메뉴 건너뛰기




Volumn , Issue , 2006, Pages 615-618

Relationship between PD-induced electromagnetic wave measured with UHF method and charge quantity obtained by PD current waveform in model GIS

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRIC CORONA; ELECTRIC DISCHARGES; ELECTROMAGNETIC WAVES; GEOGRAPHIC INFORMATION SYSTEMS; INSULATING MATERIALS; PARTIAL DISCHARGES; SENSITIVITY ANALYSIS; UHF DEVICES;

EID: 47349106762     PISSN: 00849162     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/CEIDP.2006.312007     Document Type: Conference Paper
Times cited : (47)

References (7)
  • 1
    • 50549096544 scopus 로고    scopus 로고
    • e.g., the 14th International Symposium on High Voltage Engineering (ISH2005), Session F Asset management of HV equipment & Session G Diagnostics and on-line monitoring, Beijing, China, 2005
    • e.g., the 14th International Symposium on High Voltage Engineering (ISH2005), Session F "Asset management of HV equipment" & Session G "Diagnostics and on-line monitoring", Beijing, China, 2005
  • 2
    • 50549103264 scopus 로고    scopus 로고
    • Study on combining UHF techniques with the IEC60270 standard for monitoring partial discharge of HV plant
    • L.Yang, B.G.Stewart, A.J.Reid, M.D.Judd and R.A.Fouracre, "Study on combining UHF techniques with the IEC60270 standard for monitoring partial discharge of HV plant", the 14th ISH (ISH2005), G-0117, 2005
    • (2005) the 14th ISH (ISH2005)
    • Yang, L.1    Stewart, B.G.2    Reid, A.J.3    Judd, M.D.4    Fouracre, R.A.5
  • 3
    • 35348827565 scopus 로고    scopus 로고
    • An integrated measurement strategy for simultaneous fault identification: Combining the UHF and IEC60270 techniques
    • A.J.Reid, L.Yang, M.D.Jud, B.G.Stewart and R.A.Fouracre, "An integrated measurement strategy for simultaneous fault identification: combining the UHF and IEC60270 techniques"' the 14th ISH (ISH2005), G058, 2005
    • (2005) the 14th ISH (ISH2005)
    • Reid, A.J.1    Yang, L.2    Jud, M.D.3    Stewart, B.G.4    Fouracre, R.A.5
  • 4
    • 50549088279 scopus 로고    scopus 로고
    • A unique sensitivity verification combined with real-time PD identification method
    • T.Hoshino, S.Maruyama, Y.Hoshina and M.Hanai, "A unique sensitivity verification combined with real-time PD identification method", the 14th ISH (ISH2005), F-004, 2005
    • (2005) the 14th ISH (ISH2005)
    • Hoshino, T.1    Maruyama, S.2    Hoshina, Y.3    Hanai, M.4
  • 5
    • 54949131071 scopus 로고    scopus 로고
    • Influence of GIS tank size on discrimination of discharge type based on PD-induced electromagnetic wave with UHF method
    • ISH, Delft, Netherlands
    • S.Ohtsuka, Y.Kunitake, M.Onomoto, S.Yuasa, S.Okabe and M.Hikita, "Influence of GIS tank size on discrimination of discharge type based on PD-induced electromagnetic wave with UHF method", the 13th ISH (ISH2003), No.459, Delft, Netherlands, 2003
    • (2003) the 13th ISH , Issue.459
    • Ohtsuka, S.1    Kunitake, Y.2    Onomoto, M.3    Yuasa, S.4    Okabe, S.5    Hikita, M.6
  • 6
    • 33745650479 scopus 로고    scopus 로고
    • Influence of GIS tank size on first-incoming PD-induced electromagnetic wave in terms of risk assessment of GIS
    • in Japanese
    • S.Ohtsuka, M.Onomoto, T.Teshima, S.Okabe, S.Kaneko and M.Hikita, "Influence of GIS tank size on first-incoming PD-induced electromagnetic wave in terms of risk assessment of GIS"' IEEJ Trans. PE, Vol. 1247 No. 11 pp. 1365-13727 2004 (in Japanese)
    • (2004) IEEJ Trans. PE , vol.1247 , Issue.11 , pp. 1365-13727
    • Ohtsuka, S.1    Onomoto, M.2    Teshima, T.3    Okabe, S.4    Kaneko, S.5    Hikita, M.6
  • 7
    • 50549098188 scopus 로고    scopus 로고
    • Concept to be successfully accomplished for insulation diagnosis of gas-insulated power apparatus detected by PD signals and relation between charge quantity of PD and the induced-electromagnetic wave measured with UHF method
    • Korea
    • S.Ohtsuka, T.Teshima, Y.Hayashi, S.Matsumoto and M.Hikita "Concept to be successfully accomplished for insulation diagnosis of gas-insulated power apparatus detected by PD signals and relation between charge quantity of PD and the induced-electromagnetic wave measured with UHF method'" CMD2006, Chanrgwon, Korea, 2006
    • (2006) Chanrgwon , vol.CMD2006
    • Ohtsuka, S.1    Teshima, T.2    Hayashi, Y.3    Matsumoto, S.4    Hikita, M.5