-
1
-
-
0020963921
-
The first decade
-
A survey of finite element analysis in orthopaedics biomechanics
-
Huiskes R, Chao EYS, A survey of finite element analysis in orthopaedics biomechanics: The first decade, J Biomech 16:385-409, 1983.
-
(1983)
J Biomech
, vol.16
, pp. 385-409
-
-
Huiskes, R.1
Chao, E.Y.S.2
-
2
-
-
0025495260
-
Automated three-dimensional finite element modeling of bone: A new method
-
Keyak JH, Meagher JM, Skinner HB, Mote CD, Automated three-dimensional finite element modeling of bone: A new method, J Biomed Eng 12 389-397, 1990.
-
(1990)
J Biomed Eng
, vol.12
, pp. 389-397
-
-
Keyak, J.H.1
Meagher, J.M.2
Skinner, H.B.3
Mote, C.D.4
-
3
-
-
0345215180
-
A comparative study on different methods of automatic mesh generation of human femurs
-
Viceconti M, Bellingeri L, Cristofolini L, Toni A, A comparative study on different methods of automatic mesh generation of human femurs, Med Eng Phys 20:1-10, 1998.
-
(1998)
Med Eng Phys
, vol.20
, pp. 1-10
-
-
Viceconti, M.1
Bellingeri, L.2
Cristofolini, L.3
Toni, A.4
-
4
-
-
0032909127
-
CT data sets surface extraction for biomechanical modeling of long bones
-
Viceconti M, Zannoni C, Testi D, Cappello A, CT data sets surface extraction for biomechanical modeling of long bones, Comput Methods Programs Biomed 59:159-166, 1999.
-
(1999)
Comput Methods Programs Biomed
, vol.59
, pp. 159-166
-
-
Viceconti, M.1
Zannoni, C.2
Testi, D.3
Cappello, A.4
-
5
-
-
0344440923
-
An improved method for the automatic mapping of computer tomography numbers onto finite element models
-
Taddei F, Pancanti A, Viceconti M, An improved method for the automatic mapping of computer tomography numbers onto finite element models, Med Eng Phys 26:61-69, 2004.
-
(2004)
Med Eng Phys
, vol.26
, pp. 61-69
-
-
Taddei, F.1
Pancanti, A.2
Viceconti, M.3
-
6
-
-
0023224718
-
Reduction of CT artifact caused by metallic implants
-
Kalender WA, Hebel R, Ebersberger J, Reduction of CT artifact caused by metallic implants, Radiology 164:576-577, 1987.
-
(1987)
Radiology
, vol.164
, pp. 576-577
-
-
Kalender, W.A.1
Hebel, R.2
Ebersberger, J.3
-
7
-
-
0030270864
-
Iterative deblurring for CT metal artifact reduction
-
Wang G, Snyder DL, O'Sullivan JA, Vannier MW, Iterative deblurring for CT metal artifact reduction, IEEE Trans Med Imaging 15 657-664, 1996.
-
(1996)
IEEE Trans Med Imaging
, vol.15
, pp. 657-664
-
-
Wang, G.1
Snyder, D.L.2
O'Sullivan, J.A.3
Vannier, M.W.4
-
8
-
-
0033999350
-
Improved MR imaging for patients with metallic implants
-
Viano AM, Gronemeyer SA, Haliloglu M, Hoffer FA, Improved MR imaging for patients with metallic implants, Magn Reson Imaging 18 287-295, 2000.
-
(2000)
Magn Reson Imaging
, vol.18
, pp. 287-295
-
-
Viano, A.M.1
Gronemeyer, S.A.2
Haliloglu, M.3
Hoffer, F.A.4
-
9
-
-
0036210548
-
Technical considerations: CT and MR imaging in the postoperative orthopedic patient
-
White LM, Buckwalter KA, Technical considerations: CT and MR imaging in the postoperative orthopedic patient, Semin Musculoskelet Radiol 6:5-17, 2002.
-
(2002)
Semin Musculoskelet Radiol
, vol.6
, pp. 5-17
-
-
White, L.M.1
Buckwalter, K.A.2
-
10
-
-
2542496945
-
A pragmatic approach to metal artifact reduction in CT: Merging of metal artifact reduced images
-
Watzke O, Kalender WA, A pragmatic approach to metal artifact reduction in CT: Merging of metal artifact reduced images, Eur Radiol 14 849-856, 2004.
-
(2004)
Eur Radiol
, vol.14
, pp. 849-856
-
-
Watzke, O.1
Kalender, W.A.2
-
11
-
-
33645774093
-
Preliminary study of correction of original metal artifacts due to I-125 seeds in post-implant dosimetry for prostate permanent implant brachytherapy
-
Takahashi Y, Mori S, Kozuka T, Gomi K, Nose T, Tahara T, Oguchi M, Yamashita T, Preliminary study of correction of original metal artifacts due to I-125 seeds in post-implant dosimetry for prostate permanent implant brachytherapy, Radiat Med 24:133-138, 2006.
-
(2006)
Radiat Med
, vol.24
, pp. 133-138
-
-
Takahashi, Y.1
Mori, S.2
Kozuka, T.3
Gomi, K.4
Nose, T.5
Tahara, T.6
Oguchi, M.7
Yamashita, T.8
-
12
-
-
0032216420
-
Analysis of titanium induced CT artifacts in the development of biomechanical finite element models
-
Zannoni C, Viceconti M, Pierotti L, Cappello A, Analysis of titanium induced CT artifacts in the development of biomechanical finite element models, Med Eng Phys 20:653-659, 1998.
-
(1998)
Med Eng Phys
, vol.20
, pp. 653-659
-
-
Zannoni, C.1
Viceconti, M.2
Pierotti, L.3
Cappello, A.4
-
13
-
-
0031457272
-
Cross-section radiographic analysis of 10 retrieved titanium alloy press-fit femoral endoprostheses
-
Lester K, Cross-section radiographic analysis of 10 retrieved titanium alloy press-fit femoral endoprostheses, J Arthroplasty 12 930-937, 1997.
-
(1997)
J Arthroplasty
, vol.12
, pp. 930-937
-
-
Lester, K.1
-
14
-
-
47149103661
-
-
Persson A, On the stress distribution of cylindrical elastic bodies in contact, PhD dissertation, Chalmers University of Technology, Gothenburg, Sweden, 1964.
-
Persson A, On the stress distribution of cylindrical elastic bodies in contact, PhD dissertation, Chalmers University of Technology, Gothenburg, Sweden, 1964.
-
-
-
-
15
-
-
0035976642
-
Solutions for contact in pinned connections
-
Iyer K, Solutions for contact in pinned connections, Int J Solids Struct 38:9133-9148, 2001.
-
(2001)
Int J Solids Struct
, vol.38
, pp. 9133-9148
-
-
Iyer, K.1
-
16
-
-
0035872809
-
The state of stress induced by the plane frictionless cylindrical contact. Parts I & II. The case of elastic similarity. The general case (elastic dissimilarity)
-
Ciavarella M, Decuzzi P, The state of stress induced by the plane frictionless cylindrical contact. Parts I & II. The case of elastic similarity. The general case (elastic dissimilarity), Int J Solids Struct 38:4507-4533, 2001.
-
(2001)
Int J Solids Struct
, vol.38
, pp. 4507-4533
-
-
Ciavarella, M.1
Decuzzi, P.2
-
17
-
-
47149105263
-
-
ABAQUS® Version 6.3, Theory and User's Manual, Hibbitt, Karlsson & Sorensen, Inc., Rhode Island, USA, 2002.
-
ABAQUS® Version 6.3, Theory and User's Manual, Hibbitt, Karlsson & Sorensen, Inc., Rhode Island, USA, 2002.
-
-
-
-
18
-
-
27744550236
-
-
National Radiological Protection Board, Chilton, UK
-
Shrimpton PC, Hillier MC, Lewis MA, Dunn M, Doses from computed tomography examinations in the UK - 2003 review, Document NRPB-W67, National Radiological Protection Board, Chilton, UK, 2005.
-
(2005)
Doses from computed tomography examinations in the UK - 2003 review, Document NRPB-W67
-
-
Shrimpton, P.C.1
Hillier, M.C.2
Lewis, M.A.3
Dunn, M.4
-
19
-
-
33644854428
-
Computer tomography for virtual models in dental imaging
-
Natali AN ed, Taylor & Francis, London, pp
-
Natali AN, Viola MM, Computer tomography for virtual models in dental imaging, in Natali AN (ed.), Dental Biomechanics, Taylor & Francis, London, pp. 39-51, 2003.
-
(2003)
Dental Biomechanics
, pp. 39-51
-
-
Natali, A.N.1
Viola, M.M.2
-
20
-
-
47149088666
-
-
MIMICS® Version 7.2, Materialise Inc, Leuven, Belgium, 2004
-
MIMICS® Version 7.2, Materialise Inc., Leuven, Belgium, 2004.
-
-
-
-
21
-
-
47149087555
-
-
Pro-Engineer Wildfire™, Version 2.0, Parametric Technology Corporation, Needham, USA, 2003
-
Pro-Engineer Wildfire™, Version 2.0, Parametric Technology Corporation, Needham, USA, 2003.
-
-
-
-
22
-
-
2342649962
-
An evaluation of interface contact profiles in two low contact bone plates
-
Field J, Edmonds-Wilson R, Stanley RM, An evaluation of interface contact profiles in two low contact bone plates, Injury 35 551-556, 2004.
-
(2004)
Injury
, vol.35
, pp. 551-556
-
-
Field, J.1
Edmonds-Wilson, R.2
Stanley, R.M.3
-
23
-
-
10444255467
-
Explicit finite element modelling of total knee replacement mechanics
-
Halloran J, Putrella AJ, Rullkoetter PJ, Explicit finite element modelling of total knee replacement mechanics, J Biomech 38 323-331, 2005.
-
(2005)
J Biomech
, vol.38
, pp. 323-331
-
-
Halloran, J.1
Putrella, A.J.2
Rullkoetter, P.J.3
-
24
-
-
0242494220
-
The relationship between cement fatigue and implant surface finish in proximal femoral prostheses
-
Lennon AB, McCormak BAO, Prendergast PJ, The relationship between cement fatigue and implant surface finish in proximal femoral prostheses, Med Eng Phys 25:833-841, 2003.
-
(2003)
Med Eng Phys
, vol.25
, pp. 833-841
-
-
Lennon, A.B.1
McCormak, B.A.O.2
Prendergast, P.J.3
-
25
-
-
47149087361
-
-
Torino, Italy
-
Fanfani F, Pierazzini A, Tomografia Computerizzata del Distretto Maxillofacciale, UTET Divisione Periodici Scientifici, Torino, Italy, 1996.
-
(1996)
Tomografia Computerizzata del Distretto Maxillofacciale, UTET Divisione Periodici Scientifici
-
-
Fanfani, F.1
Pierazzini, A.2
-
26
-
-
0030065290
-
The calibration of CT Hounsfield units for radiotherapy treatment planning
-
Schneider U, Pedroni E, Lomax A, The calibration of CT Hounsfield units for radiotherapy treatment planning, Phys Med Biol 41:111-124, 1996.
-
(1996)
Phys Med Biol
, vol.41
, pp. 111-124
-
-
Schneider, U.1
Pedroni, E.2
Lomax, A.3
-
27
-
-
85024597150
-
Discussion of edge-bonded dissimilar orthogonal elastic wedges under normal and shear loading
-
Dundurs J, Discussion of edge-bonded dissimilar orthogonal elastic wedges under normal and shear loading, J Appl Mech 36 650-652, 1969.
-
(1969)
J Appl Mech
, vol.36
, pp. 650-652
-
-
Dundurs, J.1
-
28
-
-
0016656215
-
Properties of elastic bodies in contact
-
de Pater AD, Kalker JJ eds, Delft University Press, Delft, The Netherlands, pp
-
Dundurs J, Properties of elastic bodies in contact, in de Pater AD, Kalker JJ (eds.), Mechanics of Contact Between Deformable Bodies, Delft University Press, Delft, The Netherlands, pp. 54-66, 1975.
-
(1975)
Mechanics of Contact Between Deformable Bodies
, pp. 54-66
-
-
Dundurs, J.1
|