메뉴 건너뛰기




Volumn , Issue , 2007, Pages

A hierarchical model for prescribing EMC design targets to the components of a system

Author keywords

Allocated emissions levels; EMC Design targets; Pre compliance testing; Shelf level EMC testing; System level EMC testing; Unit level EMC testing

Indexed keywords

DESIGN; ELECTRIC INVERTERS; HIERARCHICAL SYSTEMS; PLASTIC MOLDS; TARGETS;

EID: 47749092132     PISSN: 10774076     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ISEMC.2007.126     Document Type: Conference Paper
Times cited : (3)

References (5)
  • 1
    • 4644270206 scopus 로고    scopus 로고
    • An Empirical Model for Simulating the System-Level Radiated Emissions Behavior of Interconnected Units and Modules
    • August, Santa Clara, CA
    • H. M. Kudyan, "An Empirical Model for Simulating the System-Level Radiated Emissions Behavior of Interconnected Units and Modules", 2004 IEEE International Symposium on EMC, The Symposium Record, Volume 1, pp. 330-335, August 2004, Santa Clara, CA.
    • (2004) 2004 IEEE International Symposium on EMC, The Symposium Record , vol.1 , pp. 330-335
    • Kudyan, H.M.1
  • 2
    • 33746600325 scopus 로고    scopus 로고
    • Pre-Compliance Testing and Characterization of Equipment Shelf EMC Behavior by Empirical Frequency Response Measurements on the
    • August, Chicago, IL
    • H. M. Kudyan, "Pre-Compliance Testing and Characterization of Equipment Shelf EMC Behavior by Empirical Frequency Response Measurements on the PPB", 2005 IEEE International Symposium on EMC, EMC2005 Proceedings Volume 3, pp. 750-755, August 2005, Chicago, IL.
    • (2005) 2005 IEEE International Symposium on EMC, EMC2005 Proceedings , vol.3 , pp. 750-755
    • Kudyan, H.M.1
  • 3
    • 34047233429 scopus 로고    scopus 로고
    • Prediction of System-Level Emissions Performance via Equipment Shelf Primary Power Bus Frequency Response Characteristics
    • August, Portland, OR
    • H. M. Kudyan, "Prediction of System-Level Emissions Performance via Equipment Shelf Primary Power Bus Frequency Response Characteristics", 2006 IEEE International Symposium on EMC, EMC2006 Proceedings Volume X, pp. xxx-xxx, August 2006, Portland, OR.
    • (2006) 2006 IEEE International Symposium on EMC, EMC2006 Proceedings , vol.10
    • Kudyan, H.M.1
  • 4
    • 47749099607 scopus 로고    scopus 로고
    • CISPR 22, Limits and Methods of Measurement of Radio Disturbance Characteristics of Information Technology Equipment, IEC, CISPR, Geneva.
    • CISPR 22, "Limits and Methods of Measurement of Radio Disturbance Characteristics of Information Technology Equipment," IEC, CISPR, Geneva.
  • 5
    • 47749084584 scopus 로고    scopus 로고
    • Telcordia, GR-1089-CORE, Electromagnetic Compatibility and Electrical Safety- Generic Criteria for Network Telecommunications Equipment, Piscata-way, NJ.
    • Telcordia, GR-1089-CORE, "Electromagnetic Compatibility and Electrical Safety- Generic Criteria for Network Telecommunications Equipment", Piscata-way, NJ.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.