메뉴 건너뛰기




Volumn 5, Issue , 2007, Pages 3206-3211

Data acquisition system design for a 1 mm3 resolution PSAPD-based PET system

Author keywords

[No Author keywords available]

Indexed keywords

APPLICATION SPECIFICS; COUNT RATE PERFORMANCES; COUNT RATES; DATA ACQUISITION ARCHITECTURES; DATA ACQUISITION SYSTEMS; DETECTOR HEADS; DETECTOR PANELS; EVALUATION SYSTEMS; EVENT BASED SIMULATIONS; GLOBAL ENERGIES; HIGH RESOLUTIONS; LOW ENERGY THRESHOLDS; LOW NOISES; MAMMOGRAPHY SYSTEMS; MONTE-CARLO SIMULATIONS; POSITION SENSITIVE AVALANCHE PHOTODIODES; RECODING; SOLID STATE DETECTORS; SPATIAL RESOLUTIONS; TIME RESOLUTIONS; TIME STAMPS; WHOLE BODIES;

EID: 48349111315     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2007.4436823     Document Type: Conference Paper
Times cited : (8)

References (5)
  • 2
    • 3342880275 scopus 로고    scopus 로고
    • Investigation of position sensitive avalanche photodiodes for a new high-resolution PET detector design
    • June Pages
    • Levin. C.S.; Foudray, A.M.K.; Olcott, P.D.; Habte. F., "Investigation of position sensitive avalanche photodiodes for a new high-resolution PET detector design", Nuclear Science, IEEE Transactions on. Vol.51, Iss.3. June 2004 Pages: 805-810
    • (2004) Nuclear Science, IEEE Transactions on , vol.51 , Issue.ISS.3 , pp. 805-810
    • Levin, C.S.1    Foudray, A.M.K.2    Olcott, P.D.3    Habte, F.4
  • 3
    • 48349108744 scopus 로고    scopus 로고
    • TO. Turner, V.B. Cajipe, M. Clajus, F. Duttweiler, S. Hayakawa, J.L. Matteson, A. Shirley, O. Yossifor. Best results of a CdZnTe pixel detector read out by RENA-2 IC,Presented at the 14th International Workshop on Room-Temperature Semiconductor X-Ray and Gamma-Ray Detectors, Rome, Italy (October 2004) and submitted to IEEE Trans. Nucl. Sci.
    • TO. Turner, V.B. Cajipe, M. Clajus, F. Duttweiler, S. Hayakawa, J.L. Matteson, A. Shirley, O. Yossifor. Best results of a CdZnTe pixel detector read out by RENA-2 IC,Presented at the 14th International Workshop on Room-Temperature Semiconductor X-Ray and Gamma-Ray Detectors, Rome, Italy (October 2004) and submitted to IEEE Trans. Nucl. Sci.
  • 4
    • 0036815754 scopus 로고    scopus 로고
    • Design of a high-resolution and high-sensitivity scintillation crystal array for PET with nearly complete light collection
    • Oct, Pages
    • Levin. C.S., "Design of a high-resolution and high-sensitivity scintillation crystal array for PET with nearly complete light collection", Nuclear Science, IEEE Transactions on, Vol.49, Iss.5. Oct 2002, Pages: 2236-2243
    • (2002) Nuclear Science, IEEE Transactions on , vol.49 , Issue.ISS.5 , pp. 2236-2243
    • Levin, C.S.1
  • 5
    • 38649100991 scopus 로고    scopus 로고
    • Olcott, P.D.; Buss, S.R.; Levin, CS.; Pratx, G.: Sramek, C.K., GRAY: High Energy Photon Ray Tracer for PET Applications. Nuclear Science Symposium Conference Record, 2006. IEEE, 4, no., pp.2011-2015, Oct. 29 2006-Nov. 1 2006
    • Olcott, P.D.; Buss, S.R.; Levin, CS.; Pratx, G.: Sramek, C.K., "GRAY: High Energy Photon Ray Tracer for PET Applications". Nuclear Science Symposium Conference Record, 2006. IEEE, vol.4, no., pp.2011-2015, Oct. 29 2006-Nov. 1 2006


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.