메뉴 건너뛰기




Volumn , Issue , 2007, Pages 177-180

Accurate removal of baseline wander in ECG using empirical mode decomposition

Author keywords

[No Author keywords available]

Indexed keywords

BASELINE WANDER; BIOMEDICAL IMAGING; ELECTROCARDIOGRAM (ECG); EMD METHOD; EMPIRICAL MODE DECOMPOSITION; INTERNATIONAL CONFERENCES; INTERNATIONAL SYMPOSIUM; PRE-PROCESSING; SOURCE IMAGING;

EID: 48049124586     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NFSI-ICFBI.2007.4387719     Document Type: Conference Paper
Times cited : (50)

References (12)
  • 2
    • 0022270421 scopus 로고
    • Removal of Base-Line Wander and Power-Line Interference from the ECG by an Efficient FIR Filter with a Reduced Number of Taps
    • Dec
    • J. A. Van Alste, T. S. Schilder, "Removal of Base-Line Wander and Power-Line Interference from the ECG by an Efficient FIR Filter with a Reduced Number of Taps," IEEE Trans. Biomed., Eng., vol. 34, pp. 1052-1060, Dec. 1985.
    • (1985) IEEE Trans. Biomed., Eng , vol.34 , pp. 1052-1060
    • Van Alste, J.A.1    Schilder, T.S.2
  • 3
    • 0026624454 scopus 로고
    • Time-varying filtering for removal of baseline wander in exercise ECGs
    • Sep
    • L. Sornmo, "Time-varying filtering for removal of baseline wander in exercise ECGs," in Proc. Conf. Computers in Cardiology, Sep. 1991, pp. 145-148.
    • (1991) Proc. Conf. Computers in Cardiology , pp. 145-148
    • Sornmo, L.1
  • 4
    • 0030032972 scopus 로고    scopus 로고
    • P. S. Hamilton, A comparison of adaptive and nonadaptive filters for reduction of power line interference in the ECG, IEEE Trans. Biomed., Eng., vol43, pp. 105-109, Jan. 1996.
    • P. S. Hamilton, "A comparison of adaptive and nonadaptive filters for reduction of power line interference in the ECG," IEEE Trans. Biomed., Eng., vol43, pp. 105-109, Jan. 1996.
  • 5
    • 85057648918 scopus 로고
    • Adaptive baseline wander removal in the ECG: Comparative analysis with cubic spline technique
    • USA
    • R. Jane, P. Laguna, et al, "Adaptive baseline wander removal in the ECG: Comparative analysis with cubic spline technique," in proc. Conf. Computers in Cardiology, USA, 1992, pp. 143-146.
    • (1992) proc. Conf. Computers in Cardiology , pp. 143-146
    • Jane, R.1    Laguna, P.2
  • 9
    • 27244455211 scopus 로고    scopus 로고
    • A Method for the Automated Detection of Venous Gas Bubbles in Humans Using Empirical Mode Decomposition
    • Oct
    • M. A. Chappell, S. J. Payne, "A Method for the Automated Detection of Venous Gas Bubbles in Humans Using Empirical Mode Decomposition," Jou. Annals of Biomedical Engineering, vol. 33, Oct. 2005, pp. 1411-1421.
    • (2005) Jou. Annals of Biomedical Engineering , vol.33 , pp. 1411-1421
    • Chappell, M.A.1    Payne, S.J.2
  • 12
    • 33947208525 scopus 로고    scopus 로고
    • A New Method for Removal of Baseline Wander and Power Line Interference in ECG Signals
    • China, Aug 13-16
    • Z. D. Zhao, Y. Q. Chen, "A New Method for Removal of Baseline Wander and Power Line Interference in ECG Signals," in Proc. 15th Conf. Machine Learning and Cybernetics, China, Aug 13-16, 2006, pp. 4342-4347.
    • (2006) Proc. 15th Conf. Machine Learning and Cybernetics , pp. 4342-4347
    • Zhao, Z.D.1    Chen, Y.Q.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.