메뉴 건너뛰기




Volumn 63, Issue 2, 2004, Pages 242-246

Percutaneous closure of patent foramen ovale guided by intracardiac echocardiography and performed through the transfemoral approach in the presence of previously placed inferior vena cava filters: A case series

Author keywords

Cardiac catheterization; Interatrial septum; Intracardiac echo; Patent foramen ovale; Venous thrombosis

Indexed keywords

ADULT; AGED; ARTICLE; CASE REPORT; CASE STUDY; DEVICE; ECHOCARDIOGRAPHY; FEMALE; HEART ATRIUM SEPTUM DEFECT; HEART CATHETERIZATION; HIGH RISK PATIENT; HUMAN; IMPLANTATION; INFERIOR CAVA VEIN; MALE; RISK BENEFIT ANALYSIS; STROKE; SURGICAL APPROACH; VEIN THROMBOSIS; VENA CAVA FILTER; WOUND CLOSURE;

EID: 4744339336     PISSN: 15221946     EISSN: None     Source Type: Journal    
DOI: 10.1002/ccd.20174     Document Type: Article
Times cited : (12)

References (15)
  • 1
    • 0026564953 scopus 로고
    • Transcatheter closure of patent foramen ovale after presumed paradoxical embolism
    • Bridges ND, Hellenbrand W, Latson L, et al. Transcatheter closure of patent foramen ovale after presumed paradoxical embolism. Circulation 1992;86:1902-1908.
    • (1992) Circulation , vol.86 , pp. 1902-1908
    • Bridges, N.D.1    Hellenbrand, W.2    Latson, L.3
  • 2
    • 0034003573 scopus 로고    scopus 로고
    • Percutaneous closure of patent foramen ovale in patients with paradoxical embolism
    • Windecker S, Wahl A, Chatterjee T, et al. Percutaneous closure of patent foramen ovale in patients with paradoxical embolism. Circulation 2000;101:893-898.
    • (2000) Circulation , vol.101 , pp. 893-898
    • Windecker, S.1    Wahl, A.2    Chatterjee, T.3
  • 3
    • 0034083893 scopus 로고    scopus 로고
    • Closure of patent foramen ovale for paradoxical emboli: Intermediate-term risk of recurrent neurological events following transcatheter device placement
    • Hung J, Landzberg MJ, Jenkins KJ, et al. Closure of patent foramen ovale for paradoxical emboli: intermediate-term risk of recurrent neurological events following transcatheter device placement. J Am Coll Cardiol 2000;35:1311-1316.
    • (2000) J Am Coll Cardiol , vol.35 , pp. 1311-1316
    • Hung, J.1    Landzberg, M.J.2    Jenkins, K.J.3
  • 4
    • 0028075189 scopus 로고
    • Greenfield inferior vena cava filter dislodged during central venous catheter placement
    • Marelich GP, Tharatt RS. Greenfield inferior vena cava filter dislodged during central venous catheter placement. Chest 1994;106:957-959.
    • (1994) Chest , vol.106 , pp. 957-959
    • Marelich, G.P.1    Tharatt, R.S.2
  • 5
    • 0030066659 scopus 로고    scopus 로고
    • Guide-wire entrapment by inferior vena cava filters: In vitro evaluation
    • Kaufman JA, Thomas JW, Geller SC, et al. Guide-wire entrapment by inferior vena cava filters: in vitro evaluation. Radiology 1996;198:71-76.
    • (1996) Radiology , vol.198 , pp. 71-76
    • Kaufman, J.A.1    Thomas, J.W.2    Geller, S.C.3
  • 6
    • 0034850292 scopus 로고    scopus 로고
    • Platypnea-orthodeoxia: Management by transcatheter buttoned device implantation
    • Rao PS, et al. Platypnea-orthodeoxia: management by transcatheter buttoned device implantation. Catheter Cardiovasc Interv 2001;54:77-88.
    • (2001) Catheter Cardiovasc Interv , vol.54 , pp. 77-88
    • Rao, P.S.1
  • 7
  • 8
    • 0033001012 scopus 로고    scopus 로고
    • Prevention of recurrent cerebral ischemic events in patients with patent foramen ovale and cryptogenic strokes or transient ischemic attacks
    • Cujec B, Mainra R, Johnson DH. Prevention of recurrent cerebral ischemic events in patients with patent foramen ovale and cryptogenic strokes or transient ischemic attacks. Can J Cardiol 1999;15:57-64.
    • (1999) Can J Cardiol , vol.15 , pp. 57-64
    • Cujec, B.1    Mainra, R.2    Johnson, D.H.3
  • 9
    • 0035833927 scopus 로고    scopus 로고
    • Prognosis after percutaneous closure of patent foramen ovale for paradoxical embolism
    • Wahl A, et al. Prognosis after percutaneous closure of patent foramen ovale for paradoxical embolism. Neurology 2001;57:1330-1332.
    • (2001) Neurology , vol.57 , pp. 1330-1332
    • Wahl, A.1
  • 13
    • 0036678194 scopus 로고    scopus 로고
    • A novel technique to prevent displacement of inferior vena cava filter during cardiac catheterization with subsequent transcatheter closure of a patent foramen ovale in a patient with cryptogenic shock
    • Recto MR, Sobczyk WL. A novel technique to prevent displacement of inferior vena cava filter during cardiac catheterization with subsequent transcatheter closure of a patent foramen ovale in a patient with cryptogenic shock. J Invas Cardiol 2002;14:471-473.
    • (2002) J Invas Cardiol , vol.14 , pp. 471-473
    • Recto, M.R.1    Sobczyk, W.L.2
  • 14
    • 0036142672 scopus 로고    scopus 로고
    • Transesophageal echocardiography for quantifying size of patent foramen ovale in patients with cryptogenic cerebrovascular events
    • Schuchlenz HW, Weihs W, Beitzke A, Stein JI, Gamillscheg A, Rehak P. Transesophageal echocardiography for quantifying size of patent foramen ovale in patients with cryptogenic cerebrovascular events. Stroke 2002;33:293-296.
    • (2002) Stroke , vol.33 , pp. 293-296
    • Schuchlenz, H.W.1    Weihs, W.2    Beitzke, A.3    Stein, J.I.4    Gamillscheg, A.5    Rehak, P.6
  • 15
    • 0037448797 scopus 로고    scopus 로고
    • Intracardiac echocardiography is superior to conventional monitoring for guiding device closure of interatrial communications
    • Bartel T, Konorza T, Arjumand J, Ebradlidze T, Eggebrecht H, Caspari G, Neudorf U, Erbel R. Intracardiac echocardiography is superior to conventional monitoring for guiding device closure of interatrial communications. Circulation 2003;107:795-797.
    • (2003) Circulation , vol.107 , pp. 795-797
    • Bartel, T.1    Konorza, T.2    Arjumand, J.3    Ebradlidze, T.4    Eggebrecht, H.5    Caspari, G.6    Neudorf, U.7    Erbel, R.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.