메뉴 건너뛰기




Volumn 2, Issue , 2008, Pages

Independent lung ventilation in a newborn with asymmetric acute lung injury due to respiratory syncytial virus: A case report

Author keywords

[No Author keywords available]

Indexed keywords

BRONCHODILATING AGENT; CORTICOSTEROID;

EID: 47349114116     PISSN: 17521947     EISSN: 17521947     Source Type: Journal    
DOI: 10.1186/1752-1947-2-212     Document Type: Article
Times cited : (6)

References (9)
  • 1
    • 19044364582 scopus 로고    scopus 로고
    • Independent high-frequency oscillatory ventilation in the management of asymmetric acute lung injury
    • 10.1213/01.ANE.0000151161.36330.CF 15920215
    • Terragni P Rosboch GL Como E Menaldo E Tealdi A Borasio P Davini O Viale AG Ranieri VM Independent high-frequency oscillatory ventilation in the management of asymmetric acute lung injury Anesth Analg 2005, 100:1793-1796 10.1213/01.ANE.0000151161.36330.CF 15920215
    • (2005) Anesth Analg , vol.100 , pp. 1793-1796
    • Terragni, P.1    Rosboch, G.L.2    Como, E.3    Menaldo, E.4    Tealdi, A.5    Borasio, P.6    Davini, O.7    Viale, A.G.8    Ranieri, V.M.9
  • 2
    • 33750132530 scopus 로고    scopus 로고
    • Diagnosis and management of bronchiolitis
    • American Academy of Pediatrics Subcommittee on 10.1542/peds.2006-2223 17015575
    • American Academy of Pediatrics Subcommittee on Diagnosis and Management of Bronchiolitis Diagnosis and management of bronchiolitis Pediatrics 2006, 118:1774-1793 10.1542/peds.2006-2223 17015575
    • (2006) Pediatrics , vol.118 , pp. 1774-1793
  • 3
    • 0035214778 scopus 로고    scopus 로고
    • Independent lung ventilation in patients with unilateral pulmonary contusion: Monitoring with compliance and EtCO2
    • 10.1007/s00134-001-1149-6 11797020
    • Cinnella G Dambrosio M Brienza N Giuliani R Bruno F Fiore T Brienza A Independent lung ventilation in patients with unilateral pulmonary contusion: Monitoring with compliance and EtCO2 Intensive Care Med 2001, 27:1860-1867 10.1007/s00134-001-1149-6 11797020
    • (2001) Intensive Care Med , vol.27 , pp. 1860-1867
    • Cinnella, G.1    Dambrosio, M.2    Brienza, N.3    Giuliani, R.4    Bruno, F.5    Fiore, T.6    Brienza, A.7
  • 4
    • 28944445502 scopus 로고    scopus 로고
    • Tidal volume reduction in patients with acute lung injury when plateau pressures are not high
    • 10.1164/rccm.200501-048CP 16081547
    • Hager D Krishnan J Hayden D Bower R Tidal volume reduction in patients with acute lung injury when plateau pressures are not high Am J Respir Crit Care Med 2005, 172:1241-1245 10.1164/rccm.200501-048CP 16081547
    • (2005) Am J Respir Crit Care Med , vol.172 , pp. 1241-1245
    • Hager, D.1    Krishnan, J.2    Hayden, D.3    Bower, R.4
  • 5
    • 33847413174 scopus 로고    scopus 로고
    • Is there a safe plateau pressure in ARDS? The right heart only knows
    • 10.1007/s00134-007-0552-z 17268795
    • Jardin F Vieillard-Baron A Is there a safe plateau pressure in ARDS? The right heart only knows Intensive Care Med 2007, 33:444-447 10.1007/ s00134-007-0552-z 17268795
    • (2007) Intensive Care Med , vol.33 , pp. 444-447
    • Jardin, F.1    Vieillard-Baron, A.2
  • 6
    • 85034670908 scopus 로고
    • Feasibility of asynchronous independent lung high-frequency oscillatory ventilation in the management of acute hypoxemic respiratory failure: A case report
    • 3677770
    • Graciano AL Barton P Luckett PM Morriss F Sommerauer JF Toro-Fiqueroa LO Feasibility of asynchronous independent lung high-frequency oscillatory ventilation in the management of acute hypoxemic respiratory failure: A case report Crit Care Med 1987, 15:1160-1161 3677770
    • (1987) Crit Care Med , vol.15 , pp. 1160-1161
    • Graciano, A.L.1    Barton, P.2    Luckett, P.M.3    Morriss, F.4    Sommerauer, J.F.5    Toro-Fiqueroa, L.O.6
  • 7
    • 0030008576 scopus 로고    scopus 로고
    • Single-lung ventilation in pediatric patients
    • 10.1097/00000542-199606000-00028 8669693
    • Hammer GB Manos SJ Smith BM Skargard ED Brodsky JB Single-lung ventilation in pediatric patients Anesthesiology 1996, 84:1503-1506 10.1097/00000542-199606000-00028 8669693
    • (1996) Anesthesiology , vol.84 , pp. 1503-1506
    • Hammer, G.B.1    Manos, S.J.2    Smith, B.M.3    Skargard, E.D.4    Brodsky, J.B.5
  • 8
    • 14944376786 scopus 로고    scopus 로고
    • One lung ventilation in infants and children: Experience with Marraro double lumen tube
    • 10.1111/j.1460-9592.2005.01421.x 15725317
    • Pawar DK Marraro GA One lung ventilation in infants and children: experience with Marraro double lumen tube Paediatr Anaesth 2005, 15:204-208 10.1111/j.1460-9592.2005.01421.x 15725317
    • (2005) Paediatr Anaesth , vol.15 , pp. 204-208
    • Pawar, D.K.1    Marraro, G.A.2
  • 9
    • 0242425796 scopus 로고    scopus 로고
    • Differentiated HFO and CMV for independent lung ventilation in a pediatric patient
    • 10.1007/s00134-003-1949-y 14534775
    • Plotz FB Hassing MB Sibarani-Ponsen RD Markerhorst DG Differentiated HFO and CMV for independent lung ventilation in a pediatric patient Intensive Care Med 2003, 29:1855 10.1007/s00134-003-1949-y 14534775
    • (2003) Intensive Care Med , vol.29 , pp. 1855
    • Plotz, F.B.1    Hassing, M.B.2    Sibarani-Ponsen, R.D.3    Markerhorst, D.G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.