메뉴 건너뛰기




Volumn 30, Issue 6, 2008, Pages 680-686

MicroPET reconstruction with random coincidence correction via a joint Poisson model

Author keywords

CV; FBP; FORE; FWHM; MLE EM; OSEM; PDEM

Indexed keywords

ACOUSTIC EMISSIONS; ALGORITHMS; BLOCK CODES; BOOLEAN FUNCTIONS; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC RADIOGRAPHY; FULL WIDTH AT HALF MAXIMUM; IMAGE ENHANCEMENT; IMAGE PROCESSING; IMAGE QUALITY; IMAGE RECONSTRUCTION; IMAGE SEGMENTATION; ITERATIVE METHODS; MAXIMUM LIKELIHOOD; MAXIMUM LIKELIHOOD ESTIMATION; MEDICAL IMAGING; PLASTIC BOTTLES; POISSON DISTRIBUTION; POISSON EQUATION; POSITRON ANNIHILATION SPECTROSCOPY; RANDOM PROCESSES; REPAIR; RESTORATION; STANDARDS; THERMOGRAPHY (TEMPERATURE MEASUREMENT); TOMOGRAPHY;

EID: 47649119642     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.medengphy.2007.05.013     Document Type: Article
Times cited : (5)

References (17)
  • 2
    • 0034178295 scopus 로고    scopus 로고
    • Comparison of 3-D maximum a posteriori and filtered backprojection algorithms for high-resolution animal imaging with microPET
    • Chatziioannou A., Qi J., Moore A., Annala A., Nguyen K., Leahy R., et al. Comparison of 3-D maximum a posteriori and filtered backprojection algorithms for high-resolution animal imaging with microPET. IEEE Trans Med Imag 19 (2000) 507-512
    • (2000) IEEE Trans Med Imag , vol.19 , pp. 507-512
    • Chatziioannou, A.1    Qi, J.2    Moore, A.3    Annala, A.4    Nguyen, K.5    Leahy, R.6
  • 3
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • Shepp L.A., and Vardi Y. Maximum likelihood reconstruction for emission tomography. IEEE Trans Med Imag MI-1 (1982) 113-122
    • (1982) IEEE Trans Med Imag , vol.MI-1 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 4
    • 0021327145 scopus 로고
    • EM reconstruction algorithms for emission and transmission tomography
    • Lange K., and Carson R.E. EM reconstruction algorithms for emission and transmission tomography. J Comput Assist Tomogr 8 (1984) 306-316
    • (1984) J Comput Assist Tomogr , vol.8 , pp. 306-316
    • Lange, K.1    Carson, R.E.2
  • 5
    • 0010293907 scopus 로고
    • A statistical model for positron emission tomography
    • Vardi Y., Shepp L.A., and Kaufman L. A statistical model for positron emission tomography. J Am Stat Assoc 80 (1985) 8-20
    • (1985) J Am Stat Assoc , vol.80 , pp. 8-20
    • Vardi, Y.1    Shepp, L.A.2    Kaufman, L.3
  • 6
    • 0026392246 scopus 로고
    • Parallelization of the EM algorithm for 3D PET image reconstruction
    • Chen C.M., Lee S.Y., and Cho Z.H. Parallelization of the EM algorithm for 3D PET image reconstruction. IEEE Trans Med Imag 10 (1991) 513-522
    • (1991) IEEE Trans Med Imag , vol.10 , pp. 513-522
    • Chen, C.M.1    Lee, S.Y.2    Cho, Z.H.3
  • 7
    • 0019524035 scopus 로고
    • Quantization in positron emission computed tomography: 4. Effect of accidental coincidences
    • Hoffman E.J., Huang S.C., Phelps M.E., and Kuhl D.E. Quantization in positron emission computed tomography: 4. Effect of accidental coincidences. J Comput Assist Tomogr 5 (1981) 391-400
    • (1981) J Comput Assist Tomogr , vol.5 , pp. 391-400
    • Hoffman, E.J.1    Huang, S.C.2    Phelps, M.E.3    Kuhl, D.E.4
  • 8
    • 0022888626 scopus 로고
    • Quantization in positron emission computed tomography: 7 a technique to reduce noise in accidental coincidence measurements and coincidence efficiency calibration
    • Casey M.E., and Hoffman E.J. Quantization in positron emission computed tomography: 7 a technique to reduce noise in accidental coincidence measurements and coincidence efficiency calibration. J Comput Assist Tomogr 10 (1986) 845-850
    • (1986) J Comput Assist Tomogr , vol.10 , pp. 845-850
    • Casey, M.E.1    Hoffman, E.J.2
  • 9
    • 0034593782 scopus 로고    scopus 로고
    • Random correction for positron emission tomography using singles count rates
    • Rokitta O., Casey M., Wienhard K., and Pietrzyk U. Random correction for positron emission tomography using singles count rates. IEEE Nucl Sci Symp Conf Rec 3 (2000) 1737-1740
    • (2000) IEEE Nucl Sci Symp Conf Rec , vol.3 , pp. 1737-1740
    • Rokitta, O.1    Casey, M.2    Wienhard, K.3    Pietrzyk, U.4
  • 10
    • 0026121689 scopus 로고
    • Corrections for accidental coincidences and attenuation in maximum-likelihood image reconstruction for positron-emission tomography
    • Politte D.G., and Snyder D.L. Corrections for accidental coincidences and attenuation in maximum-likelihood image reconstruction for positron-emission tomography. IEEE Trans Med Imag. 10 (1991) 82-89
    • (1991) IEEE Trans Med Imag. , vol.10 , pp. 82-89
    • Politte, D.G.1    Snyder, D.L.2
  • 11
    • 0027644026 scopus 로고
    • On complete-data spaces for PET reconstruction algorithms
    • Fessler J.A., Clinthorne N.H., and Rogers W.L. On complete-data spaces for PET reconstruction algorithms. IEEE Trans Nucl Sci 40 (1993) 1055-1061
    • (1993) IEEE Trans Nucl Sci , vol.40 , pp. 1055-1061
    • Fessler, J.A.1    Clinthorne, N.H.2    Rogers, W.L.3
  • 13
    • 0031987376 scopus 로고    scopus 로고
    • Cross-reference weighted least square estimates for positron emission tomography
    • Lu H.H.S., Chen C.M., and Yang I.H. Cross-reference weighted least square estimates for positron emission tomography. IEEE Trans Med Imag 17 (1998) 1-8
    • (1998) IEEE Trans Med Imag , vol.17 , pp. 1-8
    • Lu, H.H.S.1    Chen, C.M.2    Yang, I.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.