메뉴 건너뛰기




Volumn , Issue , 2007, Pages 2507-2510

In vitro study of frequency-dependent blood echogenicity under pulsatile flow

Author keywords

Backscattering coefficient; Cyclic echogenicity variations; High frequency ultrasound; Pulsatile flow; Red blood cell aggregation

Indexed keywords

ACOUSTIC WAVES; AGGLOMERATION; BLOOD; BOUNDARY CONDITIONS; PULSATILE FLOW; SENSITIVITY ANALYSIS; SPECTRUM ANALYZERS; SPEECH; TRANSDUCERS;

EID: 48149096870     PISSN: 10510117     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ULTSYM.2007.631     Document Type: Conference Paper
Times cited : (1)

References (14)
  • 2
    • 0027848569 scopus 로고
    • Study of red cell aggregation in pulsatile flow from ultrasonic Doppler power measurements
    • Cloutier G., Shung K. K., "Study of red cell aggregation in pulsatile flow from ultrasonic Doppler power measurements", Biorheology ,vol. 30, pp 443-461, 1993.
    • (1993) Biorheology , vol.30 , pp. 443-461
    • Cloutier, G.1    Shung, K.K.2
  • 3
    • 0029739653 scopus 로고    scopus 로고
    • Cyclic variation of Doppler power from whole blood under pulsatile flow
    • Wu S.J., Shung K.K., "Cyclic variation of Doppler power from whole blood under pulsatile flow", Ultrasound in Med. & Biol, pp 883-894, 1996.
    • (1996) Ultrasound in Med. & Biol , pp. 883-894
    • Wu, S.J.1    Shung, K.K.2
  • 4
    • 0034814324 scopus 로고    scopus 로고
    • Doppler power variation from porcine blood under steady and pulsatile flow
    • Paeng D.G., Cao P.J., Shung K.K., "Doppler power variation from porcine blood under steady and pulsatile flow", Ultrasound in Med. & Biol., vol. 27, no 9, pp 1245-1254, 2001.
    • (2001) Ultrasound in Med. & Biol , vol.27 , Issue.9 , pp. 1245-1254
    • Paeng, D.G.1    Cao, P.J.2    Shung, K.K.3
  • 5
    • 0029953395 scopus 로고    scopus 로고
    • Comparison and simulation of different levels of erythrocyte aggregation with pig, horse, sheep, calf, and normal human blood
    • Weng X., Cloutier G., Pibarot P., Durand L.-G., "Comparison and simulation of different levels of erythrocyte aggregation with pig, horse, sheep, calf, and normal human blood", Biorheology, vol. 33, no 4-5, pp 365377, 1996.
    • (1996) Biorheology , vol.33 , Issue.4-5 , pp. 365377
    • Weng, X.1    Cloutier, G.2    Pibarot, P.3    Durand, L.-G.4
  • 6
    • 34547450230 scopus 로고    scopus 로고
    • Experimental ultrasound characterization of red blood cell aggregation using the structure factor size estimator
    • Yu F, Cloutier G. Experimental ultrasound characterization of red blood cell aggregation using the structure factor size estimator. J Acoust Soc Am, vol. 122, no 1, pp 645-656, 2007
    • (2007) J Acoust Soc Am , vol.122 , Issue.1 , pp. 645-656
    • Yu, F.1    Cloutier, G.2
  • 8
    • 0031195059 scopus 로고    scopus 로고
    • An approach for measuring ultrasonic backscattering from biological tissues with focused transducer
    • Wang SH, Shung KK. An approach for measuring ultrasonic backscattering from biological tissues with focused transducer. IEEE Trans Biomed Eng, vol. 44, no 7, pp 549-554, 1997
    • (1997) IEEE Trans Biomed Eng , vol.44 , Issue.7 , pp. 549-554
    • Wang, S.H.1    Shung, K.K.2
  • 10
    • 0038033070 scopus 로고    scopus 로고
    • Modeling the frequency dependence (5120 MHz) of ultrasound backscattering by red cell aggregates in shear flow at a normal hematocrit
    • Fontaine I., Cloutier G., "Modeling the frequency dependence (5120 MHz) of ultrasound backscattering by red cell aggregates in shear flow at a normal hematocrit", J. Acoust. Soc. Am, vol. 113, no 5, pp 2893-2900, 2003.
    • (2003) J. Acoust. Soc. Am , vol.113 , Issue.5 , pp. 2893-2900
    • Fontaine, I.1    Cloutier, G.2
  • 11
    • 3142716010 scopus 로고    scopus 로고
    • NonGaussian statistics and temporal variations of the ultrasound signal backscattered by blood at frequencies between 10 and 58 MHz
    • Cloutier G., Daronat M. Savéry D., Garcia D., Durand L.-G., "NonGaussian statistics and temporal variations of the ultrasound signal backscattered by blood at frequencies between 10 and 58 MHz", J. Acoust. Soc. Am, vol. 116, no 1, pp 566-577, 2004.
    • (2004) J. Acoust. Soc. Am , vol.116 , Issue.1 , pp. 566-577
    • Cloutier, G.1    Daronat, M.2    Savéry, D.3    Garcia, D.4    Durand, L.-G.5
  • 12
    • 0031263394 scopus 로고    scopus 로고
    • Ultrasound backscattering from non-aggregating and aggregating erythrocytes - a review
    • Cloutier G., Qin Z., "Ultrasound backscattering from non-aggregating and aggregating erythrocytes - a review", Biorheology, vol. 34, no 6, pp 443-470, 1997.
    • (1997) Biorheology , vol.34 , Issue.6 , pp. 443-470
    • Cloutier, G.1    Qin, Z.2
  • 13
    • 30544453605 scopus 로고    scopus 로고
    • Detecting the process of blood coagulation and clot formation with high frequency ultrasound
    • Huang C.C., Tsui P.H., Wang S.H., Chiu C.Y., "Detecting the process of blood coagulation and clot formation with high frequency ultrasound", J. Med. Biol. Eng, vol. 25, no 4, pp 171-177, 2005.
    • (2005) J. Med. Biol. Eng , vol.25 , Issue.4 , pp. 171-177
    • Huang, C.C.1    Tsui, P.H.2    Wang, S.H.3    Chiu, C.Y.4
  • 14
    • 0001000129 scopus 로고
    • On the shear rate dependence of red cell aggregation in vitro
    • Schmid-Schönbein H, Gaehtgens P, Hirsch H. "On the shear rate dependence of red cell aggregation in vitro". J Clin Invest; vol. 47, no 6, pp 1447-1454, 1968.
    • (1968) J Clin Invest , vol.47 , Issue.6 , pp. 1447-1454
    • Schmid-Schönbein, H.1    Gaehtgens, P.2    Hirsch, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.