메뉴 건너뛰기




Volumn 48, Issue 8, 2008, Pages 1693-1698

Antibody identification using both automated solid-phase red cell adherence assay and a tube polyethylene glycol antiglobulin method

Author keywords

[No Author keywords available]

Indexed keywords

ALLOANTIBODY; IMMUNOGLOBULIN ANTIBODY; MACROGOL;

EID: 48249104736     PISSN: 00411132     EISSN: 15372995     Source Type: Journal    
DOI: 10.1111/j.1537-2995.2008.01736.x     Document Type: Article
Times cited : (24)

References (16)
  • 1
    • 0003809510 scopus 로고    scopus 로고
    • Chapter 12. 15th ed. Bethesda (MD): American Association of Blood Banks
    • Technical manual. Chapter 12. 15th ed. Bethesda (MD) : American Association of Blood Banks 2005.
    • (2005) Technical Manual.
  • 2
    • 0023340673 scopus 로고
    • A new potentiator of red blood cell antigen-antibody reactions
    • Nance SJ, Garratty G. A new potentiator of red blood cell antigen-antibody reactions. Am J Clin Pathol 1987 87 : 633 5.
    • (1987) Am J Clin Pathol , vol.87 , pp. 633-5
    • Nance, S.J.1    Garratty, G.2
  • 3
    • 0003750616 scopus 로고    scopus 로고
    • The identification of red cell antibodies: A comparative study of a solid phase red cell adherence system, a gel system, and agglutination testing
    • Carter JE, Gallego M, Stubbs JR. The identification of red cell antibodies: a comparative study of a solid phase red cell adherence system, a gel system, and agglutination testing. Am J Clin Pathol 1997 107 : 486 7.
    • (1997) Am J Clin Pathol , vol.107 , pp. 486-7
    • Carter, J.E.1    Gallego, M.2    Stubbs, J.R.3
  • 4
    • 0001971510 scopus 로고    scopus 로고
    • Comparison study between routine tube test (LISS), PEG tube test, gel technology and solid phase red cell adherence assays
    • Suppl
    • Reilly B, DePalma H, Cosgrove P, Parsi M, Grima K. Comparison study between routine tube test (LISS), PEG tube test, gel technology and solid phase red cell adherence assays. Transfusion 1997 37 (Suppl 64S.
    • (1997) Transfusion , vol.37
    • Reilly, B.1    Depalma, H.2    Cosgrove, P.3    Parsi, M.4    Grima, K.5
  • 5
    • 0034844874 scopus 로고    scopus 로고
    • Optimizing pretransfusion antibody detection and identification: A parallel, blinded comparison of tube PEG, solid-phase, and automated methods
    • Bunker ML, Thomas CL, Geyer SJ. Optimizing pretransfusion antibody detection and identification: a parallel, blinded comparison of tube PEG, solid-phase, and automated methods. Transfusion 2001 41 : 621 6.
    • (2001) Transfusion , vol.41 , pp. 621-6
    • Bunker, M.L.1    Thomas, C.L.2    Geyer, S.J.3
  • 6
    • 23044485924 scopus 로고    scopus 로고
    • North American pretransfusion testing practices, 2001-2004: Results from the College of American Pathologists Interlaboratory Comparison Program survey data, 2001-2004
    • Shulman IA, Maffei LM, Downes KA. North American pretransfusion testing practices, 2001-2004: results from the College of American Pathologists Interlaboratory Comparison Program survey data, 2001-2004. Arch Pathol Lab Med 2005 129 : 984 9.
    • (2005) Arch Pathol Lab Med , vol.129 , pp. 984-9
    • Shulman, I.A.1    Maffei, L.M.2    Downes, K.A.3
  • 7
    • 0002620804 scopus 로고    scopus 로고
    • Comparison of a solid phase and polyethylene glycol (PEG) IAT method in a large transfusion service
    • Suppl
    • Issitt PD, Combs MR, Bradshaw T. Comparison of a solid phase and polyethylene glycol (PEG) IAT method in a large transfusion service. Transfusion 1997 37 (Suppl 28S.
    • (1997) Transfusion , vol.37
    • Issitt, P.D.1    Combs, M.R.2    Bradshaw, T.3
  • 8
    • 26144437194 scopus 로고    scopus 로고
    • Use of a solid phase method as an adjunct procedure in antibody identification
    • Suppl
    • Combs MR, Issitt PD. Use of a solid phase method as an adjunct procedure in antibody identification. Transfusion 1997 37 (Suppl 31S.
    • (1997) Transfusion , vol.37
    • Combs, M.R.1    Issitt, P.D.2
  • 9
  • 10
    • 0032849484 scopus 로고    scopus 로고
    • Comparison of the performance of four microtube column agglutination systems in the detection of red cell alloantibodies
    • Weisbach V, Ziener A, Zimmermann R, Glaser A, Zingsem J, Eckstein R. Comparison of the performance of four microtube column agglutination systems in the detection of red cell alloantibodies. Transfusion 1999 39 : 1045 50.
    • (1999) Transfusion , vol.39 , pp. 1045-50
    • Weisbach, V.1    Ziener, A.2    Zimmermann, R.3    Glaser, A.4    Zingsem, J.5    Eckstein, R.6
  • 11
    • 33749565072 scopus 로고
    • Hemolytic transfusion reaction due to anti-Lea
    • Matson GA, Coe J, Swanson J. Hemolytic transfusion reaction due to anti-Lea. Blood 1955 10 : 1236 40.
    • (1955) Blood , vol.10 , pp. 1236-40
    • Matson, G.A.1    Coe, J.2    Swanson, J.3
  • 12
    • 48249121343 scopus 로고
    • Haemolytic transfusion reaction caused by anti-Le
    • Roy RB, Wesley RH, Fitzgerald JD. Haemolytic transfusion reaction caused by anti-Le. Vox Sang 1960 5 : 546 50.
    • (1960) Vox Sang , vol.5 , pp. 546-50
    • Roy, R.B.1    Wesley, R.H.2    Fitzgerald, J.D.3
  • 16
    • 0033392319 scopus 로고    scopus 로고
    • Delayed haemolytic transfusion reaction caused by anti-M antibody in a patient receiving interleukin-2 and interferon for metastatic renal cell cancer
    • Parry-Jones N, Gore ME, Taylor J, Treleaven JG. Delayed haemolytic transfusion reaction caused by anti-M antibody in a patient receiving interleukin-2 and interferon for metastatic renal cell cancer. Clin Lab Haematol 1999 21 : 407 8.
    • (1999) Clin Lab Haematol , vol.21 , pp. 407-8
    • Parry-Jones, N.1    Gore, M.E.2    Taylor, J.3    Treleaven, J.G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.