메뉴 건너뛰기




Volumn 22, Issue 4, 2008, Pages 282-285

Comparison between a liquid chromatography-tandem mass spectrometry assay and a fluorescent polarization immunoassay to measure whole blood everolimus concentration in heart and renal transplantations

Author keywords

Chromatography; Everolimus; Immunoassay; Therapeutic drug monitoring

Indexed keywords

EVEROLIMUS;

EID: 48249148735     PISSN: 08878013     EISSN: 10982825     Source Type: Journal    
DOI: 10.1002/jcla.20258     Document Type: Article
Times cited : (5)

References (9)
  • 1
    • 33645742164 scopus 로고    scopus 로고
    • Everolimus: A review of its use in renal and cardiac transplantation
    • Dunn C, Croom KF. Everolimus: A review of its use in renal and cardiac transplantation. Drugs 2006;66:547-570.
    • (2006) Drugs , vol.66 , pp. 547-570
    • Dunn, C.1    Croom, K.F.2
  • 2
    • 33845686426 scopus 로고    scopus 로고
    • The role of therapeutic drug monitoring in individualizing immunosuppressive drug therapy: Recent developments
    • Oellerich M, Armstrong VW. The role of therapeutic drug monitoring in individualizing immunosuppressive drug therapy: Recent developments. Ther Drug Monit 2006;28:720-725.
    • (2006) Ther Drug Monit , vol.28 , pp. 720-725
    • Oellerich, M.1    Armstrong, V.W.2
  • 3
    • 33947661868 scopus 로고    scopus 로고
    • Comparison of fluorescent polarization immunoassay (FPIA) versus HPLC to measure everolimus blood concentrations in clinical transplantation
    • Khoschsorur G, Fruehwirth F, Zelzer S, Stettin M, Halwachs-Baumann G. Comparison of fluorescent polarization immunoassay (FPIA) versus HPLC to measure everolimus blood concentrations in clinical transplantation. Clin Chim Acta 2007;380:217-221.
    • (2007) Clin Chim Acta , vol.380 , pp. 217-221
    • Khoschsorur, G.1    Fruehwirth, F.2    Zelzer, S.3    Stettin, M.4    Halwachs-Baumann, G.5
  • 4
    • 33845188715 scopus 로고    scopus 로고
    • Comparison of the Innofluor certican assay with HPLC-UV for the determination of everolimus concentrations in heart transplantation
    • Baldelli S, Crippa A, Gabrieli R, et al. Comparison of the Innofluor certican assay with HPLC-UV for the determination of everolimus concentrations in heart transplantation. Clin Biochem 2006;39:1152-1159.
    • (2006) Clin Biochem , vol.39 , pp. 1152-1159
    • Baldelli, S.1    Crippa, A.2    Gabrieli, R.3
  • 5
    • 33745855121 scopus 로고    scopus 로고
    • Evaluation of a fluorescent polarization immunoassay for whole blood everolimus determination using samples from renal transplant recipients
    • Salm P, Warnholtz C, Boyd J, Arabshahi L, Marbach P, Taylor PJ. Evaluation of a fluorescent polarization immunoassay for whole blood everolimus determination using samples from renal transplant recipients. Clin Biochem 2006;39:732-738.
    • (2006) Clin Biochem , vol.39 , pp. 732-738
    • Salm, P.1    Warnholtz, C.2    Boyd, J.3    Arabshahi, L.4    Marbach, P.5    Taylor, P.J.6
  • 6
    • 2342632546 scopus 로고    scopus 로고
    • Simultaneous determination of four immunosuppressants by means of high speed and robust on-line solid phase extraction-high performance liquid chromatography-tandem mass spectrometry
    • Koal T, Deters M, Casetta B, Kaever V. Simultaneous determination of four immunosuppressants by means of high speed and robust on-line solid phase extraction-high performance liquid chromatography-tandem mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2004;805:215-222.
    • (2004) J Chromatogr B Analyt Technol Biomed Life Sci , vol.805 , pp. 215-222
    • Koal, T.1    Deters, M.2    Casetta, B.3    Kaever, V.4
  • 7
    • 34848860896 scopus 로고    scopus 로고
    • Crossreactivity of isolated everolimus metabolites with the Innofluor Certican immunoassay for therapeutic drug monitoring of everolimus
    • Strom T, Haschke M, Boyd J, et al. Crossreactivity of isolated everolimus metabolites with the Innofluor Certican immunoassay for therapeutic drug monitoring of everolimus. Ther Drug Monit 2007;29:743-749.
    • (2007) Ther Drug Monit , vol.29 , pp. 743-749
    • Strom, T.1    Haschke, M.2    Boyd, J.3
  • 8
    • 33847134487 scopus 로고    scopus 로고
    • Internal standard selection for immunosuppressant drugs measured by high-performance liquid chromatography tandem mass spectrometry
    • Taylor PJ. Internal standard selection for immunosuppressant drugs measured by high-performance liquid chromatography tandem mass spectrometry. Ther Drug Monit 2007;29:131-132.
    • (2007) Ther Drug Monit , vol.29 , pp. 131-132
    • Taylor, P.J.1
  • 9
    • 34848887215 scopus 로고    scopus 로고
    • Internal standard selection for the high-performance liquid chromatography tandem mass spectroscopy assay of everolimus in blood
    • Hoogtanders K, van der Heijden J, Stolk LM, Neef C, Christiaans M, van Hooff J. Internal standard selection for the high-performance liquid chromatography tandem mass spectroscopy assay of everolimus in blood. Ther Drug Monit 2007;29:673-674.
    • (2007) Ther Drug Monit , vol.29 , pp. 673-674
    • Hoogtanders, K.1    van der Heijden, J.2    Stolk, L.M.3    Neef, C.4    Christiaans, M.5    van Hooff, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.