메뉴 건너뛰기




Volumn 112, Issue 2, 2007, Pages 183-189

Implantation of the femoral stem into a bed of titanium granules using vibration: A pilot study of a new method for prosthetic fixation in 5 patients followed for up to 15 years

Author keywords

[No Author keywords available]

Indexed keywords

TITANIUM;

EID: 48949097507     PISSN: 03009734     EISSN: None     Source Type: Journal    
DOI: 10.3109/2000-1967-192     Document Type: Article
Times cited : (25)

References (11)
  • 1
    • 0015295233 scopus 로고    scopus 로고
    • Charnley J. The long-term results of low-friction arthroplasty of the hip performed as a primary intervention (1972). J Bone Joint Surg Br. 54: 61-76.
    • Charnley J. The long-term results of low-friction arthroplasty of the hip performed as a primary intervention (1972). J Bone Joint Surg Br. 54: 61-76.
  • 3
    • 0027506453 scopus 로고
    • A quantitative study of bone and soft tissues in cementless porous-coated acetabular components retrieved at autopsy
    • Pidhorz L E, Urban R M, Jacobs J J, Sumner D R, Galante J O (1993). A quantitative study of bone and soft tissues in cementless porous-coated acetabular components retrieved at autopsy. J Arthroplasty. 8: 213-25.
    • (1993) J Arthroplasty , vol.8 , pp. 213-225
    • Pidhorz, L.E.1    Urban, R.M.2    Jacobs, J.J.3    Sumner, D.R.4    Galante, J.O.5
  • 4
    • 33745271282 scopus 로고    scopus 로고
    • Packing circles under variable spatial constraints: A vibration control approach
    • Kakazu Y, Wada M, Sato T eds, IOS Press, Amsterdam. pp
    • Arai M, Miyazawa T, Minagawa M (1998). Packing circles under variable spatial constraints: a vibration control approach. In: Kakazu Y, Wada M, Sato T (eds); Intelligent Autonomous Systems IAS-5; IOS Press, Amsterdam. pp 727-34.
    • (1998) Intelligent Autonomous Systems IAS-5 , pp. 727-734
    • Arai, M.1    Miyazawa, T.2    Minagawa, M.3
  • 5
    • 0035190728 scopus 로고    scopus 로고
    • Morphometric examination of straight, tapered titanium stems: A retrieval study
    • Bohm G, Lintner F, Auterith A, Lester D K, Zweymuller KA(2001). Morphometric examination of straight, tapered titanium stems: a retrieval study. Clin Orthop 393: 13-24.
    • (2001) Clin Orthop , vol.393 , pp. 13-24
    • Bohm, G.1    Lintner, F.2    Auterith, A.3    Lester, D.K.4    Zweymuller, K.A.5
  • 6
    • 85130085287 scopus 로고    scopus 로고
    • Urban R M, Jacobs J J, Gilbert J L, Galante J O. Migration of corrosion products from modular hip prostheses. Particle microanalysis and histopathological findings (1994). J Bone Joint Surg Am 76: 1345-59.
    • Urban R M, Jacobs J J, Gilbert J L, Galante J O. Migration of corrosion products from modular hip prostheses. Particle microanalysis and histopathological findings (1994). J Bone Joint Surg Am 76: 1345-59.
  • 7
    • 0025900565 scopus 로고
    • Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs
    • Buser D, Schenk R K, Steinemann S, Fiorellini J P, Fox C H, Stich H (1991). Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs. J Biomed Mater Res 25: 889-902.
    • (1991) J Biomed Mater Res , vol.25 , pp. 889-902
    • Buser, D.1    Schenk, R.K.2    Steinemann, S.3    Fiorellini, J.P.4    Fox, C.H.5    Stich, H.6
  • 8
    • 0030110849 scopus 로고    scopus 로고
    • Bone response to surface-modified titanium implants: Studies on the early tissue response to machined and electropolished implants with different oxide thicknesses
    • Larsson C, Thomsen P, Aronsson B O, Rodahl M, Lausmaa J, Kasemo B, Ericson LE (1996). Bone response to surface-modified titanium implants: studies on the early tissue response to machined and electropolished implants with different oxide thicknesses. Biomaterials 17: 605-16.
    • (1996) Biomaterials , vol.17 , pp. 605-616
    • Larsson, C.1    Thomsen, P.2    Aronsson, B.O.3    Rodahl, M.4    Lausmaa, J.5    Kasemo, B.6    Ericson, L.E.7
  • 10
    • 1842406624 scopus 로고    scopus 로고
    • The theory of early loosening of hip prostheses
    • Mjöberg B (1997). The theory of early loosening of hip prostheses. Orthopedics 20: 1169-75.
    • (1997) Orthopedics , vol.20 , pp. 1169-1175
    • Mjöberg, B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.