메뉴 건너뛰기




Volumn 1, Issue , 2007, Pages 291-298

Multi Correlated Double Sampling with exponential reset

Author keywords

[No Author keywords available]

Indexed keywords

IMAGE SENSORS; MEDICAL IMAGING; NUCLEAR FUEL REPROCESSING; OPTIMIZATION; SAMPLING; SIGNAL TO NOISE RATIO; WAVE FILTERS;

EID: 48349122629     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2007.4436333     Document Type: Conference Paper
Times cited : (6)

References (12)
  • 2
    • 51249171033 scopus 로고
    • Processing the signals from solid-state-detector in elementary particle physiscs
    • E. Gatti and P. F. Manfredi, "Processing the signals from solid-state-detector in elementary particle physiscs," Rivista del Nuovo Cimento. vol. 9, no. 1, 1986.
    • (1986) Rivista del Nuovo Cimento , vol.9 , Issue.1
    • Gatti, E.1    Manfredi, P.F.2
  • 4
    • 0025403694 scopus 로고    scopus 로고
    • Evolution in the criteria that underline the design of a monolithic preamplifier system for microstrip detectors
    • W. Buttler, G. Lutz, V. Liberali, F. Maloberti, P. F. Manfredi, V. Re, and V. Speziali, "Evolution in the criteria that underline the design of a monolithic preamplifier system for microstrip detectors," Nucl. Instr. and Meth. A, vol. 288, p. 140, 1997.
    • (1997) Nucl. Instr. and Meth. A , vol.288 , pp. 140
    • Buttler, W.1    Lutz, G.2    Liberali, V.3    Maloberti, F.4    Manfredi, P.F.5    Re, V.6    Speziali, V.7
  • 8
    • 0032023949 scopus 로고    scopus 로고
    • Impact of non-white noise in pulse amplitude measurements: A time domain approach
    • A. Pullia, "Impact of non-white noise in pulse amplitude measurements: a time domain approach." Nucl. Instr. and Meth. A, vol. 405, pp. 121-125, 1998.
    • (1998) Nucl. Instr. and Meth. A , vol.405 , pp. 121-125
    • Pullia, A.1
  • 9
    • 0001763606 scopus 로고
    • Optimum filters for detector charge measurements in presence of 1/f noise
    • E. Gatti, M. Sampietro, and P. F. Manfredi, "Optimum filters for detector charge measurements in presence of 1/f noise," Nucl. Instr. and Meth. A, vol. 287, pp. 513-520, 1990.
    • (1990) Nucl. Instr. and Meth. A , vol.287 , pp. 513-520
    • Gatti, E.1    Sampietro, M.2    Manfredi, P.F.3
  • 10
    • 0142063476 scopus 로고    scopus 로고
    • theoretical comparison between two different filtering techniques suitable for the new VLSI spectroscopic amplifier ROTOR
    • M. Porro, C. Fiorini, and L. Strueder, "theoretical comparison between two different filtering techniques suitable for the new VLSI spectroscopic amplifier ROTOR," Nucl. Instr. and Meth. A, vol. 512, pp. 179-190, 2003.
    • (2003) Nucl. Instr. and Meth. A , vol.512 , pp. 179-190
    • Porro, M.1    Fiorini, C.2    Strueder, L.3
  • 12
    • 0027555161 scopus 로고
    • The pn-CCD on-chip electronics
    • E. Pinotti, "The pn-CCD on-chip electronics." Nucl. Instr. and Meth. A. vol. 326, pp. 85-91, 1993.
    • (1993) Nucl. Instr. and Meth. A , vol.326 , pp. 85-91
    • Pinotti, E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.