Volumn , Issue , 2007, Pages 676-679

Anisotropic viscoelastic properties of the corpus callosum - Application of high-resolution 3D MR-elastography to an Alzheimer mouse model

Author keywords

Alzheimer's disease; Anisotropy; Corpus callosum; Demyelination; Magnetic resonance elastography; Viscoelastic properties; White matter

Indexed keywords

ANISOTROPY; ARSENIC; BIOMECHANICS; BRAIN; CHLORINE COMPOUNDS; CRYSTALLOGRAPHY; ELASTICITY; FIBER OPTICS; HYDRODYNAMICS; THREE DIMENSIONAL; THREE DIMENSIONAL COMPUTER GRAPHICS; ULTRASONICS; VISCOSITY;

EID: 48149094552     PISSN: 10510117     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ULTSYM.2007.175     Document Type: Conference Paper
Times cited : (7)

References (9)
  • 3
    • 4243157452 scopus 로고    scopus 로고
    • Visualization of beta-amyloid plaques in a transgenic mouse model of Alzheimer's disease using MR microscopy without contrast reagents
    • Lee SP, Falangola MA, Nixon RA, Duff K, Helpem JA. Visualization of beta-amyloid plaques in a transgenic mouse model of Alzheimer's disease using MR microscopy without contrast reagents. Magn Reson Med 2004;52(3):538-544.
    • (2004) Magn Reson Med , vol.52 , Issue.3 , pp. 538-544
    • Lee, S.P.1    Falangola, M.A.2    Nixon, R.A.3    Duff, K.4    Helpem, J.A.5
  • 6
    • 14744298662 scopus 로고    scopus 로고
    • Noninvasive in vivo MRI detection of neuritic plaques associated with iron in APP[V717I] transgenic mice, a model for Alzheimer's disease
    • Vanhoutte G, Dewachter I, Borghgraef P, Van Leuven F, Van der Linden A. Noninvasive in vivo MRI detection of neuritic plaques associated with iron in APP[V717I] transgenic mice, a model for Alzheimer's disease. Magn Reson Med 2005;53(3):607-613.
    • (2005) Magn Reson Med , vol.53 , Issue.3 , pp. 607-613
    • Vanhoutte, G.1    Dewachter, I.2    Borghgraef, P.3    Van Leuven, F.4    Van der Linden, A.5
  • 7
    • 0043093794 scopus 로고    scopus 로고
    • Assessment of axonal degeneration on Alzheimer's disease with diffusion tensor MRI
    • Jul;
    • Stahl R, Dietrich O, Teipel S, Hampel H, Reiser MF, Schoenberg SO. Assessment of axonal degeneration on Alzheimer's disease with diffusion tensor MRI. Radiologe. 2003 Jul;43(7):566-75.
    • (2003) Radiologe , vol.43 , Issue.7 , pp. 566-575
    • Stahl, R.1    Dietrich, O.2    Teipel, S.3    Hampel, H.4    Reiser, M.F.5    Schoenberg, S.O.6
  • 9
    • 14744286408 scopus 로고    scopus 로고
    • Mechanical transient-based magnetic resonance elastography
    • McCracken PJ, Manduca A, Felmlee J, Ehman RL. Mechanical transient-based magnetic resonance elastography. Magn Reson Med 2005;53(3):628-639.
    • (2005) Magn Reson Med , vol.53 , Issue.3 , pp. 628-639
    • McCracken, P.J.1    Manduca, A.2    Felmlee, J.3    Ehman, R.L.4