메뉴 건너뛰기




Volumn 53, Issue 13, 2008, Pages 3447-3462

Transit dose contributions to intracavitary and interstitial PDR brachytherapy treatments

Author keywords

[No Author keywords available]

Indexed keywords

DOSE RATES; DWELL POSITIONS; HIGH-DOSE-RATE (HDR); INTERSTITIAL BRACHYTHERAPY; PDR BRACHYTHERAPY; RADIATION SOURCES; TRANSIT DOSE;

EID: 47649101729     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/53/13/003     Document Type: Article
Times cited : (5)

References (11)
  • 1
    • 0027304238 scopus 로고
    • The transit dose component of high dose rate brachytherapy: Direct measurements and clinical implications
    • Bastin K T, Podgorsak M B and Thomadsen B R 1993 The transit dose component of high dose rate brachytherapy: direct measurements and clinical implications Int. J. Radiat. Oncol. Biol. Phys. 26 695-702
    • (1993) Int. J. Radiat. Oncol. Biol. Phys. , vol.26 , Issue.4 , pp. 695-702
    • Bastin, K.T.1    Podgorsak, M.B.2    Thomadsen, B.R.3
  • 2
    • 0030760034 scopus 로고    scopus 로고
    • Monte Carlo calculated dose distribution for endovascular HDR brachytherapy with Ir-192
    • Dries W J F 1997 Monte Carlo calculated dose distribution for endovascular HDR brachytherapy with Ir-192 Radiot. Oncol. 45 77-82
    • (1997) Radiot. Oncol. , vol.45 , Issue.1 , pp. 77-82
    • Dries, W.J.F.1
  • 4
  • 5
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43
    • Nath R, Anderson L L, Luxton G, Weaver K A, Williamson J F and Meigooni A S 1995 Dosimetry of interstitial brachytherapy sources: recommendations of the AAPM Radiation Therapy Committee Task Group No. 43 Med. Phys. 22 209-234
    • (1995) Med. Phys. , vol.22 , Issue.2 , pp. 209-234
    • Nath, R.1    Anderson, L.L.2    Luxton, G.3    Weaver, K.A.4    Williamson, J.F.5    Meigooni, A.S.6
  • 8
    • 0028285969 scopus 로고
    • Effect of anisotropy corrections on the dynamic dose calculations in high dose rate (HDR) brachytherapy
    • Sang-Hyun C and Muller-Runkel R 1994 Effect of anisotropy corrections on the dynamic dose calculations in high dose rate (HDR) brachytherapy Phys. Med. Biol. 39 1181-8
    • (1994) Phys. Med. Biol. , vol.39 , Issue.7 , pp. 1181-1188
    • Sang-Hyun, C.1    Muller-Runkel, R.2
  • 9
    • 0000351363 scopus 로고
    • Treatment of cancer of the cervix uteri-a revised Manchester method
    • Tod M and Meredith W J 1953 Treatment of cancer of the cervix uteri-a revised Manchester method Br. J. Radiol. 26 252-7
    • (1953) Br. J. Radiol. , vol.26 , pp. 252-257
    • Tod, M.1    Meredith, W.J.2
  • 11
    • 0035126054 scopus 로고    scopus 로고
    • Transit dose of an Ir-192 high dose rate brachytherapy stepping source
    • Wong T P Y, Fernando W, Johnston P N and Bubb I F 2001 Transit dose of an Ir-192 high dose rate brachytherapy stepping source Phys. Med. Biol. 46 323-31
    • (2001) Phys. Med. Biol. , vol.46 , Issue.2 , pp. 323-331
    • Wong, T.P.Y.1    Fernando, W.2    Johnston, P.N.3    Bubb, I.F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.