메뉴 건너뛰기




Volumn , Issue , 2007, Pages 1404-1407

Dissolved oxygen sensing in a flow stream using molybdenum chloride optical indicators

Author keywords

[No Author keywords available]

Indexed keywords

AQUACULTURE; ARSENIC COMPOUNDS; CHLORINE COMPOUNDS; CONCENTRATION (PROCESS); DISSOLUTION; DISSOLVED OXYGEN SENSORS; FIBER OPTICS; MOLYBDENUM; NONMETALS; OFFSHORE OIL WELL PRODUCTION; OPTICAL SENSORS; OXYGEN; OXYGEN SENSORS; SENSORS; WATER QUALITY;

EID: 48349126132     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICSENS.2007.4388675     Document Type: Conference Paper
Times cited : (4)

References (17)
  • 1
    • 0032212596 scopus 로고    scopus 로고
    • In -situ mapping of community-level cellular response with catalytic microbiosensors
    • Peteu, S. F., Widman M. T. Worden R. M. "In -situ mapping of community-level cellular response with catalytic microbiosensors", Biosensors & Bioelectronics 13, 1998, pp 1197-1203.
    • (1998) Biosensors & Bioelectronics , vol.13 , pp. 1197-1203
    • Peteu, S.F.1    Widman, M.T.2    Worden, R.M.3
  • 2
    • 48349120883 scopus 로고    scopus 로고
    • [SRAC 2002] Hargreaves, J.A., Tucker, C.S., Measuring dissolve oxygen concentration in aquaculture, SRAC Publication No. 4601 2002
    • [SRAC 2002] Hargreaves, J.A., Tucker, C.S., " Measuring dissolve oxygen concentration in aquaculture", SRAC Publication No. 4601 2002
  • 4
    • 33745246901 scopus 로고    scopus 로고
    • Fiber-optic chemical sensors and biosensors
    • O. S. Wolfbeis, Fiber-optic chemical sensors and biosensors, Anal. Chem. 78, 2006, pp3859-3873.
    • (2006) Anal. Chem , vol.78 , pp. 3859-3873
    • Wolfbeis, O.S.1
  • 5
    • 48349122232 scopus 로고    scopus 로고
    • http://www.in-situ.com/In-itu/Products/Products_byApp.html
  • 6
    • 48349114726 scopus 로고    scopus 로고
    • http://www.globalw.com/products/d_opto.html
  • 7
    • 48349100990 scopus 로고    scopus 로고
    • http://www.ysihydrodata.com/news_story13.htm
  • 8
    • 48349117903 scopus 로고    scopus 로고
    • http://www.hach.com/
  • 9
    • 48349085832 scopus 로고    scopus 로고
    • http://www.oceanoptics.com/
  • 10
    • 33645225761 scopus 로고    scopus 로고
    • Stable sensors with tunable sensitivities based on class II xerogels
    • Z. Y. Tao; E. C. Tehan; Y. Tang; F. V. Bright, Stable sensors with tunable sensitivities based on class II xerogels, Anal. Chem. 78, 2006, pp1939-1945.
    • (2006) Anal. Chem , vol.78 , pp. 1939-1945
    • Tao, Z.Y.1    Tehan, E.C.2    Tang, Y.3    Bright, F.V.4
  • 11
    • 0035871734 scopus 로고    scopus 로고
    • C. McDonagh, a, C. Kolleb, A. K. McEvoya, D. L. Dowlinga, A. A. Cafollaa, S. J. Cullena and B. D. MacCraitha, Phase fluorometric dissolved oxygen sensor Sens. Actuator B-Chem. 74, 2001, pp 124-130.
    • C. McDonagh, a, C. Kolleb, A. K. McEvoya, D. L. Dowlinga, A. A. Cafollaa, S. J. Cullena and B. D. MacCraitha, "Phase fluorometric dissolved oxygen sensor" Sens. Actuator B-Chem. 74, 2001, pp 124-130.
  • 12
    • 0035871724 scopus 로고    scopus 로고
    • Novel oxygen optrode withstanding autoclavation: Technical solutions and performance
    • H. S. Voraberger; H. Kreimaier; K. Biebernik; W. Kern, "Novel oxygen optrode withstanding autoclavation: technical solutions and performance", Sens. Actuator B-Chem. 74, 2001, pp 179-185.
    • (2001) Sens. Actuator B-Chem , vol.74 , pp. 179-185
    • Voraberger, H.S.1    Kreimaier, H.2    Biebernik, K.3    Kern, W.4
  • 13
    • 33947691616 scopus 로고    scopus 로고
    • ORMOSIL oxygen sensors on polystyrene microplate for dissolved oxygen measurement
    • H.L. Pang, et al., "ORMOSIL oxygen sensors on polystyrene microplate for dissolved oxygen measurement" Sens. Actuator B-Chem. 123, 2007, pp 120-126.
    • (2007) Sens. Actuator B-Chem , vol.123 , pp. 120-126
    • Pang, H.L.1
  • 14
    • 2442694271 scopus 로고    scopus 로고
    • Long-term continuous monitoring of dissolved oxygen in cell culture medium for perfused bioreactors using optical oxygen sensors
    • F. G. Gao, A. S. Jeevarajan, and M. M. Anderson, "Long-term continuous monitoring of dissolved oxygen in cell culture medium for perfused bioreactors using optical oxygen sensors" Biotrchno Bioengineer, 86, 2004, pp 425-433.
    • (2004) Biotrchno Bioengineer , vol.86 , pp. 425-433
    • Gao, F.G.1    Jeevarajan, A.S.2    Anderson, M.M.3
  • 15
    • 0001269377 scopus 로고    scopus 로고
    • Fiber Optic Oxygen Sensor using Molybdenum Chloride Indicator Luminescence
    • Ghosh, R. N., Baker, G. L., Ruud, C. and Nocera, D. G. C. "Fiber Optic Oxygen Sensor using Molybdenum Chloride Indicator Luminescence", Appl. Physics Lett. 75, 1999, pp 2885-2887.
    • (1999) Appl. Physics Lett , vol.75 , pp. 2885-2887
    • Ghosh, R.N.1    Baker, G.L.2    Ruud, C.3    Nocera, D.G.C.4
  • 16
    • 25444530595 scopus 로고    scopus 로고
    • Mo6C112 incorporated sol-gel for oxygen sensing applications
    • Osborn, D.J., Baker G. L. and Ghosh, R. N. "Mo6C112 incorporated sol-gel for oxygen sensing applications", J. Sol-gel Sci. Tech. 36 (1), 2006, pp. 5-10.
    • (2006) J. Sol-gel Sci. Tech , vol.36 , Issue.1 , pp. 5-10
    • Osborn, D.J.1    Baker, G.L.2    Ghosh, R.N.3
  • 17
    • 48349144573 scopus 로고    scopus 로고
    • YSI550A. YSI Incorprated, 1725 Brannum Lane, Ohio USA.
    • YSI550A. YSI Incorprated, 1725 Brannum Lane, Ohio USA.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.