메뉴 건너뛰기




Volumn 5, Issue , 2007, Pages 3512-3517

Gain of KL-domain adaptive FBP image reconstruction for 4-D dynamic CT

Author keywords

[No Author keywords available]

Indexed keywords

ADAPTIVE ALGORITHMS; COMPUTERIZED TOMOGRAPHY; CUTOFF FREQUENCY; DIAGNOSTIC RADIOGRAPHY; ELECTRIC INSTRUMENT TRANSFORMERS; IMAGE PROCESSING; IMAGE RECONSTRUCTION; NOISE POLLUTION; PLANNING; REPAIR; RESTORATION; SECURITY OF DATA; SIGNAL TO NOISE RATIO; THREE DIMENSIONAL; TOMOGRAPHY;

EID: 48349131112     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2007.4436886     Document Type: Conference Paper
Times cited : (3)

References (12)
  • 3
    • 1242338927 scopus 로고    scopus 로고
    • 4D-CT imaging of a volume influenced by respiratory motion of multi-slice CT
    • T. Pan, T.Y. Lee, E. Rietzel, and G.T.Y. Chen, "4D-CT imaging of a volume influenced by respiratory motion of multi-slice CT", Medical Physics, vol. 31, pp. 333-340, 2004.
    • (2004) Medical Physics , vol.31 , pp. 333-340
    • Pan, T.1    Lee, T.Y.2    Rietzel, E.3    Chen, G.T.Y.4
  • 4
    • 0031794571 scopus 로고    scopus 로고
    • Adaptive streak artifact reduction in computed tomography resulting from excessive X-ray photon noise
    • J. Hsieh, "Adaptive streak artifact reduction in computed tomography resulting from excessive X-ray photon noise", Medical Physics, vol. 25, pp. 2139-2147, 1998.
    • (1998) Medical Physics , vol.25 , pp. 2139-2147
    • Hsieh, J.1
  • 5
    • 0035052748 scopus 로고    scopus 로고
    • Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT
    • M. Kachelrieß, O. Watzke, and W.A. Kalender, "Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT", Medical Physic's, vol. 28, pp. 475-490, 2001.
    • (2001) Medical Physic's , vol.28 , pp. 475-490
    • Kachelrieß, M.1    Watzke, O.2    Kalender, W.A.3
  • 6
    • 2942517963 scopus 로고    scopus 로고
    • Image denoising based on multiscale singularity detection for cone beam CT breast imaging
    • J. Zhong, R. Ning, and D. Conover, "Image denoising based on multiscale singularity detection for cone beam CT breast imaging", IEEE Trans. Medical Imaging, vol. 23, pp. 696-703, 2004.
    • (2004) IEEE Trans. Medical Imaging , vol.23 , pp. 696-703
    • Zhong, J.1    Ning, R.2    Conover, D.3
  • 7
    • 21144458117 scopus 로고    scopus 로고
    • Penalized-likelihood sinogram smoothing for low-dose CT
    • P.J. La Riviere, "Penalized-likelihood sinogram smoothing for low-dose CT", Medical Physics, vol. 32, pp. 1676-1683, 2005.
    • (2005) Medical Physics , vol.32 , pp. 1676-1683
    • La Riviere, P.J.1
  • 9
    • 33947260155 scopus 로고    scopus 로고
    • Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography
    • J. Wang, T. Li, H. Lu, and Z. Liang, "Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography", IEEE Trans. Medical Imaging, vol. 25, pp. 1272-1283, 2006.
    • (2006) IEEE Trans. Medical Imaging , vol.25 , pp. 1272-1283
    • Wang, J.1    Li, T.2    Lu, H.3    Liang, Z.4
  • 11
    • 34548314251 scopus 로고    scopus 로고
    • Enhanced 4D cone-beam CT with inter-phase motion model
    • T. Li, A. Koong, and L. Xing, "Enhanced 4D cone-beam CT with inter-phase motion model", Medical Physics, vol. 34, pp. 3688-3695, 2007.
    • (2007) Medical Physics , vol.34 , pp. 3688-3695
    • Li, T.1    Koong, A.2    Xing, L.3
  • 12
    • 48349115650 scopus 로고    scopus 로고
    • C-M. Kao, J.T. Yap, J. Mukherjee, and M.N. Wernick, Image reconstruction for dynamic PET based on low-order
    • C-M. Kao, J.T. Yap, J. Mukherjee, and M.N. Wernick, "Image reconstruction for dynamic PET based on low-order


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.