메뉴 건너뛰기




Volumn 11, Issue 4, 2004, Pages 233-236

Effects of self-expanding metal stents on work of breathing in patients with tracheobronchial stenosis

Author keywords

Airway obstruction; Airway stenting; Pulmonary function testing; Work of breathing

Indexed keywords

ADULT; AGED; AIRWAY OBSTRUCTION; ARTICLE; BREATHING; CLINICAL ARTICLE; FATIGUE; FEMALE; HUMAN; LUNG FUNCTION TEST; MALE; PRIORITY JOURNAL; PROSPECTIVE STUDY; RECANALIZATION; RESPIRATORY FAILURE; STENOSIS; STENT; TRACHEOBRONCHIAL STENOSIS;

EID: 4744357521     PISSN: 10708030     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.lab.0000136177.21662.8e     Document Type: Article
Times cited : (9)

References (17)
  • 1
    • 0000222295 scopus 로고    scopus 로고
    • Tracheobronchial stents
    • Bolliger CT, Mathur PN, eds. New York, Basel: Karger
    • Freitag L. Tracheobronchial stents. In: Bolliger CT, Mathur PN, eds. Interventional Bronchoscopy. New York, Basel: Karger; 2000:171-186.
    • (2000) Interventional Bronchoscopy , pp. 171-186
    • Freitag, L.1
  • 2
    • 4744350626 scopus 로고
    • Flexible versus rigid bronchoscopic placement of tracheobronchial prosthesis. Pro flexible bronchoscopy
    • Becker HD. Flexible versus rigid bronchoscopic placement of tracheobronchial prosthesis. Pro flexible bronchoscopy. Journal of Bronchology. 1995;2:251-254.
    • (1995) Journal of Bronchology , vol.2 , pp. 251-254
    • Becker, H.D.1
  • 3
    • 0025124330 scopus 로고
    • A dedicated tracheobronchial stent
    • Dumon JF. A dedicated tracheobronchial stent. Chest. 1990;97:328-332.
    • (1990) Chest , vol.97 , pp. 328-332
    • Dumon, J.F.1
  • 4
    • 0027501220 scopus 로고
    • Silicone stents in the management of inoperable tracheobronchial stenosis: Indications and limitations
    • Bolliger CT, Probst R, Tschopp K, et al. Silicone stents in the management of inoperable tracheobronchial stenosis: indications and limitations. Chest. 1993;104:1653-1659.
    • (1993) Chest , vol.104 , pp. 1653-1659
    • Bolliger, C.T.1    Probst, R.2    Tschopp, K.3
  • 5
    • 0034885888 scopus 로고    scopus 로고
    • Successful bronchoscopic placement of tracheobronchial stents without fluoroscopy
    • Herth F, Becker HD, LoCicero J, et al. Successful bronchoscopic placement of tracheobronchial stents without fluoroscopy. Chest. 2001;119:1910-1912.
    • (2001) Chest , vol.119 , pp. 1910-1912
    • Herth, F.1    Becker, H.D.2    LoCicero, J.3
  • 6
    • 0032459761 scopus 로고    scopus 로고
    • Tracheobronchial F stents
    • Strausz J, ed. Department of Pneumology, Thoraxklinik Heidelberg, Germany
    • Freitag L. Tracheobronchial F stents. In: Strausz J, ed. European Respiratory Monograph. Department of Pneumology, Thoraxklinik Heidelberg, Germany. 1998:79-105.
    • (1998) European Respiratory Monograph , pp. 79-105
    • Freitag, L.1
  • 7
    • 0028937426 scopus 로고
    • Efficacy of tracheal and bronchial stent placement on respiratory functional tests
    • Vergnon JM, Costes F, Bayon MC, et al. Efficacy of tracheal and bronchial stent placement on respiratory functional tests. Chest. 1995;107:741-746.
    • (1995) Chest , vol.107 , pp. 741-746
    • Vergnon, J.M.1    Costes, F.2    Bayon, M.C.3
  • 8
    • 0026707823 scopus 로고
    • Physiologic studies of tracheobronchial stents in airways obstruction
    • Gelb AF, Zamel N, Colchen A, et al. Physiologic studies of tracheobronchial stents in airways obstruction. Am Rev Respir Dis. 1992;146:1088-1090.
    • (1992) Am Rev Respir Dis , vol.146 , pp. 1088-1090
    • Gelb, A.F.1    Zamel, N.2    Colchen, A.3
  • 10
    • 0036644465 scopus 로고    scopus 로고
    • ATS statement. Guidelines for the six-minute walk test
    • ATS statement. Guidelines for the six-minute walk test. Am J Respir Crit Care Med. 2002;166:111-117.
    • (2002) Am J Respir Crit Care Med , vol.166 , pp. 111-117
  • 11
    • 0020469123 scopus 로고
    • A simple method for assessing the validity of the esophageal balloon technique
    • Baydur A. A simple method for assessing the validity of the esophageal balloon technique. Am Rev Respir Dis. 1982;126:788-791.
    • (1982) Am Rev Respir Dis , vol.126 , pp. 788-791
    • Baydur, A.1
  • 12
    • 0027984746 scopus 로고
    • A new respiratory monitor that enables accurate measurement of work of breathing: A validation study
    • Blanch PB. A new respiratory monitor that enables accurate measurement of work of breathing: a validation study. Respir Care. 1994;39:897-905.
    • (1994) Respir Care , vol.39 , pp. 897-905
    • Blanch, P.B.1
  • 13
    • 0024536667 scopus 로고
    • Use of silicone stents in the management of airway problems
    • Cooper JD, Pearson FG, Patterson GA, et al. Use of silicone stents in the management of airway problems. Ann Thorac Surg. 1989;47:371-378.
    • (1989) Ann Thorac Surg , vol.47 , pp. 371-378
    • Cooper, J.D.1    Pearson, F.G.2    Patterson, G.A.3
  • 14
    • 0030759604 scopus 로고    scopus 로고
    • Implantation of Accuflex and Strecker stents in malignant bronchial stenosis by flexible bronchoscopy
    • Hauck RW, Lembeck RM, Emslander HP, et al. Implantation of Accuflex and Strecker stents in malignant bronchial stenosis by flexible bronchoscopy. Chest. 1997;112:134-144.
    • (1997) Chest , vol.112 , pp. 134-144
    • Hauck, R.W.1    Lembeck, R.M.2    Emslander, H.P.3
  • 15
    • 0029883830 scopus 로고    scopus 로고
    • Treatment of large airway obstruction in lung cancer using expandable metal stents inserted under direct vision via the fiberoptic bronchoscope
    • Wilson GE, Walshaw MJ, Hind CRK. Treatment of large airway obstruction in lung cancer using expandable metal stents inserted under direct vision via the fiberoptic bronchoscope. Thorax. 1996;51:248-252.
    • (1996) Thorax , vol.51 , pp. 248-252
    • Wilson, G.E.1    Walshaw, M.J.2    Hind, C.R.K.3
  • 16
    • 0027243938 scopus 로고
    • Malignant tracheobronchial obstructive lesions: Treatment with Gianturco expandable metallic stents
    • Sawada S, Tanigawa N, Kobayashi M, et al. Malignant tracheobronchial obstructive lesions: treatment with Gianturco expandable metallic stents. Radiology. 1993;188:203-208.
    • (1993) Radiology , vol.188 , pp. 203-208
    • Sawada, S.1    Tanigawa, N.2    Kobayashi, M.3
  • 17
    • 0032964770 scopus 로고    scopus 로고
    • Pulmonary function improves after expandable metal stent placement für benign airway obstruction
    • Eisner MD, Gordon RL, Webb WR, et al. Pulmonary function improves after expandable metal stent placement für benign airway obstruction. Chest. 115:1006-1011.
    • Chest , vol.115 , pp. 1006-1011
    • Eisner, M.D.1    Gordon, R.L.2    Webb, W.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.