메뉴 건너뛰기




Volumn 128, Issue 8, 2008, Pages 773-781

Surface coating to improve the metal-cement bonding in cemented femur stems

Author keywords

Aseptic loosening; Cemented hip arthroplasty; Debonding; Metal cement interface; Surface coating

Indexed keywords

ALLOY; ALUMINUM; BIOMATERIAL; BONE CEMENT; CHROMIUM; COBALT; METAL; MOLYBDENUM; SILANE; SILICATE; TITANIUM; VANADIUM;

EID: 48449093430     PISSN: 09368051     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00402-007-0463-z     Document Type: Article
Times cited : (8)

References (29)
  • 1
    • 0002851715 scopus 로고
    • The durability of some epoxide adhesive-bonded joints on exposure to moist warm air
    • Brewis DM, Comyn J, Tegg JL (1980) The durability of some epoxide adhesive-bonded joints on exposure to moist warm air. Int J Adhes Adhesives 1:35-39
    • (1980) Int J Adhes Adhesives , vol.1 , pp. 35-39
    • Brewis, D.M.1    Comyn, J.2    Tegg, J.L.3
  • 2
    • 50549156477 scopus 로고
    • Arthroplasty of the hip
    • Charnley J (1961) Arthroplasty of the hip. Lancet 27:1129-1132
    • (1961) Lancet , vol.27 , pp. 1129-1132
    • Charnley, J.1
  • 4
    • 0000020883 scopus 로고    scopus 로고
    • Arthroplasty of the hip
    • In: Canale ST (ed) Mosby, St. Louis
    • Harkess JW (1998) Arthroplasty of the hip. In: Canale ST (ed) Campell's operative orthopaedics. Mosby, St. Louis
    • (1998) Campell's Operative Orthopaedics
    • Harkess, J.W.1
  • 5
    • 0026438865 scopus 로고
    • Is it advantageous to strengthen the cement-metal interface and use a collar for cemented femoral components of total hip replacements?
    • Harris WH (1992) Is it advantageous to strengthen the cement-metal interface and use a collar for cemented femoral components of total hip replacements? Clin Orthop 285:67-72
    • (1992) Clin Orthop , vol.285 , pp. 67-72
    • Harris, W.H.1
  • 6
    • 0031828375 scopus 로고    scopus 로고
    • Loosening of matte versus polished cemented femoral stems
    • Howie DW, Middleton RG, Costi K (1998) Loosening of matte versus polished cemented femoral stems. J Bone Joint Surg 80B(S4):573-576
    • (1998) J Bone Joint Surg , vol.80 B , Issue.S4 , pp. 573-576
    • Howie, D.W.1    Middleton, R.G.2    Costi, K.3
  • 10
    • 0000297083 scopus 로고    scopus 로고
    • The time-dependent properties of polymethylacrylate bone cement: The interaction of shape of the femoral stems, surface finish and bone cement
    • In: Learmonth IA (ed) Springer, London
    • Lee AJC (2000) The time-dependent properties of polymethylacrylate bone cement: The interaction of shape of the femoral stems, surface finish and bone cement. In: Learmonth IA (ed) Interfaces in arthroplasty. Springer, London
    • (2000) Interfaces in Arthroplasty
    • Lee, A.J.C.1
  • 11
    • 0035662772 scopus 로고    scopus 로고
    • Evaluation of cement stresses in finite element analyses of cemented orthopaedic implants
    • Lennon AB, Prendergast PJ (2001) Evaluation of cement stresses in finite element analyses of cemented orthopaedic implants. J Biomech Eng 123:623-628
    • (2001) J Biomech Eng , vol.123 , pp. 623-628
    • Lennon, A.B.1    Prendergast, P.J.2
  • 14
    • 0003513835 scopus 로고
    • Auswahl der Werkstoffe
    • In: Kerschbaum T (ed) Urban und Schwarzenberg, München
    • Marx R (1995) Auswahl der Werkstoffe. In: Kerschbaum T (ed) Adhǎsivprothetik. Urban und Schwarzenberg, München, pp 107-120
    • (1995) Adhǎsivprothetik , pp. 107-120
    • Marx, R.1
  • 15
    • 0009500919 scopus 로고
    • Silikatisierung als Obeflächenkonditionierung von Metallen für den hydrolysebeständigen Verbund mit Kunststoffen
    • Marx R, Beldner W (1992) Silikatisierung als Obeflächenkonditionierung von Metallen für den hydrolysebeständigen Verbund mit Kunststoffen. Quintessenz 43:103-115
    • (1992) Quintessenz , vol.43 , pp. 103-115
    • Marx, R.1    Beldner, W.2
  • 17
    • 4243787255 scopus 로고
    • Mechanische eigenschaften nicht-modifizierter Knochenzemente auf PMMA-Basis
    • In: Willert HG, Buchhorn G (eds) Hans Huber Verlag, Bern
    • Müller K (1987) Mechanische eigenschaften nicht-modifizierter Knochenzemente auf PMMA-Basis. In: Willert HG, Buchhorn G (eds) Knochenzement - werkstoff, klinische erfahrungen, weiterentwicklungen. Hans Huber Verlag, Bern
    • (1987) Knochenzement - Werkstoff, Klinische Erfahrungen, Weiterentwicklungen
    • Müller, K.1
  • 18
    • 1642532353 scopus 로고    scopus 로고
    • The mechanism of loosening in cemented hip prostheses determined from long-term results
    • Müller RT, Heger I, Oldenburg M (1997) The mechanism of loosening in cemented hip prostheses determined from long-term results. Arch Orthop Traum Surg 116:41-45
    • (1997) Arch Orthop Traum Surg , vol.116 , pp. 41-45
    • Müller, R.T.1    Heger, I.2    Oldenburg, M.3
  • 20
    • 0028009338 scopus 로고
    • Alumina-on-Alumina hip replacement. Results and survivorship in patients younger than 50 years old
    • Sedel L, Nizard RS, Kerboull L, Witvoet J (1994) Alumina-on-Alumina hip replacement. Results and survivorship in patients younger than 50 years old. Clin Orthop 298:175-183
    • (1994) Clin Orthop , vol.298 , pp. 175-183
    • Sedel, L.1    Nizard, R.S.2    Kerboull, L.3    Witvoet, J.4
  • 22
    • 0024512028 scopus 로고
    • Some factors affecting the strength of the cement-metal interface
    • Stone MH, Wilkinson R, Stother IG (1989) Some factors affecting the strength of the cement-metal interface. J Bone Joint Surg 71B:217-221
    • (1989) J Bone Joint Surg , vol.71 B , pp. 217-221
    • Stone, M.H.1    Wilkinson, R.2    Stother, I.G.3
  • 23
    • 0019981269 scopus 로고
    • Ten year follow-up study of total hip replacement with particular reference to roentgenographic loosening of the components
    • Stauffer RN (1982) Ten year follow-up study of total hip replacement with particular reference to roentgenographic loosening of the components. J Bone Joint Surg 64A:983-990
    • (1982) J Bone Joint Surg , vol.64 A , pp. 983-990
    • Stauffer, R.N.1
  • 25
    • 0031052909 scopus 로고    scopus 로고
    • Cement debonding process of total hip arthroplasty stems
    • Verdonschot N, Huiskes R (1997) Cement debonding process of total hip arthroplasty stems. Clin Orthop 336:297-307
    • (1997) Clin Orthop , vol.336 , pp. 297-307
    • Verdonschot, N.1    Huiskes, R.2
  • 26
    • 0001781727 scopus 로고    scopus 로고
    • The biology of the loosening of hip implants
    • In: Jakob RP, Fulford P, Horan F (eds) EFFORT 1999, The British Editorial of Bone and Joint Surgery, London
    • Willert HG, Buchhorn HG (1999) The biology of the loosening of hip implants. In: Jakob RP, Fulford P, Horan F (eds) European instructional lectures courses, vol 4. EFFORT 1999, The British Editorial of Bone and Joint Surgery, London, pp 58-82
    • (1999) European Instructional Lectures Courses , vol.4 , pp. 58-82
    • Willert, H.G.1    Buchhorn, H.G.2
  • 27
    • 0031464956 scopus 로고    scopus 로고
    • Etiology, diagnosis and therapy of aseptic hip prosthesis loosening - A status assessment
    • Wirtz DC, Niethard FU (1997) Etiology, diagnosis and therapy of aseptic hip prosthesis loosening - a status assessment. Z Orthop 135:270-280
    • (1997) Z Orthop , vol.135 , pp. 270-280
    • Wirtz, D.C.1    Niethard, F.U.2
  • 28
    • 0034801938 scopus 로고    scopus 로고
    • Effect of femoral intramedullary irrigation on periprosthetic cement distribution: Jet lavage versus syringe lavage
    • Wirtz DC, Sellei RM, Portheine F, Prescher A, Weber M (2001) Effect of femoral intramedullary irrigation on periprosthetic cement distribution: jet lavage versus syringe lavage. Z Orthop 139(5):410-414
    • (2001) Z Orthop , vol.139 , Issue.5 , pp. 410-414
    • Wirtz, D.C.1    Sellei, R.M.2    Portheine, F.3    Prescher, A.4    Weber, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.