메뉴 건너뛰기




Volumn 6, Issue , 2007, Pages 4615-4619

Optimization of design parameters of a prototype CCD-based lens-coupled imaging system for the detection of beta particles in a microfluidic chip

Author keywords

[No Author keywords available]

Indexed keywords

BIOCHIPS; CHARGE COUPLED DEVICES; DIGITAL CAMERAS; DIGITAL IMAGE STORAGE; FLUIDIC DEVICES; IMAGING SYSTEMS; INTEGRATED CIRCUITS; LARGE SCALE SYSTEMS; LENSES; LIGHT EMISSION; LUMINESCENCE; MEDICAL IMAGING; NANOFLUIDICS; OPTICAL INSTRUMENTS; OPTIMIZATION; OPTOELECTRONIC DEVICES; SCINTILLATION; SCINTILLATION COUNTERS; SIGNAL PROCESSING; SIGNAL TO NOISE RATIO; SULFATE MINERALS;

EID: 48149089158     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2007.4437137     Document Type: Conference Paper
Times cited : (8)

References (10)
  • 1
    • 38649093982 scopus 로고    scopus 로고
    • Detection of Beta Particles in a Microfluidic Chip using a Scintillator and CCD
    • Jennifer S. Cho, et al.. "Detection of Beta Particles in a Microfluidic Chip using a Scintillator and CCD", IEEE NSS-MIC conference record, M06-191, 2006
    • (2006) IEEE NSS-MIC conference record , vol.M06-191
    • Cho, J.S.1
  • 2
    • 0347134477 scopus 로고    scopus 로고
    • Microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies
    • Samuel K. Sia, et al., "Microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies", Electrophoresis, vol. 24, 3563-3576, 2003
    • (2003) Electrophoresis , vol.24 , pp. 3563-3576
    • Sia, S.K.1
  • 3
    • 29144528086 scopus 로고    scopus 로고
    • Multistep Synthesis of a Radiolabeled Imaging Probe Using Integrated Microfluidics
    • Dec
    • Chung-Cheng Lee, et al., "Multistep Synthesis of a Radiolabeled Imaging Probe Using Integrated Microfluidics", Science, vol. 310, no. 16, 1793-1796, Dec. 2005
    • (2005) Science , vol.310 , Issue.16 , pp. 1793-1796
    • Lee, C.-C.1
  • 6
    • 17644394588 scopus 로고    scopus 로고
    • Printed Sources for Positron Emission Tomography (PET)
    • February
    • Vesna Sossi, et al., "Printed Sources for Positron Emission Tomography (PET)", IEEE Transactions on Nuclear Science, vol. 52, February, 2005
    • (2005) IEEE Transactions on Nuclear Science , vol.52
    • Sossi, V.1
  • 7
    • 23544462582 scopus 로고
    • Limits for Qualitative Detection and Quantitative Determination
    • Mar
    • Lloyd A. Currie, "Limits for Qualitative Detection and Quantitative Determination", Analytical Chem., vol. 40, pp. 586-593, Mar. 1968.
    • (1968) Analytical Chem , vol.40 , pp. 586-593
    • Currie, L.A.1
  • 8
    • 0033059817 scopus 로고    scopus 로고
    • Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution
    • Craig S. Levin, et al., "Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution", Phys. Med. Biol., vol 44 (1999) 781-799
    • (1999) Phys. Med. Biol , vol.44 , pp. 781-799
    • Levin, C.S.1
  • 9
    • 0028070545 scopus 로고
    • Methods to calculate the lens efficiency in optically coupled CCD x-ray imaging systems
    • July
    • Hong Liu, et al., "Methods to calculate the lens efficiency in optically coupled CCD x-ray imaging systems", Medical Physics, vol. 21 (7), July 1994
    • (1994) Medical Physics , vol.21 , Issue.7
    • Liu, H.1
  • 10
    • 0030894680 scopus 로고    scopus 로고
    • Lens coupling efficiency: Derivation and application under differing geometrical assumptions
    • April
    • Tong Yu, John M. Boone, "Lens coupling efficiency: Derivation and application under differing geometrical assumptions", Medical Physics, vol. 24 (4), April, 1997
    • (1997) Medical Physics , vol.24 , Issue.4
    • Yu, T.1    Boone, J.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.