메뉴 건너뛰기




Volumn , Issue , 2007, Pages 23-33

Formal methods based development of a PCA infusion pump reference model: Generic infusion pump (GIP) project

Author keywords

[No Author keywords available]

Indexed keywords

CONFORMANCE CHECKING; INFUSION PUMPS; MEDICAL DEVICES; REFERENCE MODELS; REGULATORY ENVIRONMENTS; REVIEW PROCESSES; TIME CONSUMING;

EID: 48349086556     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/HCMDSS-MDPnP.2007.36     Document Type: Conference Paper
Times cited : (68)

References (21)
  • 1
    • 84897586188 scopus 로고    scopus 로고
    • Formal specifications and analysis of the computer-assisted resuscitation algorithm (CARA) infusion pump control system
    • Rajeev Alur, David Arney, Elsa L. Gunter, Insup Lee, Jaime Lee, Wonhong Nam, Frederick Pearce, Steve Van Albert, and Jiaxiang Zhou. Formal specifications and analysis of the computer-assisted resuscitation algorithm (CARA) infusion pump control system. Software Tools for Technology Transfer, 5(4):308-319, 2004.
    • (2004) Software Tools for Technology Transfer , vol.5 , Issue.4 , pp. 308-319
    • Alur, R.1    Arney, D.2    Gunter, E.L.3    Lee, I.4    Lee, J.5    Nam, W.6    Pearce, F.7    Van Albert, S.8    Zhou, J.9
  • 2
    • 0032674648 scopus 로고    scopus 로고
    • Model checking complete requirements specifications using abstraction
    • Ramesh Bharadwaj and Constance L. Heitmeyer. Model checking complete requirements specifications using abstraction. Autom. Softw. Eng., 6(1):37-68, 1999.
    • (1999) Autom. Softw. Eng , vol.6 , Issue.1 , pp. 37-68
    • Bharadwaj, R.1    Heitmeyer, C.L.2
  • 3
    • 0000289556 scopus 로고    scopus 로고
    • Formal methods: State of the art and future directions
    • Edmund M. Clarke and Jeannette M. Wing. Formal methods: state of the art and future directions. ACM Comput. Surv., 28(4):626-643, 1996.
    • (1996) ACM Comput. Surv , vol.28 , Issue.4 , pp. 626-643
    • Clarke, E.M.1    Wing, J.M.2
  • 4
    • 0032207150 scopus 로고    scopus 로고
    • Commonality and variability in software engineering
    • James Coplien, Daniel Hoffman, and David Weiss. Commonality and variability in software engineering. IEEE Software, 15(6):37-45, 1998.
    • (1998) IEEE Software , vol.15 , Issue.6 , pp. 37-45
    • Coplien, J.1    Hoffman, D.2    Weiss, D.3
  • 5
    • 0032108080 scopus 로고    scopus 로고
    • Formalizing space shuttle software requirements: Four case studies
    • Judith Crow and Ben L. Di Vito. Formalizing space shuttle software requirements: Four case studies. ACM Trans. Softw. Eng. Methodologies, 7(3):296-332, 1998.
    • (1998) ACM Trans. Softw. Eng. Methodologies , vol.7 , Issue.3 , pp. 296-332
    • Crow, J.1    Di Vito, B.L.2
  • 6
    • 84957366356 scopus 로고    scopus 로고
    • The Murø verification system
    • Rajeev Alur and Thomas A. Henzinger, editors, New Brunswick, NJ, USA, Springer Verlag
    • D. L. Dill. The Murø verification system. In Rajeev Alur and Thomas A. Henzinger, editors, Proceedings of the Eighth International Conference on Computer Aided Verification CAV, volume 1102, pages 390-393, New Brunswick, NJ, USA, 1996. Springer Verlag.
    • (1996) Proceedings of the Eighth International Conference on Computer Aided Verification CAV , vol.1102 , pp. 390-393
    • Dill, D.L.1
  • 7
    • 33646377658 scopus 로고    scopus 로고
    • Patient-controlled analgesic infusion pumps
    • ECRI
    • ECRI. Patient-controlled analgesic infusion pumps. Health Devices, 2006.
    • (2006) Health Devices
  • 8
    • 0038703389 scopus 로고    scopus 로고
    • General principles of software validation; final guidance for industry and FDA staff
    • Food and Drug Administration, Technical report, Food and Drug Administration
    • Food and Drug Administration. General principles of software validation; final guidance for industry and FDA staff. Technical report, Food and Drug Administration, 2002.
    • (2002)
  • 9
    • 33646007854 scopus 로고    scopus 로고
    • Guidance for the content of premarket submissions for software contained in medical devices - guidance for industry and FDA staff
    • Food and Drug Administration, Technical report, Food and Drug Administration
    • Food and Drug Administration. Guidance for the content of premarket submissions for software contained in medical devices - guidance for industry and FDA staff. Technical report, Food and Drug Administration, 2005.
    • (2005)
  • 10
    • 0035417837 scopus 로고    scopus 로고
    • Formal analysis of a space-craft controller using SPIN
    • Klaus Havelund, Michael R. Lowry, and John Penix. Formal analysis of a space-craft controller using SPIN. Software Engineering, 27(8), 2001.
    • (2001) Software Engineering , vol.27 , Issue.8
    • Havelund, K.1    Lowry, M.R.2    Penix, J.3
  • 11
    • 0035417837 scopus 로고    scopus 로고
    • Formal analysis of a space-craft controller using SPIN
    • Klaus Havelund, Mike Lowry, and John Penix. Formal analysis of a space-craft controller using SPIN. IEEE Trans. Softw. Eng., 27(8):749-765, 2001.
    • (2001) IEEE Trans. Softw. Eng , vol.27 , Issue.8 , pp. 749-765
    • Havelund, K.1    Lowry, M.2    Penix, J.3
  • 13
    • 48349126735 scopus 로고    scopus 로고
    • IEC 60601-2-24 medical electrical equipment- part 2-24: Particular requirements for the safety of infusion pumps and controllers
    • IEC International Electrotechnical Commission, Technical report, IEC, 1998
    • IEC International Electrotechnical Commission. IEC 60601-2-24 medical electrical equipment- part 2-24: Particular requirements for the safety of infusion pumps and controllers. Technical report, IEC, 1998.
  • 14
    • 33751343963 scopus 로고    scopus 로고
    • ANSI/AAMI/ISO 14971, medical devices - application of risk management to medical devices
    • IEC International Electrotechnical Commission, Technical report
    • IEC International Electrotechnical Commission. ANSI/AAMI/ISO 14971, medical devices - application of risk management to medical devices. Technical report, 2000.
    • (2000)
  • 16
    • 48349112281 scopus 로고    scopus 로고
    • Automatic verification of a hydroelectric power plant
    • Rosario Pugliese and Enrico Tronci. Automatic verification of a hydroelectric power plant. In FME, pages 425-444, 1996.
    • (1996) FME , pp. 425-444
    • Pugliese, R.1    Tronci, E.2
  • 19
    • 0029712749 scopus 로고    scopus 로고
    • Feasibility of model checking software requirements
    • Gaithersburg, Maryland, National Institute of Standards and Technology
    • Tirumale Sreemani and Joanne M. Atlee. Feasibility of model checking software requirements. In Compass'96: Eleventh Annual Conference on Computer Assurance, page 77, Gaithersburg, Maryland, 1996. National Institute of Standards and Technology.
    • (1996) Compass'96: Eleventh Annual Conference on Computer Assurance , pp. 77
    • Sreemani, T.1    Atlee, J.M.2
  • 20
    • 0029712749 scopus 로고    scopus 로고
    • Feasibility of model checking software requirements
    • Gaithersburg, Maryland, National Institute of Standards and Technology
    • Tirumale Sreemani and Joanne M. Atlee. Feasibility of model checking software requirements. In COMPASS'96, Proceedings of the 11th Annual Conference on Computer Assurance, pages 77-88, Gaithersburg, Maryland, 1996. National Institute of Standards and Technology.
    • (1996) COMPASS'96, Proceedings of the 11th Annual Conference on Computer Assurance , pp. 77-88
    • Sreemani, T.1    Atlee, J.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.