메뉴 건너뛰기




Volumn , Issue , 2007, Pages

Automated meter reading systems in outage management

Author keywords

AMR; Power distribution; Power distribution control; Power system faults; SCADA systems

Indexed keywords

BOOLEAN FUNCTIONS; CONTROL SYSTEMS; DATA ACQUISITION; DATA COMMUNICATION SYSTEMS; DISTRIBUTED PARAMETER NETWORKS; DISTRIBUTION OF GOODS; ELECTRIC MEASURING INSTRUMENTS; ELECTRIC NETWORK ANALYSIS; METRIC SYSTEM; OUTAGES; POWER ELECTRONICS; SCADA SYSTEMS; TREES (MATHEMATICS); WATER METERS;

EID: 47149092454     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/CPE.2007.4296493     Document Type: Conference Paper
Times cited : (17)

References (9)
  • 1
    • 0002135675 scopus 로고    scopus 로고
    • Distribution System Technology for the 21st Century
    • May
    • K. Stahlkopf and W. Malcolm, Distribution System Technology for the 21st Century, The Electricity Journal, vol. 11, no 4, pp. 49-57, May 1998.
    • (1998) The Electricity Journal , vol.11 , Issue.4 , pp. 49-57
    • Stahlkopf, K.1    Malcolm, W.2
  • 2
    • 46249101243 scopus 로고
    • IEEE Recommended practice for monitoring electric power quality
    • IEEE Recommended practice for monitoring electric power quality, IEEE Std. 1159, 1995.
    • (1995) IEEE Std , vol.1159
  • 3
    • 0036577208 scopus 로고    scopus 로고
    • Knowledge-based system for distribution system outage locating using comprehensive information
    • May
    • Y. Liu, N. N. Schulz, Knowledge-based system for distribution system outage locating using comprehensive information, IEEE Trans. Power Systems, vol. 17, no 2, pp. 451-456, May 2002.
    • (2002) IEEE Trans. Power Systems , vol.17 , Issue.2 , pp. 451-456
    • Liu, Y.1    Schulz, N.N.2
  • 4
    • 47149102216 scopus 로고    scopus 로고
    • Outage management via powerline communication based automated meter reading systems
    • Masters Thesis dissertation, Mississippi State University, May
    • T. Venganti, "Outage management via powerline communication based automated meter reading systems", Masters Thesis dissertation, Mississippi State University, May 2004.
    • (2004)
    • Venganti, T.1
  • 5
    • 7244242326 scopus 로고    scopus 로고
    • A Solution to Remote Detection of Illegal Electricity Usage via Power Line Communications
    • October
    • I. H. Cavdar, A Solution to Remote Detection of Illegal Electricity Usage via Power Line Communications, IEEE Trans. Power Delivery, vol. 19, no. 4, pp. 1663- 1667 October 2004.
    • (2004) IEEE Trans. Power Delivery , vol.19 , Issue.4 , pp. 1663-1667
    • Cavdar, I.H.1
  • 6
    • 0035481541 scopus 로고    scopus 로고
    • Outage management through AMR systems using an intelligent data filter
    • October
    • K. Sridharan, N. N. Schulz, Outage management through AMR systems using an intelligent data filter, IEEE Trans. Power Delivery.., vol. 16, no. 4, pp. 669-675, October 2001.
    • (2001) IEEE Trans. Power Delivery , vol.16 , Issue.4 , pp. 669-675
    • Sridharan, K.1    Schulz, N.N.2
  • 8
    • 0021481517 scopus 로고
    • TWACS a new viable two-way automatic communication system for distribution networks. Part II: Inbound Communication
    • Dallas, Texas, January 29-February 3
    • S. T. Mak, TWACS a new viable two-way automatic communication system for distribution networks. Part II: Inbound Communication, Proceedings of IEEE/PES 1994 winter meeting, Dallas, Texas, January 29-February 3, 1994.
    • (1994) Proceedings of IEEE/PES 1994 winter meeting
    • Mak, S.T.1
  • 9
    • 47149096002 scopus 로고    scopus 로고
    • Radial Test Feeders, IEEE Distribution System Analysis Subcommittee, IEEE Power Engineering Society, June
    • Radial Test Feeders - IEEE Distribution System Analysis Subcommittee, IEEE Power Engineering Society, June 2004.
    • (2004)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.