메뉴 건너뛰기




Volumn 36, Issue 7, 2008, Pages 607-614

The influence on the images of computed tomography caused by the use of artificial cranial reconstructive materials

Author keywords

Artifact; Artificial bone; Computed tomography; Cranioplasty; Hydroxyapatite polymthyl metacrylate composite

Indexed keywords

HYDROXYAPATITE; POLY(METHYL METHACRYLATE); TITANIUM;

EID: 47549116181     PISSN: 03012603     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (6)

References (12)
  • 1
    • 0018498316 scopus 로고
    • Current concepts in cranioplasty
    • Beumer III J : Current concepts in cranioplasty. J Prosthet Dent 42 : 67-77, 1979
    • (1979) J Prosthet Dent , vol.42 , pp. 67-77
    • Beumer III, J.1
  • 4
    • 34548423296 scopus 로고    scopus 로고
    • A 12 month in-vivo study on the response of bone to a hydroxyapatite - polymethylmethacrylate cranioplasty composite
    • Itokawa H, Hiraide T, Moriya M, Fujimoto M, Nagashima G, Suzuki R, Fujimoto T : A 12 month in-vivo study on the response of bone to a hydroxyapatite - polymethylmethacrylate cranioplasty composite. Biomaterials 28 : 4922-4927, 2007
    • (2007) Biomaterials , vol.28 , pp. 4922-4927
    • Itokawa, H.1    Hiraide, T.2    Moriya, M.3    Fujimoto, M.4    Nagashima, G.5    Suzuki, R.6    Fujimoto, T.7
  • 5
    • 0033458787 scopus 로고    scopus 로고
    • A prospective study of computer-aided design and manufacture of titanium plate for cranioplasty and its clinical outcome
    • Joffe J, Harris M, Kahugu F, Nicoll S, Linney A, Richards R. A prospective study of computer-aided design and manufacture of titanium plate for cranioplasty and its clinical outcome. Br J Neurosurg 13 : 576-580, 1999
    • (1999) Br J Neurosurg , vol.13 , pp. 576-580
    • Joffe, J.1    Harris, M.2    Kahugu, F.3    Nicoll, S.4    Linney, A.5    Richards, R.6
  • 6
    • 0023224718 scopus 로고
    • Reduction of CT artifacts caused by metallic implants
    • Kalender WA, Hebel R, Ebersberger J : Reduction of CT artifacts caused by metallic implants. Radiology 164 : 576-577, 1987
    • (1987) Radiology , vol.164 , pp. 576-577
    • Kalender, W.A.1    Hebel, R.2    Ebersberger, J.3
  • 8
    • 0035673513 scopus 로고    scopus 로고
    • Kiefer VH : Brain SPECT artifacts having metallic ctanioplasty
    • Michael T, Hackett T, Wei-Jen Shih, Kiefer VH : Brain SPECT artifacts having metallic ctanioplasty. J Nucl Med 29 : 189-192, 2001
    • (2001) J Nucl Med , vol.29 , pp. 189-192
    • Michael, T.1    Hackett, T.2    Jen Shih, W.3
  • 10
    • 0021344890 scopus 로고
    • No Shinkei Geka 12 : 246-252, 1984
    • (1984) No Shinkei Geka , vol.12 , pp. 246-252
  • 11
    • 0032770953 scopus 로고    scopus 로고
    • Treatment of large complex cranial bone defects by using hydroxyapatite ceramic implants
    • Ono I, Tateshita T, Satou M, Sasaki T, Matsumoto M, Kodama N : Treatment of large complex cranial bone defects by using hydroxyapatite ceramic implants. Plast Reconstr Surg 104 : 339-349, 1999
    • (1999) Plast Reconstr Surg , vol.104 , pp. 339-349
    • Ono, I.1    Tateshita, T.2    Satou, M.3    Sasaki, T.4    Matsumoto, M.5    Kodama, N.6
  • 12
    • 0023866456 scopus 로고
    • Evaluation of CT techniques for reducing artifacts in the presence of metallic orthopedic implants
    • Robertson DD, Weiss PJ, Fishman EK, Magid D, Walker PS : Evaluation of CT techniques for reducing artifacts in the presence of metallic orthopedic implants. J Comput Assist Tomogr 12 : 236-241, 1988
    • (1988) J Comput Assist Tomogr , vol.12 , pp. 236-241
    • Robertson, D.D.1    Weiss, P.J.2    Fishman, E.K.3    Magid, D.4    Walker, P.S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.