메뉴 건너뛰기




Volumn 6, Issue , 2007, Pages 4279-4284

High-sensitivity SPECT imaging using large collimator holes and geometric blurring compensation

Author keywords

Collimator; High sensitivity; Resolution compensation; SPECT

Indexed keywords

COMPUTATIONAL GEOMETRY; COMPUTATIONAL METHODS; COMPUTER SIMULATION; IMAGE QUALITY; IMAGE RESOLUTION; LAWS AND LEGISLATION; MEDICAL IMAGING; OPTICAL INSTRUMENTS; SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY;

EID: 48149088791     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2007.4437062     Document Type: Conference Paper
Times cited : (4)

References (9)
  • 2
    • 0036816186 scopus 로고    scopus 로고
    • A channelized-hotelling-trace collimator design method based on reconstruction rather than projection
    • G. L. Zeng and G. T. Gullberg, "A channelized-hotelling-trace collimator design method based on reconstruction rather than projection," IEEE. Trans. Nucl. Sci., vol. 49, no. 5. pp. 2155-2158, 2002.
    • (2002) IEEE. Trans. Nucl. Sci , vol.49 , Issue.5 , pp. 2155-2158
    • Zeng, G.L.1    Gullberg, G.T.2
  • 3
    • 0002198327 scopus 로고    scopus 로고
    • Collimator characteristics and design
    • R. E. Henkin et al, Eds. St. Louis, MO: Mosby, pp
    • D. L. Gunter et al., "Collimator characteristics and design," in Nuclear Medicine. R. E. Henkin et al., Eds. St. Louis, MO: Mosby, pp. 96-124, 1996.
    • (1996) Nuclear Medicine , pp. 96-124
    • Gunter, D.L.1
  • 4
    • 0026928798 scopus 로고
    • Frequency domain implementation of the three-dimensional geometric point response correction in SPECT imaging
    • G. L. Zeng and G. T. Gullberg, "Frequency domain implementation of the three-dimensional geometric point response correction in SPECT imaging," IEEE Trans. Nucl. Sci., vol. 39, no. 5, pp. 1444-1453, 1992.
    • (1992) IEEE Trans. Nucl. Sci , vol.39 , Issue.5 , pp. 1444-1453
    • Zeng, G.L.1    Gullberg, G.T.2
  • 5
    • 0032137663 scopus 로고    scopus 로고
    • A slab-to-slab blurring model for geometric point response correction and attenuation correction using iterative reconstruction algorithm
    • C. Bai, G. L. Zeng, G. T. Gullberg, F. DiFilippo, and S. Miller, "A slab-to-slab blurring model for geometric point response correction and attenuation correction using iterative reconstruction algorithm," IEEE Trans. Nucl. Sci., vol. 45, pp. 2168-2173, 1998.
    • (1998) IEEE Trans. Nucl. Sci , vol.45 , pp. 2168-2173
    • Bai, C.1    Zeng, G.L.2    Gullberg, G.T.3    DiFilippo, F.4    Miller, S.5
  • 6
    • 0025416078 scopus 로고
    • A projector, backprojector pair which accounts for the two-dimenstional depth and distance dependent blurring in SPECT
    • B. C. Penney, M. A. King, and K. Knesaurek, "A projector, backprojector pair which accounts for the two-dimenstional depth and distance dependent blurring in SPECT," IEEE Trans. Nucl. Sci., vol. 37, pp. 681-686, 1991.
    • (1991) IEEE Trans. Nucl. Sci , vol.37 , pp. 681-686
    • Penney, B.C.1    King, M.A.2    Knesaurek, K.3
  • 8
    • 0026139673 scopus 로고
    • Three-dimensional iterative reconstruction algorithms with attenuation and geometric point response correction
    • G. L. Zeng and G. T. Gullberg, "Three-dimensional iterative reconstruction algorithms with attenuation and geometric point response correction," IEEE. Trans. Nucl. Sci., vol. 38. no. 2, pp. 693-702, 1991.
    • (1991) IEEE. Trans. Nucl. Sci , vol.38 , Issue.2 , pp. 693-702
    • Zeng, G.L.1    Gullberg, G.T.2
  • 9
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • L. A. Shepp and Y. Vardi, "Maximum likelihood reconstruction for emission tomography," IEEE Trans. Med. Imag., vol. 1, pp. 113-122, 1982.
    • (1982) IEEE Trans. Med. Imag , vol.1 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.