메뉴 건너뛰기




Volumn , Issue , 2007, Pages 1170-1175

A novel single-phase reduced parts on-line UPS with power quality conditioning capability

Author keywords

[No Author keywords available]

Indexed keywords

ACTIVE FILTERS; ELECTRIC FILTERS; ELECTRIC MEASURING INSTRUMENTS; POWER ELECTRONICS; POWER SUPPLY CIRCUITS; ULTRAVIOLET SPECTROSCOPY; UNINTERRUPTIBLE POWER SYSTEMS; WAVE FILTERS;

EID: 48349131067     PISSN: 02759306     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/PESC.2007.4342158     Document Type: Conference Paper
Times cited : (7)

References (13)
  • 1
    • 0035155041 scopus 로고    scopus 로고
    • A Three-Phase Line-Interactive UPS System Implementation with Series-Parallel Active Power-Line Conditioning Capabilities
    • S. A. Oliveira da Silva, P. Donoso-Garcia, P. C. Cortizo, P. F. Seixas, "A Three-Phase Line-Interactive UPS System Implementation with Series-Parallel Active Power-Line Conditioning Capabilities", 0-7803-7116-X/01, 2001 IEEE, pp. 2389-2396.
    • 0-7803-7116-X/01, 2001 IEEE , pp. 2389-2396
    • Oliveira da Silva, S.A.1    Donoso-Garcia, P.2    Cortizo, P.C.3    Seixas, P.F.4
  • 2
    • 84937430336 scopus 로고
    • A Novel On-Line UPS with Universal Filtering Capabilities
    • Kamran, F. and Habetler, T., "A Novel On-Line UPS with Universal Filtering Capabilities," IEEE/PESC'95, pp.500-506, 1995.
    • (1995) IEEE/PESC'95 , pp. 500-506
    • Kamran, F.1    Habetler, T.2
  • 3
    • 0030655007 scopus 로고    scopus 로고
    • A Series-Parallel Compensated Uninterruptible Power Supply with Sinusoidal Input Current and Sinusoidal Output Voltage
    • Jeon, S. -J. and Cho, G. -H., "A Series-Parallel Compensated Uninterruptible Power Supply with Sinusoidal Input Current and Sinusoidal Output Voltage," IEEE/PESC'97, pp. 297-303, 1997.
    • (1997) IEEE/PESC'97 , pp. 297-303
    • Jeon, S.-J.1    Cho, G.-H.2
  • 4
    • 0029748486 scopus 로고    scopus 로고
    • New Line-Interactive UPS System with DSP-based Active Power-Line Conditioning
    • R. Cheung, L. Cheng, P. Yu and R. Sotudeh, "New Line-Interactive UPS System with DSP-based Active Power-Line Conditioning," IEEE/PESC'96, vol. 2, pp. 981-985, 1996.
    • (1996) IEEE/PESC'96 , vol.2 , pp. 981-985
    • Cheung, R.1    Cheng, L.2    Yu, P.3    Sotudeh, R.4
  • 5
    • 85013609008 scopus 로고
    • An On-Line UPS with Improved Input-Output Characteristics
    • Joos, G., Lin Y., Ziogas, P. D. and Lindsay, J. F., "An On-Line UPS with Improved Input-Output Characteristics," IEEE/APEC'92, pp. 598-605, 1992.
    • (1992) IEEE/APEC'92 , pp. 598-605
    • Joos, G.1    Lin, Y.2    Ziogas, P.D.3    Lindsay, J.F.4
  • 6
    • 0027264334 scopus 로고
    • Performance Analysis of Parallel -Processing UPS Systems
    • Lin, Y., Joos, G. and Lindsay, J. F., "Performance Analysis of Parallel -Processing UPS Systems," APEC'93, pp. 533-539, 1993.
    • (1993) APEC'93 , pp. 533-539
    • Lin, Y.1    Joos, G.2    Lindsay, J.F.3
  • 7
    • 0030289837 scopus 로고    scopus 로고
    • New Trends in Active Filters for Power Conditioning
    • Nov./Dec, pp
    • H. Akagi, "New Trends in Active Filters for Power Conditioning", IEEE Trans. On Industry Applications, Vol. 32, No. 6, Nov./Dec., pp. 1312-1322, 1996.
    • (1996) IEEE Trans. On Industry Applications , vol.32 , Issue.6 , pp. 1312-1322
    • Akagi, H.1
  • 8
    • 0032025040 scopus 로고    scopus 로고
    • The Unified Power Quality Conditioner: The Integration of Series Active Filters and Shunt Active Filters
    • March
    • H. Fujita, H. Akagi, "The Unified Power Quality Conditioner: The Integration of Series Active Filters and Shunt Active Filters", IEEE Trans. On Power Electronics, Vol. 13, No. 2, March 1998, pp. 315-322.
    • (1998) IEEE Trans. On Power Electronics , vol.13 , Issue.2 , pp. 315-322
    • Fujita, H.1    Akagi, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.