메뉴 건너뛰기




Volumn 20, Issue 3, 2008, Pages 223-240

Factors affecting the dissolution of copper in transformer oils

Author keywords

Copper; Corrosion; Dissolution; Oil oxidation; Transformer oil

Indexed keywords

ACIDS; ARSENIC COMPOUNDS; CHEMICAL ENGINEERING; CHEMICAL REACTIONS; COPPER; COPPER CORROSION; INSULATING OIL; METAL REFINING; NITROGEN; NONMETALS; OLEFINS; OXIDATION; PEROXIDES; PETROLEUM REFINING;

EID: 47749130061     PISSN: 09540075     EISSN: None     Source Type: Journal    
DOI: 10.1002/ls.63     Document Type: Article
Times cited : (46)

References (26)
  • 2
    • 33745997392 scopus 로고    scopus 로고
    • Study of fuel insolubles: Formation conditions and characterization of copper compounds
    • and references therein
    • Doyle A, Tristäo MLB, Felcman J. Study of fuel insolubles: Formation conditions and characterization of copper compounds. Fuel 2006; 85(14-15):2195-2201, and references therein.
    • (2006) Fuel , vol.85 , Issue.14-15 , pp. 2195-2201
    • Doyle, A.1    Tristäo, M.L.B.2    Felcman, J.3
  • 8
    • 74549208717 scopus 로고    scopus 로고
    • US Environmental Protection Agency, Office of Environmental Information, EPA 260-R-01-002; Washington DC, July, Chapter 9, p
    • US Environmental Protection Agency, Office of Environmental Information. Report on the Corrosion of Certain Alloys; EPA 260-R-01-002; Washington DC, July 2001; Chapter 9, p 31.
    • (2001) Report on the Corrosion of Certain Alloys , pp. 31
  • 9
    • 0038397304 scopus 로고    scopus 로고
    • The transport of copper through oil-impregnated paper insulation in electrical current transformers and bushings
    • Castle JE, Whitfield TB, Ali M. The transport of copper through oil-impregnated paper insulation in electrical current transformers and bushings. IEEE Electrical Insulation Magazine 2003; 19(l):25-29.
    • (2003) IEEE Electrical Insulation Magazine , vol.19 , Issue.L , pp. 25-29
    • Castle, J.E.1    Whitfield, T.B.2    Ali, M.3
  • 10
    • 47749129144 scopus 로고    scopus 로고
    • The transport of copper though oil impregnated paper insulation in electrical current transformers and bushings
    • pub. The Institute of Materials, Minerals and Mining London
    • Whitefield TB, Castle JE, Ali M. The transport of copper though oil impregnated paper insulation in electrical current transformers and bushings, In Eurocorr2OOO, London, 2000; pub. The Institute of Materials, Minerals and Mining London, 2000; p 123.
    • (2000) Eurocorr2OOO, London , pp. 123
    • Whitefield, T.B.1    Castle, J.E.2    Ali, M.3
  • 14
    • 47749102009 scopus 로고    scopus 로고
    • IEC1125. Unused hydrocarbon-based insulating liquids-Test methods for evaluating the oxidation stability (1 ed.); CEI: 1992; 08.
    • IEC1125. Unused hydrocarbon-based insulating liquids-Test methods for evaluating the oxidation stability (1 ed.); CEI: 1992; Vol. 08.
  • 15
    • 47749109768 scopus 로고    scopus 로고
    • ASTM D974. Test method for acid and base number by color indicator titration. In Annual book of ASTM standards, section 5, 2006; 05.01.
    • ASTM D974. Test method for acid and base number by color indicator titration. In Annual book of ASTM standards, section 5, 2006; Vol. 05.01.
  • 16
    • 0035498059 scopus 로고    scopus 로고
    • The development and use of metal deactivators in the petroleum industry: A review
    • Waynick JA. The development and use of metal deactivators in the petroleum industry: A review. Energy and Fuels 2001; 15(6):1325- 1340.
    • (2001) Energy and Fuels , vol.15 , Issue.6 , pp. 1325-1340
    • Waynick, J.A.1
  • 17
    • 0014788649 scopus 로고
    • Reflection infra-red studies of film formed by benzotriazole on Cu
    • Poling GW. Reflection infra-red studies of film formed by benzotriazole on Cu, Corrosion Science 1970; 10(5):359-370.
    • (1970) Corrosion Science , vol.10 , Issue.5 , pp. 359-370
    • Poling, G.W.1
  • 18
    • 47749084978 scopus 로고    scopus 로고
    • ASTM-D130-94. Standard test method for detection of copper corrosion from petroleum products by the copper strip tarnish test. In Annual book of ASTM standards, section 5, 2006; 05.01.
    • ASTM-D130-94. Standard test method for detection of copper corrosion from petroleum products by the copper strip tarnish test. In Annual book of ASTM standards, section 5, 2006; Vol. 05.01.
  • 19
    • 0037915585 scopus 로고
    • The effect of metals on transformer oils and some methods of protection against adverse effect
    • Wood-Mallock JC, Steiner H, Wood LG. The effect of metals on transformer oils and some methods of protection against adverse effect. Journal of Institute of Petroleum 1958; 44(418):320.
    • (1958) Journal of Institute of Petroleum , vol.44 , Issue.418 , pp. 320
    • Wood-Mallock, J.C.1    Steiner, H.2    Wood, L.G.3
  • 20
    • 34547908942 scopus 로고
    • Mechanism of copper catalysis in insulating oil oxidation
    • Thompson CN. Mechanism of copper catalysis in insulating oil oxidation. Journal of the Institute of Petroleum 1958; 44(417):295-317.
    • (1958) Journal of the Institute of Petroleum , vol.44 , Issue.417 , pp. 295-317
    • Thompson, C.N.1
  • 21
    • 33947229402 scopus 로고    scopus 로고
    • Recent developments in DGA interpretation
    • Duval M. Recent developments in DGA interpretation. CIGRE TF 15/12-01-11.
    • CIGRE TF 15/12-01-11
    • Duval, M.1
  • 22
    • 33947235133 scopus 로고    scopus 로고
    • Oil dependent gas formation in transformer oil
    • Sundkvist K. Oil dependent gas formation in transformer oil. Naphthenics 2002; 1:10.
    • (2002) Naphthenics , vol.1 , pp. 10
    • Sundkvist, K.1
  • 24
    • 5844271122 scopus 로고
    • Copper transfer in refrigeration oil
    • Spauschus HO. Copper transfer in refrigeration oil. ASHRAE Journal 1963; 6:89-92, 140-142.
    • (1963) ASHRAE Journal , vol.6 , Issue.89-92 , pp. 140-142
    • Spauschus, H.O.1
  • 25
    • 0034461411 scopus 로고    scopus 로고
    • Impact of chemistry on the use of polyol ester lubricants in refrigeration
    • Lilje KC. Impact of chemistry on the use of polyol ester lubricants in refrigeration. ASHRAE Transactions 2000; 106(2):661-667.
    • (2000) ASHRAE Transactions , vol.106 , Issue.2 , pp. 661-667
    • Lilje, K.C.1
  • 26
    • 47749157049 scopus 로고
    • Uber die Kupferplaterung in kaltemaschinen
    • Steinle H, Seemann W. Uber die Kupferplaterung in kaltemaschinen. Kaeltetechnik 1951; 3(8):194-197.
    • (1951) Kaeltetechnik , vol.3 , Issue.8 , pp. 194-197
    • Steinle, H.1    Seemann, W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.