메뉴 건너뛰기




Volumn 26, Issue 7, 2008, Pages 943-953

Distortion correction for a double inversion-recovery sequence with an echo-planar imaging readout

Author keywords

Distortion correction; Double inversion recovery; Echo planar imaging; MRI; Reversed gradient method

Indexed keywords

ARTICLE; DOUBLE INVERSION RECOVERY ECHO PLANAR IMAGING; ECHO PLANAR IMAGING; FUNCTIONAL MAGNETIC RESONANCE IMAGING; GEOMETRY; GRAY MATTER; IMAGE DISPLAY; NEUROIMAGING; PRIORITY JOURNAL; SENSITIVITY AND SPECIFICITY; WHITE MATTER;

EID: 48549096528     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mri.2008.02.007     Document Type: Article
Times cited : (3)

References (12)
  • 1
    • 0025630001 scopus 로고
    • Brain magnetic resonance imaging with contrast dependent on blood oxygenation
    • Ogawa S., Lee T.M., Kay A.R., and Tank D.W. Brain magnetic resonance imaging with contrast dependent on blood oxygenation. Proc Natl Acad Sci U S A 87 (1990) 9868-9872
    • (1990) Proc Natl Acad Sci U S A , vol.87 , pp. 9868-9872
    • Ogawa, S.1    Lee, T.M.2    Kay, A.R.3    Tank, D.W.4
  • 2
    • 0028558724 scopus 로고
    • Technical note: use of a double inversion recovery pulse sequence to image selectively grey or white brain matter
    • Redpath T.W., and Smith F.W. Technical note: use of a double inversion recovery pulse sequence to image selectively grey or white brain matter. Br J Radiol 67 (1994) 1258-1263
    • (1994) Br J Radiol , vol.67 , pp. 1258-1263
    • Redpath, T.W.1    Smith, F.W.2
  • 5
    • 0026925939 scopus 로고
    • A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities
    • Chang H., and Fitzpatrick J.M. A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities. IEEE Trans Med Imaging 11 (1992) 319-329
    • (1992) IEEE Trans Med Imaging , vol.11 , pp. 319-329
    • Chang, H.1    Fitzpatrick, J.M.2
  • 7
    • 1842590302 scopus 로고    scopus 로고
    • Correction of spatial distortion in EPI due to inhomogeneous static magnetic fields using the reversed gradient method
    • Morgan P.S., Bowtell R.W., McIntyre D.J.O., and Worthington B.S. Correction of spatial distortion in EPI due to inhomogeneous static magnetic fields using the reversed gradient method. J Magn Reson Imaging 19 (2004) 499-507
    • (2004) J Magn Reson Imaging , vol.19 , pp. 499-507
    • Morgan, P.S.1    Bowtell, R.W.2    McIntyre, D.J.O.3    Worthington, B.S.4
  • 9
    • 35048867303 scopus 로고    scopus 로고
    • Impact of incidental magnetization transfer effects on inversion-recovery sequences that use a fast spin-echo readout
    • Meara S.J.P., and Barker G.J. Impact of incidental magnetization transfer effects on inversion-recovery sequences that use a fast spin-echo readout. Magn Reson Med 58 (2007) 825-829
    • (2007) Magn Reson Med , vol.58 , pp. 825-829
    • Meara, S.J.P.1    Barker, G.J.2
  • 11
    • 0036335681 scopus 로고    scopus 로고
    • A model-based method for retrospective correction of geometric distortions in diffusion-weighted EPI
    • Andersson J.L.R., and Skare S. A model-based method for retrospective correction of geometric distortions in diffusion-weighted EPI. NeuroImage 16 (2002) 177-199
    • (2002) NeuroImage , vol.16 , pp. 177-199
    • Andersson, J.L.R.1    Skare, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.