메뉴 건너뛰기




Volumn 6, Issue , 2007, Pages 4556-4563

MR-based renography as a replacement for radionuclide diagnostic studies

Author keywords

Dynamic contrast enhanced magnetic resonance imaging; Glomerular filtration rate; Partial volume effect; Patlak; Point spread function

Indexed keywords

GAS COOLED REACTORS; HEALTH; HISTOLOGY; MAGNETIC RESONANCE IMAGING; MEDICAL IMAGING; MIXING; OPTICAL TRANSFER FUNCTION; POROUS MATERIALS; RADIOISOTOPES; RESONANCE; VECTORS;

EID: 48149111325     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2007.4437125     Document Type: Conference Paper
Times cited : (2)

References (35)
  • 1
    • 0017291247 scopus 로고
    • Selection of routine method for determination of glomerular filtration rate in adult patients
    • Jan
    • J. Bröhner-Mortensen and P. Rödbro, "Selection of routine method for determination of glomerular filtration rate in adult patients," Scand J Clin Lib Invest, vol. 36, no. 1, pp. 35-43, Jan 1976.
    • (1976) Scand J Clin Lib Invest , vol.36 , Issue.1 , pp. 35-43
    • Bröhner-Mortensen, J.1    Rödbro, P.2
  • 2
    • 0015387619 scopus 로고
    • Estimation of glomerular filtration rate from plasma clearance of 51-chromium edetic acid
    • Aug
    • C. Chantier and T. M. Barratt, "Estimation of glomerular filtration rate from plasma clearance of 51-chromium edetic acid." Arch Dis Child, vol. 47. no. 254, pp. 613-617. Aug 1972.
    • (1972) Arch Dis Child , vol.47 , Issue.254 , pp. 613-617
    • Chantier, C.1    Barratt, T.M.2
  • 3
    • 0030853631 scopus 로고    scopus 로고
    • Long-term precision of glomerular filtration rate measurements using 51cr-edta plasma clearance
    • Aug
    • G. M. Blake, D. Roe, and C. R. Lazarus. "Long-term precision of glomerular filtration rate measurements using 51cr-edta plasma clearance." Nucl Med Commun, vol. 18, no. 8, pp. 776-784. Aug 1997.
    • (1997) Nucl Med Commun , vol.18 , Issue.8 , pp. 776-784
    • Blake, G.M.1    Roe, D.2    Lazarus, C.R.3
  • 10
    • 1542316817 scopus 로고    scopus 로고
    • Quantitation of differential renal blood flow and renal function using dynamic contrast-enhanced mri in rats
    • M. Pedersen. Y. Shi, P. Anderson, H. Stodkilde-Jorgensen, J. C. Djurhuus, I. Gordon, and J. Frokiaer, "Quantitation of differential renal blood flow and renal function using dynamic contrast-enhanced mri in rats." Magn Reson Med, vol. 51. no. 3, pp. 510-7., 2004.
    • (2004) Magn Reson Med , vol.51 , Issue.3 , pp. 510-517
    • Pedersen, M.1    Shi, Y.2    Anderson, P.3    Stodkilde-Jorgensen, H.4    Djurhuus, J.C.5    Gordon, I.6    Frokiaer, J.7
  • 11
    • 0034904810 scopus 로고    scopus 로고
    • Optimal dose of gd-dtpa in dynamic mr studies
    • H. Rusinek. V. S. Lee, and G. Johnson, "Optimal dose of gd-dtpa in dynamic mr studies." Magn Reson Med, vol. 46, no. 2, pp. 312-6., 2001.
    • (2001) Magn Reson Med , vol.46 , Issue.2 , pp. 312-316
    • Rusinek, H.1    Lee, V.S.2    Johnson, G.3
  • 12
    • 7044269262 scopus 로고    scopus 로고
    • Glomerular filtration rate: Assessment with dynamic contrast-enhanced mri and a cortical-compartment model in the rabbit kidney
    • L. Annet, L. Hermoye, F. Peeters, F. Jamar, J. P. Dehoux, and B. E. van Beers, "Glomerular filtration rate: assessment with dynamic contrast-enhanced mri and a cortical-compartment model in the rabbit kidney." J Magn Reson Imaging., vol. 20, no. 5. pp. 843-9, 2004.
    • (2004) J Magn Reson Imaging , vol.20 , Issue.5 , pp. 843-849
    • Annet, L.1    Hermoye, L.2    Peeters, F.3    Jamar, F.4    Dehoux, J.P.5    van Beers, B.E.6
  • 14
    • 0037484235 scopus 로고    scopus 로고
    • Mr to assess renal function in children
    • W. K. Rohrschneider, S. Haufe, J. H. Clorius, and J. Troger, "Mr to assess renal function in children," Eur Radiol, vol. 13, no. 5, pp. 1033-45, 2003.
    • (2003) Eur Radiol , vol.13 , Issue.5 , pp. 1033-1045
    • Rohrschneider, W.K.1    Haufe, S.2    Clorius, J.H.3    Troger, J.4
  • 16
    • 0037380346 scopus 로고    scopus 로고
    • V. S. Lee, H. Rusinek, M. E. Noz, P. Lee, M. Raghavan, and E. L. Kramer, Dynamic three-dimensional mr renography for the measurement of single kidney function: Initial experience, Radiology, 227, no. 1, pp. 289-294, 2003.
    • V. S. Lee, H. Rusinek, M. E. Noz, P." Lee, M. Raghavan, and E. L. Kramer, "Dynamic three-dimensional mr renography for the measurement of single kidney function: Initial experience," Radiology, vol. 227, no. 1, pp. 289-294, 2003.
  • 17
    • 0037255814 scopus 로고    scopus 로고
    • A unifying framework for partial volume segmentation of brain mr images
    • K. van Leemput, F. Maes, D. Vandermeulen, and P. Suetens, "A unifying framework for partial volume segmentation of brain mr images." IEEE Trans. Med. Imaging, vol. 22. no. 1, pp. 105-119, 2003.
    • (2003) IEEE Trans. Med. Imaging , vol.22 , Issue.1 , pp. 105-119
    • van Leemput, K.1    Maes, F.2    Vandermeulen, D.3    Suetens, P.4
  • 18
    • 0033233097 scopus 로고    scopus 로고
    • Mri simulation-based evaluation of image-processing and classification methods
    • R. K. S. Kwan, A. C. Evans, and G. B. Pike. "Mri simulation-based evaluation of image-processing and classification methods," Medical Imaging, IEEE Transactions on, vol. 18, no. 11. pp. 1085-1097, 1999.
    • (1999) Medical Imaging, IEEE Transactions on , vol.18 , Issue.11 , pp. 1085-1097
    • Kwan, R.K.S.1    Evans, A.C.2    Pike, G.B.3
  • 20
    • 0031955835 scopus 로고    scopus 로고
    • Correction for partial volume effects in pet: Principle and validation
    • O. G. Rousset, Y. Ma, and A. C. Evans, "Correction for partial volume effects in pet: principle and validation," J Nucl Med, vol. 39, no. 5, pp. 904-911, 1998.
    • (1998) J Nucl Med , vol.39 , Issue.5 , pp. 904-911
    • Rousset, O.G.1    Ma, Y.2    Evans, A.C.3
  • 22
    • 0020956774 scopus 로고
    • Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data
    • C. S. Patlak, R. G. Blasberg, and J. D. Fenstermacher, "Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data," J Cereb Blood Flow Metab, vol. 3. no. 1, pp. 1-7., 1983.
    • (1983) J Cereb Blood Flow Metab , vol.3 , Issue.1 , pp. 1-7
    • Patlak, C.S.1    Blasberg, R.G.2    Fenstermacher, J.D.3
  • 23
    • 0018348463 scopus 로고
    • A single injection technique for subtraction of blood background in 1311-hippuran renograms
    • M. Rutland, "A single injection technique for subtraction of blood background in 1311-hippuran renograms," Br J Radiol, vol. 52, no. 614, pp. 134-137, 1979.
    • (1979) Br J Radiol , vol.52 , Issue.614 , pp. 134-137
    • Rutland, M.1
  • 24
    • 0036187318 scopus 로고    scopus 로고
    • Evaluation of two cortical fraction estimation algorithms for the calculation of dynamic magnetic resonance renograms
    • E. L. Giele, J. A. de Priester, J. A. Blom, J. A. den Boer, J. M. van Engelshoven, and A. Hasman, "Evaluation of two cortical fraction estimation algorithms for the calculation of dynamic magnetic resonance renograms," Comput Methods Programs Biomed, vol. 67, no. 3, pp. 169-76., 2002.
    • (2002) Comput Methods Programs Biomed , vol.67 , Issue.3 , pp. 169-176
    • Giele, E.L.1    de Priester, J.A.2    Blom, J.A.3    den Boer, J.A.4    van Engelshoven, J.M.5    Hasman, A.6
  • 25
    • 0031008571 scopus 로고    scopus 로고
    • A three-dimensional volumetric test object for geometry evaluation in magnetic resonance imaging
    • D. W. McRobbie, "A three-dimensional volumetric test object for geometry evaluation in magnetic resonance imaging," Medical Physics, vol. 24, no. 5, pp. 737-742, 1997.
    • (1997) Medical Physics , vol.24 , Issue.5 , pp. 737-742
    • McRobbie, D.W.1
  • 26
    • 0017066097 scopus 로고
    • The line spread function and modulation transfer function of a computed tomography scanner
    • F. Judy, "The line spread function and modulation transfer function of a computed tomography scanner." Med. Phys., vol. 3, no. 233236, 1976.
    • (1976) Med. Phys , vol.3
    • Judy, F.1
  • 27
    • 22544434635 scopus 로고    scopus 로고
    • Comparison of edge analysis techniques for the determination of the mtf of digital radiographic systems
    • E. Samei, E. Buhr, P. Granfors, D. Vandenbroucke, and X. Wang, "Comparison of edge analysis techniques for the determination of the mtf of digital radiographic systems." Physics in Medicine and Biology, vol. 50, no, 15, pp. 3613-3625, 2005.
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.15 , pp. 3613-3625
    • Samei, E.1    Buhr, E.2    Granfors, P.3    Vandenbroucke, D.4    Wang, X.5
  • 28
    • 0028268326 scopus 로고
    • Computing the modulation transfer function of a magnetic resonance imager
    • C. Steckner, D. J. Drost, and F. S. Prato, "Computing the modulation transfer function of a magnetic resonance imager," Med. Phys., vol. 21, p. 483489, 1994.
    • (1994) Med. Phys , vol.21 , pp. 483489
    • Steckner, C.1    Drost, D.J.2    Prato, F.S.3
  • 31
    • 0032758576 scopus 로고    scopus 로고
    • S. B. Fain, S. J. Riederer, M. A. Bernstein, and J. H. III, Theoretical limits of spatial resolution in elliptical-centric contrast-enhanced 3d-mra, Magnetic Resonance in Medicine, 42, no. 6. pp. 1106-1116, 1999.
    • S. B. Fain, S. J. Riederer, M. A. Bernstein, and J. H. III, "Theoretical limits of spatial resolution in elliptical-centric contrast-enhanced 3d-mra," Magnetic Resonance in Medicine, vol. 42, no. 6. pp. 1106-1116, 1999.
  • 34
    • 0033781037 scopus 로고    scopus 로고
    • Spatial resolution in echo planar imaging: Shifting the acquisition window in k-space
    • September
    • C. Windischberger and E. Moser, "Spatial resolution in echo planar imaging: shifting the acquisition window in k-space," Magnetic Resonance Imaging, vol. 18, pp. 825-834, September 2000.
    • (2000) Magnetic Resonance Imaging , vol.18 , pp. 825-834
    • Windischberger, C.1    Moser, E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.