arterial infusion after curative resection of colorectal liver metastases using removable intra-arterial catheters with shape-memory alloy
    • Tono T., Kanoh T., Ohnishi T., et al. Adjuvant hepatic arterial infusion after curative resection of colorectal liver metastases using removable intra-arterial catheters with shape-memory alloy. J Surg Oncol 88 (2004) 248-255
    • (2004) J Surg Oncol , vol.88 , pp. 248-255
    • Tono, T.1    Kanoh, T.2    Ohnishi, T.3
  • 16
    • 1342266134 scopus 로고    scopus 로고
    • Value of transcatheter arterial embolization with coils and n-butyl cyanoacrylate for long-term hepatic arterial infusion chemotherapy
    • Yamagami T., Kato T., Iida S., Tanaka O., and Nishimura T. Value of transcatheter arterial embolization with coils and n-butyl cyanoacrylate for long-term hepatic arterial infusion chemotherapy. Radiology 230 (2004) 792-802
    • (2004) Radiology , vol.230 , pp. 792-802
    • Yamagami, T.1    Kato, T.2    Iida, S.3    Tanaka, O.4    Nishimura, T.5
  • 17
    • 0036893086 scopus 로고    scopus 로고
    • Using n-butyl cyanoacrylate and the fixed-catheter-tip technique in percutaneous implantation of a port-catheter system in patients undergoing repeated hepatic arterial chemotherapy
    • Yamagami T., Iida S., Kato T., et al. Using n-butyl cyanoacrylate and the fixed-catheter-tip technique in percutaneous implantation of a port-catheter system in patients undergoing repeated hepatic arterial chemotherapy. AJR Am J Roentgenol 179 (2002) 1611-1617
    • (2002) AJR Am J Roentgenol , vol.179 , pp. 1611-1617
    • Yamagami, T.1    Iida, S.2    Kato, T.3
  • 18
    • 0020329095 scopus 로고
    • Pediatric arterial catheterization using a 3.2-French catheter
    • Keane J.F., Fellows K.E., Lang P., et al. Pediatric arterial catheterization using a 3.2-French catheter. Cathet Cardiovasc Diagn 8 (1982) 201-208
    • (1982) Cathet Cardiovasc Diagn , vol.8 , pp. 201-208
    • Keane, J.F.1    Fellows, K.E.2    Lang, P.3
  • 19
    • 0030737899 scopus 로고    scopus 로고
    • Examination of renal donors as outpatients using intraarterial digital subtraction angiography and a pigtail catheter
    • Cardi J.G., Devane A.M., Hawkins I.F., and Newman R. Examination of renal donors as outpatients using intraarterial digital subtraction angiography and a pigtail catheter. AJR Am J Roentgenol 169 (1997) 537-539
    • (1997) AJR Am J Roentgenol , vol.169 , pp. 537-539
    • Cardi, J.G.1    Devane, A.M.2    Hawkins, I.F.3    Newman, R.4
  • 20
    • 0036594543 scopus 로고    scopus 로고
    • Feasibility of early ambulation three hours after transfemoral angiography using a 4 French sheath
    • Ishiyama K., Hashimoto M., Tate E., et al. Feasibility of early ambulation three hours after transfemoral angiography using a 4 French sheath. Nippon Igaku Hoshasen Gakkai Zasshi 62 (2002) 362-365
    • (2002) Nippon Igaku Hoshasen Gakkai Zasshi , vol.62 , pp. 362-365
    • Ishiyama, K.1    Hashimoto, M.2    Tate, E.3
  • 22
    • 0034928114 scopus 로고    scopus 로고
    • A randomised comparison of the use of 4 and 6 F diagnostic catheters: the limits of downsizing
    • Danzi G.B., Capuano C., Sesana M., et al. A randomised comparison of the use of 4 and 6 F diagnostic catheters: the limits of downsizing. Int J Cardiol 79 (2001) 113-117
    • (2001) Int J Cardiol , vol.79 , pp. 113-117
    • Danzi, G.B.1    Capuano, C.2    Sesana, M.3
  • 23
    • 0035491634 scopus 로고    scopus 로고
    • Coronary angiography using 4 or 6 F diagnostic catheters: a prospective, randomized study
    • Lefevre T., Morice M.C., Bonan R., et al. Coronary angiography using 4 or 6 F diagnostic catheters: a prospective, randomized study. J Invas Cardiol 13 (2001) 674-677
    • (2001) J Invas Cardiol , vol.13 , pp. 674-677
    • Lefevre, T.1    Morice, M.C.2    Bonan, R.3
  • 24
    • 34247866438 scopus 로고    scopus 로고
    • Comparison of 4 and 6 F catheters for coronary angiography: real-world modeling
    • Durst R., Lotan C., Nassar H., et al. Comparison of 4 and 6 F catheters for coronary angiography: real-world modeling. Isr Med Assoc J 9 (2007) 290-293
    • (2007) Isr Med Assoc J , vol.9 , pp. 290-293
    • Durst, R.1    Lotan, C.2    Nassar, H.3
  • 25
    • 0029678326 scopus 로고    scopus 로고
    • Standardization of use of 4-F size catheter for selective transcatheter angiography and intervention of abdomen
    • Kiyosue H., Mori H., Matsumoto S., et al. Standardization of use of 4-F size catheter for selective transcatheter angiography and intervention of abdomen. Nippon Igaku Hoshasen Gakkai Zasshi 56 (1996) 32-36
    • (1996) Nippon Igaku Hoshasen Gakkai Zasshi , vol.56 , pp. 32-36
    • Kiyosue, H.1    Mori, H.2    Matsumoto, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.