메뉴 건너뛰기




Volumn 31, Issue SUPPL.2, 2008, Pages

Unusual presentation of infected vertebroplasty with delayed cement dislodgment in an immunocompromised patient: Case report and review of literature

Author keywords

Cement; Complication; Infected spondylitis; Polymethylmethacrylate; Vertebroplasty

Indexed keywords

CEFUROXIME; POLY(METHYL METHACRYLATE);

EID: 48449103258     PISSN: 01741551     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00270-007-9234-z     Document Type: Article
Times cited : (23)

References (17)
  • 2
    • 0031545893 scopus 로고    scopus 로고
    • Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: Technical aspects.
    • ME Jensen AJ Evans JM Mathis 1997 Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: Technical aspects. AJNR Am J Neuroradiol 18 1897 1904
    • (1997) AJNR Am J Neuroradiol , vol.18 , pp. 1897-1904
    • Jensen, M.E.1    Evans, A.J.2    Mathis, J.M.3
  • 3
    • 3543086793 scopus 로고    scopus 로고
    • Serious pyogenic spondylitis following vertebroplasty: A case report.
    • SW Yu WJ Chen WC Lin 2004 Serious pyogenic spondylitis following vertebroplasty: A case report. Spine 29 E209 211
    • (2004) Spine , vol.29 , pp. 209-211
    • Yu, S.W.1    Chen, W.J.2    Lin, W.C.3
  • 4
    • 26944492864 scopus 로고    scopus 로고
    • Infected vertebroplasty. Report of two cases and review of the literature.
    • DH Walker P Mummaneni GE Rodts Jr 2004 Infected vertebroplasty. Report of two cases and review of the literature. Neurosurg Focus 17 E6
    • (2004) Neurosurg Focus , vol.17 , pp. 6
    • Walker, D.H.1    Mummaneni, P.2    Rodts Jr., G.E.3
  • 5
    • 33750373349 scopus 로고    scopus 로고
    • Infected vertebroplasty: Case report and review of literature.
    • HS Vats FE McKiernan 2006 Infected vertebroplasty: Case report and review of literature. Spine 31 E859 862
    • (2006) Spine , vol.31 , pp. 859-862
    • Vats, H.S.1    McKiernan, F.E.2
  • 7
    • 33748876399 scopus 로고    scopus 로고
    • Infected vertebroplasty due to uncommon bacteria solved surgically: A rare and threatening life complication of a common procedure. Report of a case and a review of the literature.
    • M Alfonso Olmos A Silva Gonzalez J Duart Clemente 2006 Infected vertebroplasty due to uncommon bacteria solved surgically: A rare and threatening life complication of a common procedure. Report of a case and a review of the literature. Spine 31 E770 773
    • (2006) Spine , vol.31 , pp. 770-773
    • Alfonso Olmos, M.1    Silva Gonzalez, A.2    Duart Clemente, J.3
  • 8
    • 0036782669 scopus 로고    scopus 로고
    • Paraplegia as a complication of percutaneous vertebroplasty with polymethylmethacrylate: A case report.
    • BJ Lee SR Lee TY Yoo 2002 Paraplegia as a complication of percutaneous vertebroplasty with polymethylmethacrylate: A case report. Spine 27 E419 422
    • (2002) Spine , vol.27 , pp. 419-422
    • Lee, B.J.1    Lee, S.R.2    Yoo, T.Y.3
  • 9
    • 2442519653 scopus 로고    scopus 로고
    • Successful management of a large pulmonary cement embolus after percutaneous vertebroplasty: A case report.
    • K Francois Y Taeymans B Poffyn 2003 Successful management of a large pulmonary cement embolus after percutaneous vertebroplasty: A case report. Spine 28 E424 425
    • (2003) Spine , vol.28 , pp. 424-425
    • Francois, K.1    Taeymans, Y.2    Poffyn, B.3
  • 10
    • 33644852426 scopus 로고    scopus 로고
    • Refracture with cement extrusion following percutaneous vertebroplasty of a large interbody cleft.
    • AL Wagner E Baskurt 2006 Refracture with cement extrusion following percutaneous vertebroplasty of a large interbody cleft. AJNR Am J Neuroradiol 27 230 231
    • (2006) AJNR Am J Neuroradiol , vol.27 , pp. 230-231
    • Wagner, A.L.1    Baskurt, E.2
  • 11
    • 2442430895 scopus 로고    scopus 로고
    • Polymethylmethacrylate cement dislodgment following percutaneous vertebroplasty: A case report.
    • TT Tsai WJ Chen PL Lai 2003 Polymethylmethacrylate cement dislodgment following percutaneous vertebroplasty: A case report. Spine 28 E457 460
    • (2003) Spine , vol.28 , pp. 457-460
    • Tsai, T.T.1    Chen, W.J.2    Lai, P.L.3
  • 13
    • 0031172484 scopus 로고    scopus 로고
    • Properties of acrylic bone cement: State of the art review.
    • G Lewis 1997 Properties of acrylic bone cement: State of the art review. J Biomed Mater Res 38 155 182
    • (1997) J Biomed Mater Res , vol.38 , pp. 155-182
    • Lewis, G.1
  • 14
    • 0037096636 scopus 로고    scopus 로고
    • Biomechanical evaluation of an injectable calcium phosphate cement for vertebroplasty.
    • TH Lim GT Brebach SM Renner 2002 Biomechanical evaluation of an injectable calcium phosphate cement for vertebroplasty. Spine 27 1297 1302
    • (2002) Spine , vol.27 , pp. 1297-1302
    • Lim, T.H.1    Brebach, G.T.2    Renner, S.M.3
  • 15
    • 27544464928 scopus 로고    scopus 로고
    • Clinical impact and pathogenicity of Acinetobacter.
    • ML Joly-Guillou 2005 Clinical impact and pathogenicity of Acinetobacter. Clin Microbiol Infect 11 868 873
    • (2005) Clin Microbiol Infect , vol.11 , pp. 868-873
    • Joly-Guillou, M.L.1
  • 16
    • 0022975117 scopus 로고
    • Clean air at operation and subsequent sepsis in the joint
    • Lidwell OM (1986) Clean air at operation and subsequent sepsis in the joint. Clin Orthop:91-102
    • (1986) Clin Orthop , pp. 91-102
    • Lidwell, O.M.1
  • 17
    • 0021743306 scopus 로고
    • Antibiotic-loaded acrylic cement: Current concepts
    • Buchholz HW, Elson RA, Heinert K (1984) Antibiotic-loaded acrylic cement: Current concepts. Clin Orthop:96-108
    • (1984) Clin Orthop , pp. 96-108
    • Buchholz, H.W.1    Elson, R.A.2    Heinert, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.