메뉴 건너뛰기




Volumn 43, Issue 8, 2008, Pages 952-960

Spent caustic oxidation using electro-generated Fenton's reagent in a batch reactor

Author keywords

Electro Fenton; Electrochemical oxidation; Fenton reagent; Spent caustic

Indexed keywords

BATCH REACTORS; CONCENTRATION (PROCESS); IRON; MAGNESIUM PRINTING PLATES; NONMETALS; OXYGEN; PLATES (STRUCTURAL COMPONENTS); RATE CONSTANTS; SOLUTIONS; WASTEWATER TREATMENT;

EID: 47349085688     PISSN: 10934529     EISSN: 15324117     Source Type: Journal    
DOI: 10.1080/10934520801974533     Document Type: Conference Paper
Times cited : (15)

References (14)
  • 1
    • 47349121294 scopus 로고    scopus 로고
    • Carlos, T.M.S.; Maugans, C.B. Wet Air Oxidation of Refinery Spent Caustic: A Refinery Case Study; Technical Report No. 427, NPRA Conference, San Antonio, Texas, September 12, 2000.
    • Carlos, T.M.S.; Maugans, C.B. Wet Air Oxidation of Refinery Spent Caustic: A Refinery Case Study; Technical Report No. 427, NPRA Conference, San Antonio, Texas, September 12, 2000.
  • 2
    • 0035062770 scopus 로고    scopus 로고
    • Treatment of Olefin Plant Spent Caustic by Combination of Neutralization and Fenton Reaction
    • Weng, S.-H.; Sa, H.-S. Treatment of Olefin Plant Spent Caustic by Combination of Neutralization and Fenton Reaction. Water Res. 2000, 35, 2017-2021.
    • (2000) Water Res , vol.35 , pp. 2017-2021
    • Weng, S.-H.1    Sa, H.-S.2
  • 3
    • 33947326426 scopus 로고
    • Hydrogen peroxide catalytic oxidation of refractory organics in municipal waste waters
    • Bishop, D.F.; Stern, G.; Fleishman, M.; Marshall, L.S. Hydrogen peroxide catalytic oxidation of refractory organics in municipal waste waters. Ind. Eng. Chem. Proc. Design Deve. 1968, 7, 1110-1117.
    • (1968) Ind. Eng. Chem. Proc. Design Deve , vol.7 , pp. 1110-1117
    • Bishop, D.F.1    Stern, G.2    Fleishman, M.3    Marshall, L.S.4
  • 4
    • 4444263691 scopus 로고    scopus 로고
    • Electro-Fenton as a feasible advanced treatment process to produce reclaimed water
    • Durán Moreno, A.; Frontana Uribe, B.A.; Ramirez Zamora, R.M. Electro-Fenton as a feasible advanced treatment process to produce reclaimed water. Water Sci. Technol. 2004, 50, 83-90.
    • (2004) Water Sci. Technol , vol.50 , pp. 83-90
    • Durán Moreno, A.1    Frontana Uribe, B.A.2    Ramirez Zamora, R.M.3
  • 5
    • 1542789741 scopus 로고
    • Fenton's Reagent Revisited
    • Walling, C. Fenton's Reagent Revisited. Acc. Chem. Res. 1974, 8, 125.
    • (1974) Acc. Chem. Res , vol.8 , pp. 125
    • Walling, C.1
  • 8
    • 0004276469 scopus 로고
    • Oregon State University Book Store, Corvallis, OR, USA
    • Levenspiel, O. The Chemical Reactor Omnibook. Oregon State University Book Store, Corvallis, OR, USA, 1979.
    • (1979) The Chemical Reactor Omnibook
    • Levenspiel, O.1
  • 11
    • 47349101591 scopus 로고    scopus 로고
    • ENAP Refinerías Aconcagua, Con Con, Chile. Internal communication, 2007.
    • ENAP Refinerías Aconcagua, Con Con, Chile. Internal communication, 2007.
  • 12
    • 0032972987 scopus 로고    scopus 로고
    • Characteristics of pchlorophenol oxidation by Fenton's reagent
    • Kwon, B.G.; Lee, D.S.; Kang, N.; Yoon Y., Characteristics of pchlorophenol oxidation by Fenton's reagent; Water Res. 1998, 33(9), 2110-2118.
    • (1998) Water Res , vol.33 , Issue.9 , pp. 2110-2118
    • Kwon, B.G.1    Lee, D.S.2    Kang, N.3    Yoon, Y.4
  • 13
    • 0034579009 scopus 로고    scopus 로고
    • Treatment of landfill leachate by combined Electro-Fenton oxidation and sequencing batch reactor method
    • Lin S.H.; Chang, C.C. Treatment of landfill leachate by combined Electro-Fenton oxidation and sequencing batch reactor method. Water Res. 2000, 34(17), 4243-4249.
    • (2000) Water Res , vol.34 , Issue.17 , pp. 4243-4249
    • Lin, S.H.1    Chang, C.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.