메뉴 건너뛰기




Volumn 4, Issue 1, 2006, Pages 81-91

Homemade vs commercial fibrin glue in liver surgery;Colla di fibrina homemade e commerciale in chirurgia epatica

Author keywords

Fibrin glue; Liver surgery; Perioperative bleeding

Indexed keywords

FIBRIN GLUE; FIBRINOGEN;

EID: 47749105644     PISSN: 17232007     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (1)

References (24)
  • 1
    • 0025165987 scopus 로고
    • Fibrin glue: The perfect operative sealant?
    • Gibble JW, Ness PM. Fibrin glue: the perfect operative sealant? Transfusion 1990; 30: 741-7.
    • (1990) Transfusion , vol.30 , pp. 741-747
    • Gibble, J.W.1    Ness, P.M.2
  • 2
    • 0034801567 scopus 로고    scopus 로고
    • Fibrin sealants in surgical practice: An overview
    • Jackson MR. Fibrin sealants in surgical practice: an overview. Am J Surg 2001; 182 (Suppl): 1S-7S.
    • (2001) Am J Surg , vol.182 , Issue.SUPPL.
    • Jackson, M.R.1
  • 3
    • 0030903558 scopus 로고    scopus 로고
    • Fibrin sealant: Scientific rationale, production methods, properties, and current clinical use
    • Radosevich M, Goubran HA, Burnouf T. Fibrin sealant: scientific rationale, production methods, properties, and current clinical use. Vox Sang; 1997; 72: 133-43.
    • (1997) Vox Sang , vol.72 , pp. 133-143
    • Radosevich, M.1    Goubran, H.A.2    Burnouf, T.3
  • 4
    • 0036271290 scopus 로고    scopus 로고
    • Systematic review of the use of fibrin sealant to minimize perioperative allogeneic blood transfusion
    • Carless PA, Anthony DM, Henry DA. Systematic review of the use of fibrin sealant to minimize perioperative allogeneic blood transfusion. Br J Surg 2002; 89: 695-703.
    • (2002) Br J Surg , vol.89 , pp. 695-703
    • Carless, P.A.1    Anthony, D.M.2    Henry, D.A.3
  • 5
    • 0034815920 scopus 로고    scopus 로고
    • New and potential uses of fibrin sealants as an adjunct to surgical hemostasis
    • Jackson MR. New and potential uses of fibrin sealants as an adjunct to surgical hemostasis. Am J Surg 2001; 182 (Suppl): 365-95.
    • (2001) Am J Surg , vol.182 , Issue.SUPPL. , pp. 365-395
    • Jackson, M.R.1
  • 6
    • 0034801306 scopus 로고    scopus 로고
    • The role of fibrin sealant in hemostasis
    • Mankad PS, Codispoti M. The role of fibrin sealant in hemostasis. Am J Surg 182 (Suppl): 21S-28S.
    • Am J Surg , vol.182 , Issue.SUPPL.
    • Mankad, P.S.1    Codispoti, M.2
  • 7
    • 0032761059 scopus 로고    scopus 로고
    • Fibrin sealant: A review of its use in surgery and endoscopy
    • Dunn CJ, Goa KL. Fibrin sealant: a review of its use in surgery and endoscopy. Drugs 1999: 58: 863-86.
    • (1999) Drugs , vol.58 , pp. 863-886
    • Dunn, C.J.1    Goa, K.L.2
  • 8
    • 0034815918 scopus 로고    scopus 로고
    • Commercial fibrin sealants in surgical care
    • Spotnitz WD. Commercial fibrin sealants in surgical care. Am J Surg 2001; 182 (Suppl): 8S-14S.
    • (2001) Am J Surg , vol.182 , Issue.SUPPL.
    • Spotnitz, W.D.1
  • 9
    • 0029152782 scopus 로고    scopus 로고
    • Alving BM, Weinstein JS, Finlayson JE, et al. Fibrin sealant: summary of a conference on characteristics and clinical uses. Transfusion 1995; 35: 783-90.
    • Alving BM, Weinstein JS, Finlayson JE, et al. Fibrin sealant: summary of a conference on characteristics and clinical uses. Transfusion 1995; 35: 783-90.
  • 10
    • 0027250752 scopus 로고
    • The preparation of fibrinogen concentrate for use as a fibrin glue by four different methods
    • De Palma L, Chriss VR, Luban NLC. The preparation of fibrinogen concentrate for use as a fibrin glue by four different methods. Transfusion 1993; 33: 717-20.
    • (1993) Transfusion , vol.33 , pp. 717-720
    • De Palma, L.1    Chriss, V.R.2    Luban, N.L.C.3
  • 11
    • 0035102942 scopus 로고    scopus 로고
    • A novel, automated method of temperature cycling to produce cryoprecipitate
    • Rock G, Berger R, Lange J. et al. A novel, automated method of temperature cycling to produce cryoprecipitate. Transfusion 2001; 41: 232-5.
    • (2001) Transfusion , vol.41 , pp. 232-235
    • Rock, G.1    Berger, R.2    Lange, J.3
  • 12
    • 0031692295 scopus 로고    scopus 로고
    • Vivostat system autologous fibrin sealant: Preliminary study in elective coronary bypass grafting
    • Kjaergard HK, Trumbull HR. Vivostat system autologous fibrin sealant: preliminary study in elective coronary bypass grafting. Am Thorac Surg 1998; 66: 482-6.
    • (1998) Am Thorac Surg , vol.66 , pp. 482-486
    • Kjaergard, H.K.1    Trumbull, H.R.2
  • 13
    • 3142624405 scopus 로고    scopus 로고
    • Fibrin sealant produced by the CryoSeal FS System: Product chemistry, material properties and possible preparation in the autologous preoperative setting
    • Buchta C, Dettke M, Funovies PT, et al. Fibrin sealant produced by the CryoSeal FS System: product chemistry, material properties and possible preparation in the autologous preoperative setting. Vox Sang 2004; 86: 257-62.
    • (2004) Vox Sang , vol.86 , pp. 257-262
    • Buchta, C.1    Dettke, M.2    Funovies, P.T.3
  • 14
    • 0034082046 scopus 로고    scopus 로고
    • Experimental study of a novel fibrin sealant for achieving haemostasis following partial hepatectomy
    • Davidson BR, Burnett S, Javed MS, et al. Experimental study of a novel fibrin sealant for achieving haemostasis following partial hepatectomy. Br J Surg 2000; 87: 790-5.
    • (2000) Br J Surg , vol.87 , pp. 790-795
    • Davidson, B.R.1    Burnett, S.2    Javed, M.S.3
  • 15
    • 0029911693 scopus 로고    scopus 로고
    • Fibrin glue effectiveness and tolerance after elective liver resection: A randomized trial
    • Noun R, Elias D, Balladur P, et al. Fibrin glue effectiveness and tolerance after elective liver resection: a randomized trial. Hepatogastroenterology 1996; 43: 221-4.
    • (1996) Hepatogastroenterology , vol.43 , pp. 221-224
    • Noun, R.1    Elias, D.2    Balladur, P.3
  • 16
    • 0035136634 scopus 로고    scopus 로고
    • Improving operative safety for cirrhotic liver resection
    • Wu CC, Yeh DC, Linn MC, et al. Improving operative safety for cirrhotic liver resection. Br J Surg 2001; 88: 210-5.
    • (2001) Br J Surg , vol.88 , pp. 210-215
    • Wu, C.C.1    Yeh, D.C.2    Linn, M.C.3
  • 17
    • 0029823327 scopus 로고    scopus 로고
    • Proposal of an algorithm to help the choice of the best transfusion strategy
    • Mercuriali F, Inghilleri G. Proposal of an algorithm to help the choice of the best transfusion strategy. Curr Med Res Opin 1996; 13: 465-78.
    • (1996) Curr Med Res Opin , vol.13 , pp. 465-478
    • Mercuriali, F.1    Inghilleri, G.2
  • 18
    • 0027989472 scopus 로고
    • Important factors influencing the strength of autologous fibrin glue: The fibrin concentration and reaction time-comparison of strength with commercial fibrin glue
    • Kjaergard HK, Weiss-Fogh US. Important factors influencing the strength of autologous fibrin glue: the fibrin concentration and reaction time-comparison of strength with commercial fibrin glue. Eur Surg Res 1994; 26: 273-76.
    • (1994) Eur Surg Res , vol.26 , pp. 273-276
    • Kjaergard, H.K.1    Weiss-Fogh, U.S.2
  • 19
    • 0003065739 scopus 로고
    • Is the amount of fibrinogen in cryoprecipitate adequate for fibrin glue? Introducing an improved recycled cryoprecipitate method
    • Wan HL, Huang ST, Floyd DM, et al. Is the amount of fibrinogen in cryoprecipitate adequate for fibrin glue? Introducing an improved recycled cryoprecipitate method. Transfusion 1989; 26 (Suppl): 41S
    • (1989) Transfusion , vol.26 , Issue.SUPPL.
    • Wan, H.L.1    Huang, S.T.2    Floyd, D.M.3
  • 20
    • 0034082767 scopus 로고    scopus 로고
    • Adhesive strength of autologous fibrin glue
    • Yoshida H, Hirozane K, Kamiya A. Adhesive strength of autologous fibrin glue. Biol Pharm Bull 2000; 23: 313-7.
    • (2000) Biol Pharm Bull , vol.23 , pp. 313-317
    • Yoshida, H.1    Hirozane, K.2    Kamiya, A.3
  • 21
    • 0036755264 scopus 로고    scopus 로고
    • Identification of preoperative predictors of intraoperative blood transfusion requirement in orthotopic liver transplantation
    • Pirat A, Sargin D, Torgay A, Arslan G. Identification of preoperative predictors of intraoperative blood transfusion requirement in orthotopic liver transplantation. Transplant Proc 2002; 34, 2153-5.
    • (2002) Transplant Proc , vol.34 , pp. 2153-2155
    • Pirat, A.1    Sargin, D.2    Torgay, A.3    Arslan, G.4
  • 23
    • 7444229717 scopus 로고    scopus 로고
    • Factors affecting blood loss during percutaneous nephrolithotomy: Prospective study
    • Kukreja R, Desai M, Patel S, et al. Factors affecting blood loss during percutaneous nephrolithotomy: prospective study. J Endourol 2004; 18: 715-22.
    • (2004) J Endourol , vol.18 , pp. 715-722
    • Kukreja, R.1    Desai, M.2    Patel, S.3
  • 24
    • 0347674327 scopus 로고    scopus 로고
    • Fibrin glue for wound repair: Facts and fancy
    • Clark RA. Fibrin glue for wound repair: facts and fancy. Thromb Haemost 2003; 90: 1003-6.
    • (2003) Thromb Haemost , vol.90 , pp. 1003-1006
    • Clark, R.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.