메뉴 건너뛰기




Volumn , Issue , 2007, Pages 134-137

Influence of absorbed gas in silicone rubber on electrical tree initiation

Author keywords

[No Author keywords available]

Indexed keywords

BUILDING MATERIALS; ELASTOMERS; ELECTRIC LINES; POWER TRANSMISSION; RUBBER; SILICONES;

EID: 47349105500     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICSD.2007.4290771     Document Type: Conference Paper
Times cited : (7)

References (6)
  • 1
    • 47349128047 scopus 로고    scopus 로고
    • Development of Cold-Shrinkable Joints with Carrier Pipes for HV Cables
    • H.Suzuki, S.Kobayashi, T.Ono, D.Muto, H.Kurihara, S.Tanaka, "Development of Cold-Shrinkable Joints with Carrier Pipes for HV Cables", T. IEE Japan Vol.120-B, No11, pp.1408-1415, 2000
    • (2000) T. IEE Japan , vol.120-B , Issue.NO11 , pp. 1408-1415
    • Suzuki, H.1    Kobayashi, S.2    Ono, T.3    Muto, D.4    Kurihara, H.5    Tanaka, S.6
  • 2
    • 47349118541 scopus 로고    scopus 로고
    • Influence of Vacuum Evacuation on Electrical Tree Initiation in Silicone Rubber
    • Y.Kamiya, Y. Muramoto, N.Shimizu, "Influence of Vacuum Evacuation on Electrical Tree Initiation in Silicone Rubber", 2006 IEEE CEIDP Annual Report, pp712-715, 2006
    • (2006) IEEE CEIDP Annual Report , pp. 712-715
    • Kamiya, Y.1    Muramoto, Y.2    Shimizu, N.3
  • 3
    • 0032179625 scopus 로고    scopus 로고
    • Electrical Tree Initiation
    • N.Shimizu and C.Laurent, "Electrical Tree Initiation", IEEE Trans. DEI Vol.5, No5, pp651-659, 1998
    • (1998) IEEE Trans. DEI , vol.5 , Issue.NO5 , pp. 651-659
    • Shimizu, N.1    Laurent, C.2
  • 4
    • 0035306896 scopus 로고    scopus 로고
    • Effect of Liquid Impregnation on Electrical Tree Initiation in XLPE
    • N.Shimizu and H.Tanaka, "Effect of Liquid Impregnation on Electrical Tree Initiation in XLPE", IEEE Trans. DEI Vol.8, No.2, pp239-243, 2001
    • (2001) IEEE Trans. DEI , vol.8 , Issue.2 , pp. 239-243
    • Shimizu, N.1    Tanaka, H.2
  • 5
    • 0035176230 scopus 로고    scopus 로고
    • Suppression of High Field Degradation and Electrical Tree by n-Hexane Impregnation in XLPE
    • N.Shimizu and T.Suzuki, "Suppression of High Field Degradation and Electrical Tree by n-Hexane Impregnation in XLPE", 2001 CEIDP Annual Report, pp253-256, 2001
    • (2001) CEIDP Annual Report , pp. 253-256
    • Shimizu, N.1    Suzuki, T.2
  • 6
    • 0242655942 scopus 로고    scopus 로고
    • Electroluminescence and Degradation in PE caused by Electron Impact
    • N.Shimizu and N.Nagura, T.Suzuki and A.Tanida, "Electroluminescence and Degradation in PE caused by Electron Impact", 2003 IEEE CEIDP Annual Report, pp361-364, 2003
    • (2003) IEEE CEIDP Annual Report , pp. 361-364
    • Shimizu, N.1    Nagura, N.2    Suzuki, T.3    Tanida, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.