메뉴 건너뛰기




Volumn 161, Issue , 2008, Pages 162-167

Membrane characteristics

Author keywords

[No Author keywords available]

Indexed keywords

ARTIFICIAL MEMBRANE; HUMAN; INSTRUMENTATION; RENAL REPLACEMENT THERAPY; REVIEW;

EID: 48049095768     PISSN: 03025144     EISSN: None     Source Type: Book Series    
DOI: 10.1159/000130673     Document Type: Conference Paper
Times cited : (3)

References (10)
  • 1
    • 0002663303 scopus 로고
    • Hemodialysis: Physical principles and technical considerations
    • Brenner BM, Rector FC eds, ed 2. Philadelphia, Saunders
    • Colton CK, Lowrie EG: Hemodialysis: physical principles and technical considerations; in Brenner BM, Rector FC (eds): The Kidney, ed 2. Philadelphia, Saunders, 1981, pp 2425-2489.
    • (1981) The Kidney , pp. 2425-2489
    • Colton, C.K.1    Lowrie, E.G.2
  • 3
    • 0035235707 scopus 로고    scopus 로고
    • Quantitative characterization of hemodialyzer solute and water transport
    • Clark WR: Quantitative characterization of hemodialyzer solute and water transport. Semin Dial 2001;14:32-36.
    • (2001) Semin Dial , vol.14 , pp. 32-36
    • Clark, W.R.1
  • 4
    • 0033852947 scopus 로고    scopus 로고
    • Chronic inflammation in hemodialysis: The role of contaminated dialysate
    • Lonnemann G: Chronic inflammation in hemodialysis: the role of contaminated dialysate. Blood Purif 2000;18:214-223.
    • (2000) Blood Purif , vol.18 , pp. 214-223
    • Lonnemann, G.1
  • 5
    • 0033456219 scopus 로고    scopus 로고
    • Effect of membrane composition and structure on performance and biocompatibility in hemodialysis
    • Clark WR, Hamburger RJ, Lysaght MJ: Effect of membrane composition and structure on performance and biocompatibility in hemodialysis. Kidney Int 1999;56:2005-2015.
    • (1999) Kidney Int , vol.56 , pp. 2005-2015
    • Clark, W.R.1    Hamburger, R.J.2    Lysaght, M.J.3
  • 6
    • 0036559284 scopus 로고    scopus 로고
    • Properties of membranes used for hemodialysis therapy
    • Clark WR, Gao D: Properties of membranes used for hemodialysis therapy. Semin Dial 2002;15:191-195.
    • (2002) Semin Dial , vol.15 , pp. 191-195
    • Clark, W.R.1    Gao, D.2
  • 7
    • 0035742643 scopus 로고    scopus 로고
    • Biocompatibility of hemodialysis membranes: Interrelations between plasma complement and cytokine levels
    • Varela MP, Kimmel PL, Phillips TM, Mishkin GJ, Lew SQ, Bosch JP: Biocompatibility of hemodialysis membranes: interrelations between plasma complement and cytokine levels. Blood Purif 2001;19:370-379.
    • (2001) Blood Purif , vol.19 , pp. 370-379
    • Varela, M.P.1    Kimmel, P.L.2    Phillips, T.M.3    Mishkin, G.J.4    Lew, S.Q.5    Bosch, J.P.6
  • 8
    • 28844476364 scopus 로고    scopus 로고
    • What clinically important advances in understanding and improving dialyzer function have occurred recently?
    • Mishkin GJ: What clinically important advances in understanding and improving dialyzer function have occurred recently? Semin Dial 2001;14:170-173.
    • (2001) Semin Dial , vol.14 , pp. 170-173
    • Mishkin, G.J.1
  • 9
    • 0032608527 scopus 로고    scopus 로고
    • Polymethylmethacrylate: One biomaterial for a series of membrane
    • Basel, Karger
    • Takeyama T, Sakai Y: Polymethylmethacrylate: one biomaterial for a series of membrane. Contrib Nephrol. Basel, Karger, 1999, vol 125, pp 9-24.
    • (1999) Contrib Nephrol , vol.125 , pp. 9-24
    • Takeyama, T.1    Sakai, Y.2
  • 10
    • 28444451861 scopus 로고    scopus 로고
    • Protein-leaking membranes for hemodialysis: A new class of membranes in search of an application?
    • Ward RA: Protein-leaking membranes for hemodialysis: a new class of membranes in search of an application? J Am Soc Nephrol 2005;16:2421-2430.
    • (2005) J Am Soc Nephrol , vol.16 , pp. 2421-2430
    • Ward, R.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.