메뉴 건너뛰기




Volumn 21, Issue 4, 2008, Pages 307-311

Twenty-year follow-up of metal-ceramic single crowns: A retrospective study

Author keywords

[No Author keywords available]

Indexed keywords

ALLOY;

EID: 48749114754     PISSN: 08932174     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (60)

References (14)
  • 1
    • 0027604533 scopus 로고
    • Artificial crowns and fixed partial dentures 18 to 23 years after placement
    • Palmqvist S, Swartz B. Artificial crowns and fixed partial dentures 18 to 23 years after placement. Int J Prosthodont 1993;6:279-285.
    • (1993) Int J Prosthodont , vol.6 , pp. 279-285
    • Palmqvist, S.1    Swartz, B.2
  • 2
    • 0033223147 scopus 로고    scopus 로고
    • A 10-year longitudinal study of fixed prosthodontics: Clinical characteristics and outcome of single-unit metal-ceramic crowns
    • Walton TR. A 10-year longitudinal study of fixed prosthodontics: Clinical characteristics and outcome of single-unit metal-ceramic crowns. Int J Prosthodont 1999;12:519-526.
    • (1999) Int J Prosthodont , vol.12 , pp. 519-526
    • Walton, T.R.1
  • 4
    • 0031254728 scopus 로고    scopus 로고
    • A 10-year follow-up study of fixed metal ceramic prosthodontics
    • NäpänkangasR, Salonen MAM, Raustia AM. A 10-year follow-up study of fixed metal ceramic prosthodontics. J Oral Rehabil 1997;24:713-717.
    • (1997) J Oral Rehabil , vol.24 , pp. 713-717
    • Näpänkangas, R.1    Salonen, M.A.M.2    Raustia, A.M.3
  • 5
    • 12244286788 scopus 로고    scopus 로고
    • A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years. III. Conventional FPDs
    • Tan K, Pjetursson BE, Land NP, Chan ESY. A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years. III. Conventional FPDs. Clin Oral Implants Res 2004;15:654-666.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 654-666
    • Tan, K.1    Pjetursson, B.E.2    Land, N.P.3    Chan, E.S.Y.4
  • 6
    • 0034568935 scopus 로고    scopus 로고
    • Influence of previous restoration of the tooth on prognosis of crowns with dowels
    • Näpänkangas R, Salonen MAM, Raustia AM. Influence of previous restoration of the tooth on prognosis of crowns with dowels. J Oral Rehabil 2000;27:1042-1046.
    • (2000) J Oral Rehabil , vol.27 , pp. 1042-1046
    • Näpänkangas, R.1    Salonen, M.A.M.2    Raustia, A.M.3
  • 7
    • 0028390054 scopus 로고
    • Multivariate analyses of factors influencing the longevity of fixed partial dentures, retainers, and abutments
    • Palmqvist S, Söderfeldt B. Multivariate analyses of factors influencing the longevity of fixed partial dentures, retainers, and abutments. J Prosthet Dent 1994;71:245-250.
    • (1994) J Prosthet Dent , vol.71 , pp. 245-250
    • Palmqvist, S.1    Söderfeldt, B.2
  • 8
    • 0026235258 scopus 로고
    • Prevalence of apical periodontitis, crowned teeth and teeth with posts in a Swedish population
    • Eckerbom M, Magnusson T, Martinsson T. Prevalence of apical periodontitis, crowned teeth and teeth with posts in a Swedish population. Endod Dent Traumatol 1991;7:214-220.
    • (1991) Endod Dent Traumatol , vol.7 , pp. 214-220
    • Eckerbom, M.1    Magnusson, T.2    Martinsson, T.3
  • 9
    • 0026877356 scopus 로고
    • Provision of crowns in Scotland- A ten-year longitudinal study
    • Fyffe HE. Provision of crowns in Scotland- A ten-year longitudinal study. Community Dent Health 1992;9:159-164.
    • (1992) Community Dent Health , vol.9 , pp. 159-164
    • Fyffe, H.E.1
  • 10
    • 0027356917 scopus 로고
    • Effect of post design on resistance to fracture of endodontically treated teeth with complete crowns
    • Assif D, Bitenski A, Pilo R, Oren E. Effect of post design on resistance to fracture of endodontically treated teeth with complete crowns. J Prosthet Dent 1993;69:36-40.
    • (1993) J Prosthet Dent , vol.69 , pp. 36-40
    • Assif, D.1    Bitenski, A.2    Pilo, R.3    Oren, E.4
  • 12
    • 0021464874 scopus 로고
    • Clinically significant factors in dowel design
    • Sorensen JA, Martinoff JT. Clinically significant factors in dowel design. J Prosthet Dent 1984;52:28-35.
    • (1984) J Prosthet Dent , vol.52 , pp. 28-35
    • Sorensen, J.A.1    Martinoff, J.T.2
  • 14
    • 0031309838 scopus 로고    scopus 로고
    • Mechanical properties of endodontic posts
    • Lambjerg-Hansen H, Asmussen E. Mechanical properties of endodontic posts. J Oral Rehabil 1997;24:882-887.
    • (1997) J Oral Rehabil , vol.24 , pp. 882-887
    • Lambjerg-Hansen, H.1    Asmussen, E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.