메뉴 건너뛰기




Volumn 395, Issue 1-2, 2008, Pages 51-56

Prostate-specific antigen detection by using a reusable amperometric immunosensor based on reversible binding and leasing of HRP-anti-PSA from phenylboronic acid modified electrode

Author keywords

Amperometric immunosensor; Electrocatalytic; Immunocomplex; Phenylboronic acid assembled monolayer; Prostate specific antigen; Reusable

Indexed keywords

ANTIBODY; BENZENEBORONIC ACID; ENZYME CONJUGATED PROSTATE SPECIFIC ANTIBODY; GOLD; HYDROGEN PEROXIDE; PROSTATE SPECIFIC ANTIGEN;

EID: 47649111641     PISSN: 00098981     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cca.2008.04.031     Document Type: Article
Times cited : (47)

References (37)
  • 3
    • 0142072508 scopus 로고    scopus 로고
    • Reagentless amperometric immunosensors based on direct electrochemistry of horseradish peroxidase for determination of carcinoma antigen-125
    • Dai Z., Yan F., Chen J., and Ju H.X. Reagentless amperometric immunosensors based on direct electrochemistry of horseradish peroxidase for determination of carcinoma antigen-125. Anal Chem 75 (2003) 5429-5434
    • (2003) Anal Chem , vol.75 , pp. 5429-5434
    • Dai, Z.1    Yan, F.2    Chen, J.3    Ju, H.X.4
  • 4
    • 33746200886 scopus 로고    scopus 로고
    • A disposable electrochemical immunosensor for flow injection immunoassay of carcinoembryonic antigen
    • Wu J., Tang J.H., Dai Z., Yan F., Ju H.X., and El Murr N. A disposable electrochemical immunosensor for flow injection immunoassay of carcinoembryonic antigen. Biosens Bioelectron 22 (2006) 102-108
    • (2006) Biosens Bioelectron , vol.22 , pp. 102-108
    • Wu, J.1    Tang, J.H.2    Dai, Z.3    Yan, F.4    Ju, H.X.5    El Murr, N.6
  • 5
    • 33845416939 scopus 로고    scopus 로고
    • Highly sensitive amperometric immunosensors for microcystin detection in algae
    • Campas M., and Marty J.L. Highly sensitive amperometric immunosensors for microcystin detection in algae. Biosens Bioelectron 22 (2007) 1034-1040
    • (2007) Biosens Bioelectron , vol.22 , pp. 1034-1040
    • Campas, M.1    Marty, J.L.2
  • 6
    • 33846196163 scopus 로고    scopus 로고
    • Amperometric immunosensor for the detection of anti-West Nile virus IgG using a photoactive copolymer
    • Ionescu R.E., Cosnier S., Herzog G., et al. Amperometric immunosensor for the detection of anti-West Nile virus IgG using a photoactive copolymer. Enzyme Microb Technol 40 (2007) 403-408
    • (2007) Enzyme Microb Technol , vol.40 , pp. 403-408
    • Ionescu, R.E.1    Cosnier, S.2    Herzog, G.3
  • 7
    • 33845467525 scopus 로고    scopus 로고
    • New antibodies immobilization system into a graphite-polysulfone membrane for amperometric immunosensors
    • Ordonez S.S., and Fabregas E. New antibodies immobilization system into a graphite-polysulfone membrane for amperometric immunosensors. Biosens Bioelectron 22 (2007) 965-972
    • (2007) Biosens Bioelectron , vol.22 , pp. 965-972
    • Ordonez, S.S.1    Fabregas, E.2
  • 8
    • 0035499756 scopus 로고    scopus 로고
    • Electrochemical and quartz crystal microbalance detection of the cholera toxin employing horseradish peroxidase and GM1-functionalized liposomes
    • Alfonta L., Willner I., Throckmorton D.J., and Singh A.K. Electrochemical and quartz crystal microbalance detection of the cholera toxin employing horseradish peroxidase and GM1-functionalized liposomes. Anal Chem 73 (2001) 5287-5295
    • (2001) Anal Chem , vol.73 , pp. 5287-5295
    • Alfonta, L.1    Willner, I.2    Throckmorton, D.J.3    Singh, A.K.4
  • 9
    • 0037106516 scopus 로고    scopus 로고
    • Immunobiosensor chips for detection of Escherichia coli O157:H7 using electrochemical impedance spectroscopy
    • Ruan C.M., Yang L.J., and Li Y.B. Immunobiosensor chips for detection of Escherichia coli O157:H7 using electrochemical impedance spectroscopy. Anal Chem 74 (2002) 4814-4820
    • (2002) Anal Chem , vol.74 , pp. 4814-4820
    • Ruan, C.M.1    Yang, L.J.2    Li, Y.B.3
  • 10
    • 0043269702 scopus 로고    scopus 로고
    • Probing biomolecular interactions at conductive and semiconductive surfaces by impedance spectroscopy: Routes to impedimetric immunosensors, DNA-sensors, and enzyme biosensors
    • Katz E., and Willner I. Probing biomolecular interactions at conductive and semiconductive surfaces by impedance spectroscopy: Routes to impedimetric immunosensors, DNA-sensors, and enzyme biosensors. Electroanalysis 15 (2003) 913-947
    • (2003) Electroanalysis , vol.15 , pp. 913-947
    • Katz, E.1    Willner, I.2
  • 11
    • 33947582815 scopus 로고    scopus 로고
    • An impedimetric immunosensor for the label-free detection of bisphenol A
    • Rahman M.A., Shiddiky M.J.A., Park J.S., and Shim Y.B. An impedimetric immunosensor for the label-free detection of bisphenol A. Biosens Bioelectron 22 (2007) 2464-2470
    • (2007) Biosens Bioelectron , vol.22 , pp. 2464-2470
    • Rahman, M.A.1    Shiddiky, M.J.A.2    Park, J.S.3    Shim, Y.B.4
  • 12
    • 4744372123 scopus 로고    scopus 로고
    • Disposable noncompetitive immunosensor for free and total prostate-specific antigen based on capacitance measurement
    • Fernandez-Sanchez C., McNeil C.J., Rawson K., and Nilsson O. Disposable noncompetitive immunosensor for free and total prostate-specific antigen based on capacitance measurement. Anal Chem 76 (2004) 5649-5656
    • (2004) Anal Chem , vol.76 , pp. 5649-5656
    • Fernandez-Sanchez, C.1    McNeil, C.J.2    Rawson, K.3    Nilsson, O.4
  • 13
    • 33644819949 scopus 로고    scopus 로고
    • A reusable capacitive immunosensor for carcinoembryonic antigen (CEA) detection using thiourea modified gold electrode
    • Limbut W., Kanatharana P., Mattiasson B., Asawatreratanakul P., and Thavarungkul P. A reusable capacitive immunosensor for carcinoembryonic antigen (CEA) detection using thiourea modified gold electrode. Anal Chim Acta 561 (2006) 55-61
    • (2006) Anal Chim Acta , vol.561 , pp. 55-61
    • Limbut, W.1    Kanatharana, P.2    Mattiasson, B.3    Asawatreratanakul, P.4    Thavarungkul, P.5
  • 14
    • 4444250434 scopus 로고    scopus 로고
    • Chemiluminescent immunosensor for CA19-9 based on antigen immobilization on a cross-linked chitosan membrane
    • Lin J.H., Yan F., Hu X.Y., and Ju H.X. Chemiluminescent immunosensor for CA19-9 based on antigen immobilization on a cross-linked chitosan membrane. J Immunol Methods 291 (2004) 165-174
    • (2004) J Immunol Methods , vol.291 , pp. 165-174
    • Lin, J.H.1    Yan, F.2    Hu, X.Y.3    Ju, H.X.4
  • 15
    • 33646920643 scopus 로고    scopus 로고
    • Flow-injection chemiluminescent immunoassay for alpha-fetoprotein based on epoxysilane modified glass microbeads
    • Fu Z.F., Hao C., Fei X.Q., and Ju H.X. Flow-injection chemiluminescent immunoassay for alpha-fetoprotein based on epoxysilane modified glass microbeads. J Immunol Methods 312 (2006) 61-67
    • (2006) J Immunol Methods , vol.312 , pp. 61-67
    • Fu, Z.F.1    Hao, C.2    Fei, X.Q.3    Ju, H.X.4
  • 16
    • 33846581584 scopus 로고    scopus 로고
    • Layer-by-layer hydroxymethyl ferrocene modified sensor for one-step flow/stop-flow injection amperometric immunoassay of alpha-fetoprotein
    • Dai Z., Serban S., Ju H.X., and El Murra N. Layer-by-layer hydroxymethyl ferrocene modified sensor for one-step flow/stop-flow injection amperometric immunoassay of alpha-fetoprotein. Biosens Bioelectron 22 (2007) 1700-1706
    • (2007) Biosens Bioelectron , vol.22 , pp. 1700-1706
    • Dai, Z.1    Serban, S.2    Ju, H.X.3    El Murra, N.4
  • 17
    • 0027447614 scopus 로고
    • Prostate-specific antigen: biochemistry, analytical methods, and clinical application
    • Armbruster D.A. Prostate-specific antigen: biochemistry, analytical methods, and clinical application. Clin Chem 39 (1993) 181-195
    • (1993) Clin Chem , vol.39 , pp. 181-195
    • Armbruster, D.A.1
  • 18
    • 0030162849 scopus 로고    scopus 로고
    • PSA and prostate cancer diagnosis
    • Savage P., and Waxman J. PSA and prostate cancer diagnosis. Eur J Cancer 32A (1996) 1097-1099
    • (1996) Eur J Cancer , vol.32 A , pp. 1097-1099
    • Savage, P.1    Waxman, J.2
  • 19
    • 0029764376 scopus 로고    scopus 로고
    • Free-to-total prostate-specific antigen ratio as a single test for detection of significant stage T1c prostate cancer
    • Elgamal A.A., Cornillie F.J., Van Poppel H.P., Van de Voorde W.M., McCabe R., and Baert L.V. Free-to-total prostate-specific antigen ratio as a single test for detection of significant stage T1c prostate cancer. J Urol 156 (1996) 1042-1049
    • (1996) J Urol , vol.156 , pp. 1042-1049
    • Elgamal, A.A.1    Cornillie, F.J.2    Van Poppel, H.P.3    Van de Voorde, W.M.4    McCabe, R.5    Baert, L.V.6
  • 20
    • 0028957468 scopus 로고
    • Thiophilic gels: applications in flow-injection immunoassay for macromolecules and haptens
    • Palmer D.A., and Miller J.N. Thiophilic gels: applications in flow-injection immunoassay for macromolecules and haptens. Anal Chim Acta 303 (1995) 223-230
    • (1995) Anal Chim Acta , vol.303 , pp. 223-230
    • Palmer, D.A.1    Miller, J.N.2
  • 21
    • 23944456321 scopus 로고    scopus 로고
    • Development of isotopic and non-isotopic microwell based immunoassays for hCG using I-125 and biotin labeled hCG
    • Basu A., Shrivastav T.G., and Maitra S.K. Development of isotopic and non-isotopic microwell based immunoassays for hCG using I-125 and biotin labeled hCG. J Immunoass Immunochem 26 (2005) 313-324
    • (2005) J Immunoass Immunochem , vol.26 , pp. 313-324
    • Basu, A.1    Shrivastav, T.G.2    Maitra, S.K.3
  • 22
    • 17644385929 scopus 로고    scopus 로고
    • Surface plasmon fluorescence measurements of human chorionic gonadotrophin: role of antibody orientation in obtaining enhanced sensitivity and limit of detection
    • Vareiro M.L.M., Liu J., Knoll W., Zak K., Williams D., and Jenkins A.T.A. Surface plasmon fluorescence measurements of human chorionic gonadotrophin: role of antibody orientation in obtaining enhanced sensitivity and limit of detection. Anal Chem 77 (2005) 2426-2431
    • (2005) Anal Chem , vol.77 , pp. 2426-2431
    • Vareiro, M.L.M.1    Liu, J.2    Knoll, W.3    Zak, K.4    Williams, D.5    Jenkins, A.T.A.6
  • 23
    • 0037093740 scopus 로고    scopus 로고
    • Amperometric biosensors for detection of the prostate cancer marker (PSA)
    • Sarkar P., Pal P.S., Ghosh D., Setford S.J., and Tothill I.E. Amperometric biosensors for detection of the prostate cancer marker (PSA). Int J Pharm 238 (2002) 1-9
    • (2002) Int J Pharm , vol.238 , pp. 1-9
    • Sarkar, P.1    Pal, P.S.2    Ghosh, D.3    Setford, S.J.4    Tothill, I.E.5
  • 24
    • 22044439309 scopus 로고    scopus 로고
    • Affinity interactions between phenylboronic acid-carrying self-assembled monolayers and flavin adenine dinucleotide or horseradish peroxidase
    • Liu S.Q., Wollenberger U., Halámek J., et al. Affinity interactions between phenylboronic acid-carrying self-assembled monolayers and flavin adenine dinucleotide or horseradish peroxidase. Chem Eur J 11 (2005) 4239-4246
    • (2005) Chem Eur J , vol.11 , pp. 4239-4246
    • Liu, S.Q.1    Wollenberger, U.2    Halámek, J.3
  • 25
    • 27844432592 scopus 로고    scopus 로고
    • Phenylboronic acid self-assembled layer on glassy carbon electrode for recognition of glycoprotein peroxidase
    • Liu S.Q., Miller B., and Chen A. Phenylboronic acid self-assembled layer on glassy carbon electrode for recognition of glycoprotein peroxidase. Electrochem Commun 7 (2005) 1232-1236
    • (2005) Electrochem Commun , vol.7 , pp. 1232-1236
    • Liu, S.Q.1    Miller, B.2    Chen, A.3
  • 26
    • 33744983704 scopus 로고    scopus 로고
    • Specific binding of glycoproteins with poly(aniline boronic acid) thin film
    • Liu S.Q., Bakovic L., and Chen A. Specific binding of glycoproteins with poly(aniline boronic acid) thin film. J Electroanal Chem 591 (2006) 210-216
    • (2006) J Electroanal Chem , vol.591 , pp. 210-216
    • Liu, S.Q.1    Bakovic, L.2    Chen, A.3
  • 27
    • 41149145641 scopus 로고    scopus 로고
    • A reusable electrochemical immunosensor for carcinoembryonic antigen via molecular recognition of glycoprotein antibody by phenylboronic acid self-assembly layer on gold
    • Zhang X.T., Wu Y.F., Tu Y.F., and Liu S.Q. A reusable electrochemical immunosensor for carcinoembryonic antigen via molecular recognition of glycoprotein antibody by phenylboronic acid self-assembly layer on gold. Analyst 132 (2008) 485-492
    • (2008) Analyst , vol.132 , pp. 485-492
    • Zhang, X.T.1    Wu, Y.F.2    Tu, Y.F.3    Liu, S.Q.4
  • 28
    • 0025652133 scopus 로고
    • Determination of protein covalently bound to agarose supports using bicinchoninic acid
    • Stich T.M. Determination of protein covalently bound to agarose supports using bicinchoninic acid. Anal Biochem 191 (1990) 343-346
    • (1990) Anal Biochem , vol.191 , pp. 343-346
    • Stich, T.M.1
  • 29
    • 0032515430 scopus 로고    scopus 로고
    • Controlling interfacial electron-transfer kinetics of cytochrome c with mixed self-assembled monolayers
    • El Kasmi A., Wallace J.M., Bowden E.F., Binet S.M., and Linderman R.J. Controlling interfacial electron-transfer kinetics of cytochrome c with mixed self-assembled monolayers. J Am Chem Soc 120 (1998) 225-226
    • (1998) J Am Chem Soc , vol.120 , pp. 225-226
    • El Kasmi, A.1    Wallace, J.M.2    Bowden, E.F.3    Binet, S.M.4    Linderman, R.J.5
  • 30
    • 0031277223 scopus 로고    scopus 로고
    • Investigation of the electrode reaction of cytochrome c through mixed self-assembled monolayers of alkanethiols on gold(111) surfaces
    • Arnold S., Feng Z.Q., Kakiuchi T., Knoll W., and Niki K. Investigation of the electrode reaction of cytochrome c through mixed self-assembled monolayers of alkanethiols on gold(111) surfaces. J Electroanal Chem 438 (1997) 91-97
    • (1997) J Electroanal Chem , vol.438 , pp. 91-97
    • Arnold, S.1    Feng, Z.Q.2    Kakiuchi, T.3    Knoll, W.4    Niki, K.5
  • 31
    • 0031272909 scopus 로고    scopus 로고
    • Electrochemical responses of cytochrome c on a gold electrode modified with mixed monolayers of 3-mercaptopropionic acid and n-alkanethiol
    • Sato Y., and Mizutani F. Electrochemical responses of cytochrome c on a gold electrode modified with mixed monolayers of 3-mercaptopropionic acid and n-alkanethiol. J Electroanal Chem 438 (1997) 99-104
    • (1997) J Electroanal Chem , vol.438 , pp. 99-104
    • Sato, Y.1    Mizutani, F.2
  • 32
    • 33846188525 scopus 로고    scopus 로고
    • A sensitive impedance immunosensor based on functionalized gold nanoparticle-protein composite films for probing apolipoprotein A-I
    • Zhang S., Huang F., Liu B.H., Ding J.J., Xu X., and Kong J.L. A sensitive impedance immunosensor based on functionalized gold nanoparticle-protein composite films for probing apolipoprotein A-I. Talanta 71 (2007) 874-881
    • (2007) Talanta , vol.71 , pp. 874-881
    • Zhang, S.1    Huang, F.2    Liu, B.H.3    Ding, J.J.4    Xu, X.5    Kong, J.L.6
  • 33
    • 0035077986 scopus 로고    scopus 로고
    • Phenylboronic acid-salicylhydroxamic acid biconjugates. 1. A novel boronic acid complex for protein immobilization
    • Stolowitz M.L., Ahlem C., Hughes K.A., et al. Phenylboronic acid-salicylhydroxamic acid biconjugates. 1. A novel boronic acid complex for protein immobilization. Bioconjug Chem 12 (2001) 229-239
    • (2001) Bioconjug Chem , vol.12 , pp. 229-239
    • Stolowitz, M.L.1    Ahlem, C.2    Hughes, K.A.3
  • 34
    • 35448966139 scopus 로고    scopus 로고
    • Disposable electrochemical immunosensor diagnosis device based on nanoparticle probe and immunochromatographic strip
    • Liu G.D., Lin Y.Y., Wang J., Wu H., Wai C.M., and Lin Y.H. Disposable electrochemical immunosensor diagnosis device based on nanoparticle probe and immunochromatographic strip. Anal Chem 79 (2007) 7644-7653
    • (2007) Anal Chem , vol.79 , pp. 7644-7653
    • Liu, G.D.1    Lin, Y.Y.2    Wang, J.3    Wu, H.4    Wai, C.M.5    Lin, Y.H.6
  • 35
    • 39049118856 scopus 로고    scopus 로고
    • Integrated microfluidic systems with an immunosensor modified with carbon nanotubes for detection of prostate specific antigen (PSA) in human serum samples
    • Panini N.V., Messina G.A., Salinas E., Fernández H., and Raba J. Integrated microfluidic systems with an immunosensor modified with carbon nanotubes for detection of prostate specific antigen (PSA) in human serum samples. Biosens Bioelectron 23 (2008) 1145-1151
    • (2008) Biosens Bioelectron , vol.23 , pp. 1145-1151
    • Panini, N.V.1    Messina, G.A.2    Salinas, E.3    Fernández, H.4    Raba, J.5
  • 36
    • 0141615980 scopus 로고    scopus 로고
    • Modification of a thin gold film with boronic acid membrane and its application to a saccharide sensor based on surface plasmon resonance
    • Soh N., Sonezaki M., and Imato T. Modification of a thin gold film with boronic acid membrane and its application to a saccharide sensor based on surface plasmon resonance. Electroanalysis 15 (2003) 1281-1290
    • (2003) Electroanalysis , vol.15 , pp. 1281-1290
    • Soh, N.1    Sonezaki, M.2    Imato, T.3
  • 37
    • 2742574088 scopus 로고
    • Polyol complexes and structure of the benzeneboronate ion
    • Lorand J.P., and Edwards J.O. Polyol complexes and structure of the benzeneboronate ion. J Org Chem 24 (1959) 769-774
    • (1959) J Org Chem , vol.24 , pp. 769-774
    • Lorand, J.P.1    Edwards, J.O.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.