메뉴 건너뛰기




Volumn 86, Issue 2, 2008, Pages 417-421

A biomechanical and histological analysis of standard versus hydroxyapatite-coated pins for external fixation

Author keywords

Bone; External fixation; Hydroxyapatite; Interface; Pin; Torque

Indexed keywords

COMPARATIVE EVALUATIONS; EXTERNAL FIXATION; HISTOLOGICAL ANALYSIS; HYDROXYAPATITE (HA) COATINGS; INSERTION TORQUE;

EID: 47949123687     PISSN: 15524973     EISSN: 15524981     Source Type: Journal    
DOI: 10.1002/jbm.b.31036     Document Type: Article
Times cited : (32)

References (23)
  • 1
    • 4444244714 scopus 로고    scopus 로고
    • Hydroxyapatite-coated external-fixation pins: The effect on pin loosening and pin-track infection in leg lengthening for short stature
    • Pizà G, Caja VL, Gonzàlel-Viejo MA, Navarro A. Hydroxyapatite-coated external-fixation pins: The effect on pin loosening and pin-track infection in leg lengthening for short stature. J Bone Joint Surg 2004;86B:892-897.
    • (2004) J Bone Joint Surg , vol.86 B , pp. 892-897
    • Pizà, G.1    Caja, V.L.2    Gonzàlel-Viejo, M.A.3    Navarro, A.4
  • 2
    • 0032897234 scopus 로고    scopus 로고
    • Pin-tract complications in external fixation of fractures of distal radius
    • Ahlborg HG, Josefsson PO. Pin-tract complications in external fixation of fractures of distal radius. Acta Orthop Scand 1999;70:116-118.
    • (1999) Acta Orthop Scand , vol.70 , pp. 116-118
    • Ahlborg, H.G.1    Josefsson, P.O.2
  • 3
    • 0029872028 scopus 로고    scopus 로고
    • Hydroxyapatite-coated external fixation pins
    • Caja VL, Moroni A. Hydroxyapatite-coated external fixation pins. Clin Orthop 1996;325:269-275.
    • (1996) Clin Orthop , vol.325 , pp. 269-275
    • Caja, V.L.1    Moroni, A.2
  • 4
    • 0042635522 scopus 로고    scopus 로고
    • Hydroxyapatite coating of external fixation pins to decrease axial deformity during tibial lengthening for short stature
    • Caja VL, Pizà G, Navarro A. Hydroxyapatite coating of external fixation pins to decrease axial deformity during tibial lengthening for short stature. J Bone Joint Surg 2003;85A:1527-1531.
    • (2003) J Bone Joint Surg , vol.85 A , pp. 1527-1531
    • Caja, V.L.1    Pizà, G.2    Navarro, A.3
  • 5
    • 0031111952 scopus 로고    scopus 로고
    • Biomechanical scanning electron microscopy and microhardness analyses of the bone/pin interface in hydroxyapatite-coated versus uncoated pins
    • Moroni A, Caja VL, Maltarello MC, Savarino L, Marinelli F, Stea S, Visentin M, Giannini S. Biomechanical scanning electron microscopy and microhardness analyses of the bone/pin interface in hydroxyapatite-coated versus uncoated pins. J Orthop Trauma 1997;11:154-161.
    • (1997) J Orthop Trauma , vol.11 , pp. 154-161
    • Moroni, A.1    Caja, V.L.2    Maltarello, M.C.3    Savarino, L.4    Marinelli, F.5    Stea, S.6    Visentin, M.7    Giannini, S.8
  • 6
    • 0000578133 scopus 로고    scopus 로고
    • Improvement of the bone-pin interface strength in osteoporotic bone with the use of hydroxyapatite-coated tapered external-fixation pins
    • Moroni A, Faldini C, Marchetti S, Manca M, Consoli V, Giannini S. Improvement of the bone-pin interface strength in osteoporotic bone with the use of hydroxyapatite-coated tapered external-fixation pins. J Bone Joint Surg 2001;83A:717-721.
    • (2001) J Bone Joint Surg , vol.83 A , pp. 717-721
    • Moroni, A.1    Faldini, C.2    Marchetti, S.3    Manca, M.4    Consoli, V.5    Giannini, S.6
  • 7
    • 0035405841 scopus 로고    scopus 로고
    • Fixation strength and pin tract infection of hydroxyapatite-coated tapered pins
    • Moroni A, Heikkila J, Magyar G, Toksvig-Larsen S, Giannini S. Fixation strength and pin tract infection of hydroxyapatite-coated tapered pins. Clin Orthop 2001;388:209-217.
    • (2001) Clin Orthop , vol.388 , pp. 209-217
    • Moroni, A.1    Heikkila, J.2    Magyar, G.3    Toksvig-Larsen, S.4    Giannini, S.5
  • 8
    • 0029693165 scopus 로고    scopus 로고
    • Improvement of the pin-bone interface with hydroxyapatite coating. An in vivo long-term experimental study
    • Moroni A, Orienti L, Stea S, Visentin M. Improvement of the pin-bone interface with hydroxyapatite coating. An in vivo long-term experimental study. J Orthop Trauma 1996;10:236-242.
    • (1996) J Orthop Trauma , vol.10 , pp. 236-242
    • Moroni, A.1    Orienti, L.2    Stea, S.3    Visentin, M.4
  • 9
    • 0026303782 scopus 로고
    • Induction and prevention of pin loosening in external fixation: An in vivo study on sheep tibiae
    • Hyldahl S, Pearson S, Tepic S, Perren SM. Induction and prevention of pin loosening in external fixation: An in vivo study on sheep tibiae. J Orthop Trauma 1991;5:485-492.
    • (1991) J Orthop Trauma , vol.5 , pp. 485-492
    • Hyldahl, S.1    Pearson, S.2    Tepic, S.3    Perren, S.M.4
  • 10
    • 0030968773 scopus 로고    scopus 로고
    • Hydroxyapatite coating threaded pins enhances fixation
    • Magyar G, Toksvig-Larsen S, Moroni A. Hydroxyapatite coating threaded pins enhances fixation. J Bone Joint Surg 1997;79B:487-489.
    • (1997) J Bone Joint Surg , vol.79 B , pp. 487-489
    • Magyar, G.1    Toksvig-Larsen, S.2    Moroni, A.3
  • 11
    • 0036634415 scopus 로고    scopus 로고
    • Hydroxyapatite-coated schanz pins in external fixators used for distraction osteogenesis
    • Pommer A, Muhr G, David A. Hydroxyapatite-coated schanz pins in external fixators used for distraction osteogenesis. J Bone Joint Surg 2002;84A:1162-1166.
    • (2002) J Bone Joint Surg , vol.84 A , pp. 1162-1166
    • Pommer, A.1    Muhr, G.2    David, A.3
  • 13
    • 0035689180 scopus 로고    scopus 로고
    • Fine threads versus coarse threads. A comparison of the maximum holding power
    • Gausepohl T, Mohring R, Penning D, Koebke J. Fine threads versus coarse threads. A comparison of the maximum holding power. Injury 2001;32(Suppl 4):1-7.
    • (2001) Injury , vol.32 , Issue.SUPPL. 4 , pp. 1-7
    • Gausepohl, T.1    Mohring, R.2    Penning, D.3    Koebke, J.4
  • 14
    • 0034251992 scopus 로고    scopus 로고
    • Evaluation of a new method of small fragment fracture fixation in a medial malleolus fracture model
    • Rovinsky D, Haskell A, Liu Q, Paiement GD, Bradforf DS. Evaluation of a new method of small fragment fracture fixation in a medial malleolus fracture model. J Orthop Trauma 2000;14:420-425.
    • (2000) J Orthop Trauma , vol.14 , pp. 420-425
    • Rovinsky, D.1    Haskell, A.2    Liu, Q.3    Paiement, G.D.4    Bradforf, D.S.5
  • 15
    • 0001887153 scopus 로고
    • Biomechanics of fracture repair and fixation
    • Mow VC, Hayes WC, editors, New York: Raven;
    • Chao EYS, Aro HT. Biomechanics of fracture repair and fixation. In: Mow VC, Hayes WC, editors. Basic Orthopaedic Biomechanics. New York: Raven; 1991. pp 293-336.
    • (1991) Basic Orthopaedic Biomechanics , pp. 293-336
    • Chao, E.Y.S.1    Aro, H.T.2
  • 16
    • 0023679936 scopus 로고    scopus 로고
    • Mechanical performance of the standard Orthofix external fixator
    • Chao EYS, Hein TJ. Mechanical performance of the standard Orthofix external fixator. Orthopaedics 1998;11:1057-1069.
    • (1998) Orthopaedics , vol.11 , pp. 1057-1069
    • Chao, E.Y.S.1    Hein, T.J.2
  • 17
    • 0027435284 scopus 로고
    • Cortical bone reactions at the interface of the external fixation half-pins under different looking conditions
    • Aro HT, Markel MD, Chao EYS. Cortical bone reactions at the interface of the external fixation half-pins under different looking conditions. J Trauma 1993;35:776-785.
    • (1993) J Trauma , vol.35 , pp. 776-785
    • Aro, H.T.1    Markel, M.D.2    Chao, E.Y.S.3
  • 19
    • 0038374248 scopus 로고    scopus 로고
    • Davidson SR, James DF. Drilling in bone: Modeling heat generation and temperature distribution. J Biomech Eng 2003;125:305-314.
    • Davidson SR, James DF. Drilling in bone: Modeling heat generation and temperature distribution. J Biomech Eng 2003;125:305-314.
  • 22
    • 0036194358 scopus 로고    scopus 로고
    • Techniques to avoid pin loosening and infections in external fixation
    • Moroni A, Vannini F, Mosca M, Giannini S. Techniques to avoid pin loosening and infections in external fixation. J Orthop Trauma 2002;16:189-195.
    • (2002) J Orthop Trauma , vol.16 , pp. 189-195
    • Moroni, A.1    Vannini, F.2    Mosca, M.3    Giannini, S.4
  • 23
    • 0029135259 scopus 로고
    • Thermal response and torque resistance of five cortical half-pins under simulated insertion technique
    • Wikenheiser MA, Markel MD, Lewallen DG, Chao EY. Thermal response and torque resistance of five cortical half-pins under simulated insertion technique. J Orthop Res 1995;13:615-619.
    • (1995) J Orthop Res , vol.13 , pp. 615-619
    • Wikenheiser, M.A.1    Markel, M.D.2    Lewallen, D.G.3    Chao, E.Y.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.