메뉴 건너뛰기




Volumn 27, Issue 8, 2008, Pages 1203-1209

Use of contrast-enhanced ultrasound imaging to detect the first draining lymph node (FDLN) in a swine model: Correlation of imaging findings with the distance from the injection site to the FDLN

Author keywords

Contrast agent; Lymph node; Sentinel node; Ultrasound

Indexed keywords

BODY FLUIDS; BUBBLES (IN FLUIDS); SULFUR HEXAFLUORIDE; ULTRASONIC IMAGING; ULTRASONICS;

EID: 48949106354     PISSN: 02784297     EISSN: None     Source Type: Journal    
DOI: 10.7863/jum.2008.27.8.1203     Document Type: Article
Times cited : (13)

References (25)
  • 3
    • 0034077059 scopus 로고    scopus 로고
    • Long-term results of a multi-institutional randomized trial comparing prognostic factors and surgical results for intermediate thickness melanomas (1.0 to 4.0 mm). Intergroup Melanoma Surgical Trial
    • Balch CM, Soong S, Ross MI, et al. Long-term results of a multi-institutional randomized trial comparing prognostic factors and surgical results for intermediate thickness melanomas (1.0 to 4.0 mm). Intergroup Melanoma Surgical Trial. Ann Surg Oncol 2000; 7:87-97.
    • (2000) Ann Surg Oncol , vol.7 , pp. 87-97
    • Balch, C.M.1    Soong, S.2    Ross, M.I.3
  • 4
    • 0032977814 scopus 로고    scopus 로고
    • Multi-institutional melanoma lymphatic mapping experience: The prognostic value of sentinel lymph node status in 612 stage I or II melanoma patients
    • Gershenwald JE, Thompson W, Mansfield PF, et al. Multi-institutional melanoma lymphatic mapping experience: the prognostic value of sentinel lymph node status in 612 stage I or II melanoma patients. J Clin Oncol 1999; 17:976-983.
    • (1999) J Clin Oncol , vol.17 , pp. 976-983
    • Gershenwald, J.E.1    Thompson, W.2    Mansfield, P.F.3
  • 5
    • 1342308744 scopus 로고    scopus 로고
    • Sentinel lymph nodes in a swine model with melanoma: Contrast-enhanced lymphatic US
    • Goldberg BB, Merton DA, Liu JB, et al. Sentinel lymph nodes in a swine model with melanoma: contrast-enhanced lymphatic US. Radiology 2004; 230:727-734.
    • (2004) Radiology , vol.230 , pp. 727-734
    • Goldberg, B.B.1    Merton, D.A.2    Liu, J.B.3
  • 6
    • 21244491980 scopus 로고    scopus 로고
    • Contrast-enhanced sonographic imaging of lymphatic channels and sentinel lymph nodes
    • Goldberg BB, Merton DA, Liu JB, Murphy G, Forsberg F. Contrast-enhanced sonographic imaging of lymphatic channels and sentinel lymph nodes. J Ultrasound Med 2005; 24:953-965.
    • (2005) J Ultrasound Med , vol.24 , pp. 953-965
    • Goldberg, B.B.1    Merton, D.A.2    Liu, J.B.3    Murphy, G.4    Forsberg, F.5
  • 8
    • 0036236515 scopus 로고    scopus 로고
    • Sentinel lymph node imaging with microbubble ultrasound contrast material
    • Mattrey RF, Kono Y, Baker K, Peterson T. Sentinel lymph node imaging with microbubble ultrasound contrast material. Acad Radiol 2002; 9(suppl 1):S231-S235.
    • (2002) Acad Radiol , vol.9 , Issue.SUPPL. 1
    • Mattrey, R.F.1    Kono, Y.2    Baker, K.3    Peterson, T.4
  • 9
    • 33645226961 scopus 로고    scopus 로고
    • The sentinel node in gynaecological malignancies
    • Balega J, Van Trappen PO. The sentinel node in gynaecological malignancies. Cancer Imaging 2006; 6:7-15.
    • (2006) Cancer Imaging , vol.6 , pp. 7-15
    • Balega, J.1    Van Trappen, P.O.2
  • 10
    • 24344473846 scopus 로고    scopus 로고
    • What's new in the management of penile cancer?
    • Busby JE, Pettaway CA. What's new in the management of penile cancer? Curr Opin Urol 2005; 15:350-357.
    • (2005) Curr Opin Urol , vol.15 , pp. 350-357
    • Busby, J.E.1    Pettaway, C.A.2
  • 13
    • 27744447254 scopus 로고    scopus 로고
    • Reproducibility of lymphoscintigraphy for lymphatic mapping in patients with penile carcinoma
    • Kroon BK, Valdés Olmos RA, van Tinteren H, Nieweg OE, Horenblas S. Reproducibility of lymphoscintigraphy for lymphatic mapping in patients with penile carcinoma. J Urol 2005; 174:2214-2217.
    • (2005) J Urol , vol.174 , pp. 2214-2217
    • Kroon, B.K.1    Valdés Olmos, R.A.2    van Tinteren, H.3    Nieweg, O.E.4    Horenblas, S.5
  • 15
    • 4444321866 scopus 로고    scopus 로고
    • Imaging the lymphatic system: Possibilities and clinical applications
    • Clement O, Luciani A. Imaging the lymphatic system: possibilities and clinical applications. Eur Radiol 2004; 14:1498-1507.
    • (2004) Eur Radiol , vol.14 , pp. 1498-1507
    • Clement, O.1    Luciani, A.2
  • 16
    • 33746421108 scopus 로고    scopus 로고
    • Contrast-assisted ultrasound for sentinel lymph node detection in spontaneously arising canine head and neck tumors
    • Lurie DM, Seguin B, Schneider PD, Verstraete FJ, Wisner ER. Contrast-assisted ultrasound for sentinel lymph node detection in spontaneously arising canine head and neck tumors. Invest Radiol 2006; 41:415-421.
    • (2006) Invest Radiol , vol.41 , pp. 415-421
    • Lurie, D.M.1    Seguin, B.2    Schneider, P.D.3    Verstraete, F.J.4    Wisner, E.R.5
  • 17
    • 0036750341 scopus 로고    scopus 로고
    • New method of sentinel node identification with ultrasonography using albumin as contrast agent: A study in pigs
    • Omoto K, Mizunuma H, Ogura S, et al. New method of sentinel node identification with ultrasonography using albumin as contrast agent: a study in pigs. Ultrasound Med Biol 2002; 28:1115-1122.
    • (2002) Ultrasound Med Biol , vol.28 , pp. 1115-1122
    • Omoto, K.1    Mizunuma, H.2    Ogura, S.3
  • 18
    • 0036337219 scopus 로고    scopus 로고
    • Contrast enhanced intermittent power Doppler ultrasound with sub-micron bubbles for sentinel node detection
    • Wisner ER, Ferrara K, Gabe JD, et al. Contrast enhanced intermittent power Doppler ultrasound with sub-micron bubbles for sentinel node detection. Acad Radiol 2002; 9(suppl 2):S389-S391.
    • (2002) Acad Radiol , vol.9 , Issue.SUPPL. 2
    • Wisner, E.R.1    Ferrara, K.2    Gabe, J.D.3
  • 20
    • 85027233214 scopus 로고    scopus 로고
    • EPARs for authorised medicinal products for human use: SonoVue
    • European Medicines Agency website
    • European Medicines Agency. EPARs for authorised medicinal products for human use: SonoVue. Annex I: summary of product characteristics. European Medicines Agency website. http://www.emea.europa.eu/humandocs/humans/epar/ sonovue/sonovue.htm.
    • Annex I: Summary of product characteristics
  • 21
    • 2142760005 scopus 로고    scopus 로고
    • Gray-scale liver enhancement with Sonazoid (NC 100100), a novel ultrasound contrast agent: Detection of hepatic tumors in a rabbit model
    • Watanabe R, Matsumura M, Chen CJ, Kaneda Y, Ishihara M, Fujimaki M. Gray-scale liver enhancement with Sonazoid (NC 100100), a novel ultrasound contrast agent: detection of hepatic tumors in a rabbit model. Biol Pharm Bull 2003; 26:1272-1277.
    • (2003) Biol Pharm Bull , vol.26 , pp. 1272-1277
    • Watanabe, R.1    Matsumura, M.2    Chen, C.J.3    Kaneda, Y.4    Ishihara, M.5    Fujimaki, M.6
  • 22
    • 85027233214 scopus 로고    scopus 로고
    • EPARs for authorised medicinal products for human use: Luminity
    • European Medicines Agency website
    • European Medicines Agency. EPARs for authorised medicinal products for human use: Luminity. Annex I: summary of product characteristics. European Medicines Agency website. http://www.emea.europa.eu/humandocs/humans/epar/ luminity/luminity.htm.
    • Annex I: Summary of product characteristics
  • 23
    • 85027229213 scopus 로고    scopus 로고
    • Daiichi Sankyo Co Ltd. Ultrasound contrast medium Sonazoid® gets import approval. Daiichi Sankyo Co Ltd website. http://www.daiichisankyo.com/ news/yymmdd_nn.html?b_newsrelease_n1_eng.detail[id]=223.3&b_ newsrelease_n1_eng.year_selector[id]=223.3&b_ newsrelease_n1_eng. category_selector[id]=223.3.
    • Daiichi Sankyo Co Ltd. Ultrasound contrast medium Sonazoid® gets import approval. Daiichi Sankyo Co Ltd website. http://www.daiichisankyo.com/ news/yymmdd_nn.html?b_newsrelease_n1_eng.detail[id]=223.3&b_ newsrelease_n1_eng.year_selector[id]=223.3&b_ newsrelease_n1_eng. category_selector[id]=223.3.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.