-
1
-
-
47149119135
-
-
Heart Disease and Stroke Statistics, 2005 Update, Dallas, TX, American Heart Association.
-
Heart Disease and Stroke Statistics, 2005 Update, Dallas, TX, American Heart Association.
-
-
-
-
2
-
-
0028123099
-
A Comparison of Balloon-Expandable-Stent Implantation With Balloon Angioplasty in Patients With Coronary Artery Disease
-
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., Belardi, J., Sigwart, U., Colombo, A., Goy, J. J., van den Heuvel, P., Delcan, J., and Morel, M., 1994, "A Comparison of Balloon-Expandable-Stent Implantation With Balloon Angioplasty in Patients With Coronary Artery Disease," N. Engl. J. Med., 331(8), pp. 489-495.
-
(1994)
N. Engl. J. Med
, vol.331
, Issue.8
, pp. 489-495
-
-
Serruys, P.W.1
de Jaegere, P.2
Kiemeneij, F.3
Macaya, C.4
Rutsch, W.5
Heyndrickx, G.6
Emanuelsson, H.7
Marco, J.8
Legrand, V.9
Materne, P.10
Belardi, J.11
Sigwart, U.12
Colombo, A.13
Goy, J.J.14
van den Heuvel, P.15
Delcan, J.16
Morel, M.17
-
3
-
-
0027934377
-
-
Fischman, D. L., Leon, M. B., Bairn, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., Cleman, M., Heuser, R., Almond, D., Teirstein, P. S., Fish, R. D., Colombo, A., Blinker, J., Moses, J., Shaknovich, A., Hirshfeld, J., Bailey, S., Ellis, S., Rake, R., and Goldberg, S., 1994, A Randomized Comparison of Coronary-Stent Placement and Balloon Angioplasty in the Treatment of Coronary Artery Disease, N. Engl. J. Med., 331(8), pp. 496-501.
-
Fischman, D. L., Leon, M. B., Bairn, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., Cleman, M., Heuser, R., Almond, D., Teirstein, P. S., Fish, R. D., Colombo, A., Blinker, J., Moses, J., Shaknovich, A., Hirshfeld, J., Bailey, S., Ellis, S., Rake, R., and Goldberg, S., 1994, "A Randomized Comparison of Coronary-Stent Placement and Balloon Angioplasty in the Treatment of Coronary Artery Disease," N. Engl. J. Med., 331(8), pp. 496-501.
-
-
-
-
4
-
-
0033230602
-
Randomized Comparison of Coronary Stent Implantation and Balloon Angioplasty in the Treatment of De Novo Coronary Artery Lesions (START)
-
Betrui, A., Masotti, M., Serra, A., Alonso, J., Fernandez-Aviles, F., Gimeno, F., Colman, T., Zueco, J., Delcan, J. L., Garcia, E., and Calabuig, J., 1999, "Randomized Comparison of Coronary Stent Implantation and Balloon Angioplasty in the Treatment of De Novo Coronary Artery Lesions (START)," J. Am. Coll. Cardiol., 34(5), pp. 1498-1506.
-
(1999)
J. Am. Coll. Cardiol
, vol.34
, Issue.5
, pp. 1498-1506
-
-
Betrui, A.1
Masotti, M.2
Serra, A.3
Alonso, J.4
Fernandez-Aviles, F.5
Gimeno, F.6
Colman, T.7
Zueco, J.8
Delcan, J.L.9
Garcia, E.10
Calabuig, J.11
-
5
-
-
32044431845
-
Coronary-Artery Stents
-
Serruys, P. W., Kutryk, M. J. B., and Sousa, J. E., 2006, "Coronary-Artery Stents," N. Engl. J. Med., 354(5), pp. 483-495.
-
(2006)
N. Engl. J. Med
, vol.354
, Issue.5
, pp. 483-495
-
-
Serruys, P.W.1
Kutryk, M.J.B.2
Sousa, J.E.3
-
6
-
-
33745953822
-
Review of Randomized Clinical Trials of Drug-Eluting Stents for the Prevention of In-Stent Restenosis
-
Eisenberg, M. J., and Konnyu, K. J., 2006, "Review of Randomized Clinical Trials of Drug-Eluting Stents for the Prevention of In-Stent Restenosis," Am. J. Cardiol., 98(3), pp. 375-382.
-
(2006)
Am. J. Cardiol
, vol.98
, Issue.3
, pp. 375-382
-
-
Eisenberg, M.J.1
Konnyu, K.J.2
-
7
-
-
33745233024
-
Pathology of Drug-Eluting Stents in Humans: Delayed Healing and Late Thrombotic Risk
-
Joner, M., Finn, A. V., Farb, A., Mont, E. K., Kolodgie, F. D., Ladich, E., Kutys, R., Skorija, K., Gold, H. K., and Virmani, R., 2006, "Pathology of Drug-Eluting Stents in Humans: Delayed Healing and Late Thrombotic Risk," J. Am. Coll. Cardiol., 48(1), pp. 193-202.
-
(2006)
J. Am. Coll. Cardiol
, vol.48
, Issue.1
, pp. 193-202
-
-
Joner, M.1
Finn, A.V.2
Farb, A.3
Mont, E.K.4
Kolodgie, F.D.5
Ladich, E.6
Kutys, R.7
Skorija, K.8
Gold, H.K.9
Virmani, R.10
-
8
-
-
24644523719
-
Incremental Cost-Effectiveness of Drug-Eluting Stents Compared With a Third-Generation Bare-Metal Stent in a Real-World Setting: Randomised Basel Stent Kosten Effektivitäts Trial (BASKET)
-
Kaiser, C., Brunner, H. P., Bruser, P. T., Bonetti, P. O., Osswald, S., Linka, A., Bernheim, A., Zutter, A., Zellweger, M., Grize, L., and Pfisterer, M. E., 2005. "Incremental Cost-Effectiveness of Drug-Eluting Stents Compared With a Third-Generation Bare-Metal Stent in a Real-World Setting: Randomised Basel Stent Kosten Effektivitäts Trial (BASKET)," Lancet, 366(9489), pp. 921-929.
-
(2005)
Lancet
, vol.366
, Issue.9489
, pp. 921-929
-
-
Kaiser, C.1
Brunner, H.P.2
Bruser, P.T.3
Bonetti, P.O.4
Osswald, S.5
Linka, A.6
Bernheim, A.7
Zutter, A.8
Zellweger, M.9
Grize, L.10
Pfisterer, M.E.11
-
9
-
-
0033547812
-
Pathology of Acute and Chronic. Coronary Stenting in Humans
-
Farb, A., Sangiorgi, G., Carter, A. J., Walley, V. M., Edwards, W. D., Schwartz, R. S., and Virmani, R., 1999, "Pathology of Acute and Chronic. Coronary Stenting in Humans," Circulation, 99(1), pp. 44-52.
-
(1999)
Circulation
, vol.99
, Issue.1
, pp. 44-52
-
-
Farb, A.1
Sangiorgi, G.2
Carter, A.J.3
Walley, V.M.4
Edwards, W.D.5
Schwartz, R.S.6
Virmani, R.7
-
10
-
-
0033525544
-
Balloon-Artery Interactions During Stent Placement: A Finite Element Analysis Approach to Pressure, Compliance, and Stent Design as Contributors to Vascular Injury
-
Rogers, C., Tseng, D. Y., Squire, J. C., and Edelman, E. R., 1999, "Balloon-Artery Interactions During Stent Placement: A Finite Element Analysis Approach to Pressure, Compliance, and Stent Design as Contributors to Vascular Injury," Circ. Res., 84(4), pp. 378-383.
-
(1999)
Circ. Res
, vol.84
, Issue.4
, pp. 378-383
-
-
Rogers, C.1
Tseng, D.Y.2
Squire, J.C.3
Edelman, E.R.4
-
11
-
-
0029013213
-
Luminal Loss and Site of Restenosis After Palmaz-Schatz Coronary Stent Implantation
-
Ikari, Y., Kazuhiro, H., Tamura, T., Saeki, F., and Yamaguchi, T., 1995, "Luminal Loss and Site of Restenosis After Palmaz-Schatz Coronary Stent Implantation," Am. J. Cardiol., 76(3), pp. 117-120.
-
(1995)
Am. J. Cardiol
, vol.76
, Issue.3
, pp. 117-120
-
-
Ikari, Y.1
Kazuhiro, H.2
Tamura, T.3
Saeki, F.4
Yamaguchi, T.5
-
12
-
-
18344376936
-
Dynamics of Endovascular Stent Expansion,
-
Ph.D. thesis, Massachusetts Institute of Technology, Cambridge, MA
-
Squire, J. C., 2000, "Dynamics of Endovascular Stent Expansion," Ph.D. thesis, Massachusetts Institute of Technology, Cambridge, MA.
-
(2000)
-
-
Squire, J.C.1
-
13
-
-
0034333737
-
Mechanical Behaviour Modelling of Balloon-Expandable Stents
-
Dumoulin, C., and Cochelin, B., 2000, "Mechanical Behaviour Modelling of Balloon-Expandable Stents," J. Biomech., 33(11), pp. 1461-1470.
-
(2000)
J. Biomech
, vol.33
, Issue.11
, pp. 1461-1470
-
-
Dumoulin, C.1
Cochelin, B.2
-
14
-
-
0035079178
-
A Method for Investigating the Mechanical Properties of Intracoronary Stents Using Finite Element Numerical Simulation
-
Tan, L. B., Webb, D. C., Kormi, K., and Al-Hassani, S. T. S., 2001, "A Method for Investigating the Mechanical Properties of Intracoronary Stents Using Finite Element Numerical Simulation," Int. J. Cardiol., 78(1), pp. 51-67.
-
(2001)
Int. J. Cardiol
, vol.78
, Issue.1
, pp. 51-67
-
-
Tan, L.B.1
Webb, D.C.2
Kormi, K.3
Al-Hassani, S.T.S.4
-
15
-
-
20444475661
-
Cardiovascular Stent Design and Vessel Stresses: A Finite Element Analysis
-
Lally, C., Dolan, F., and Prendergast, P. J., 2005, "Cardiovascular Stent Design and Vessel Stresses: A Finite Element Analysis," J. Biomech., 38(8), pp. 1574-1581.
-
(2005)
J. Biomech
, vol.38
, Issue.8
, pp. 1574-1581
-
-
Lally, C.1
Dolan, F.2
Prendergast, P.J.3
-
16
-
-
33749260906
-
-
Springer-Verlag, Heidelberg, pp
-
Holzapfel, G. A., Stadler, M., and Gasser, T. C., 2005, Mechanics of Biological Tissue, Springer-Verlag, Heidelberg, pp. 207-220.
-
(2005)
Mechanics of Biological Tissue
, pp. 207-220
-
-
Holzapfel, G.A.1
Stadler, M.2
Gasser, T.C.3
-
17
-
-
47149105895
-
-
Auricchio, F., Di Loreto, M., and Sacco, E., 2000, Finite-Element Analysis of a Stenotic Artery Revascularization Through a Stent Insertion, Comput. Methods Biomech. Biomed. Eng., 0, pp. 1-15.
-
Auricchio, F., Di Loreto, M., and Sacco, E., 2000, "Finite-Element Analysis of a Stenotic Artery Revascularization Through a Stent Insertion," Comput. Methods Biomech. Biomed. Eng., 0, pp. 1-15.
-
-
-
-
18
-
-
10444258936
-
A Predictive Study of the Mechanical Behaviour of Coronary Stents by Computer Modeling
-
Migliavacca, F., Petrini, L., Montanari, V., Quagliana, I., Auricchio, F., and Dubini, G., 2005, "A Predictive Study of the Mechanical Behaviour of Coronary Stents by Computer Modeling," Med. Eng. Phys., 27(1), pp. 13-18.
-
(2005)
Med. Eng. Phys
, vol.27
, Issue.1
, pp. 13-18
-
-
Migliavacca, F.1
Petrini, L.2
Montanari, V.3
Quagliana, I.4
Auricchio, F.5
Dubini, G.6
-
19
-
-
33750258127
-
Finite Element Analysis and Stent Design: Reduction of Dogboning
-
De Beule, M., Van Impe, R., Verhegghe, B., Segers, P., and Verdonck, P., 2006, "Finite Element Analysis and Stent Design: Reduction of Dogboning," Technol. Health Care, 14(4), pp. 233-241.
-
(2006)
Technol. Health Care
, vol.14
, Issue.4
, pp. 233-241
-
-
De Beule, M.1
Van Impe, R.2
Verhegghe, B.3
Segers, P.4
Verdonck, P.5
-
20
-
-
27744557004
-
Analysis of the Transient Expansion Behavior and Design Optimization of Coronary Stents by Finite Element Method
-
Wang, W. Q., Liang, D. K., Yang, D. Z., and Qi, M., 2006, "Analysis of the Transient Expansion Behavior and Design Optimization of Coronary Stents by Finite Element Method," J. Biomech., 39(1), pp. 21-32.
-
(2006)
J. Biomech
, vol.39
, Issue.1
, pp. 21-32
-
-
Wang, W.Q.1
Liang, D.K.2
Yang, D.Z.3
Qi, M.4
-
21
-
-
34147182302
-
Plasticity in the Mechanical Behaviour of Cardiovascular Stents During Stent Preparation (Crimping) and Placement (Expansion)
-
De Beule, M., Mortier, P., Van Impe, R., Verhegghe, B., Segers, P., and Verdonck, P., 2007, "Plasticity in the Mechanical Behaviour of Cardiovascular Stents During Stent Preparation (Crimping) and Placement (Expansion)," Key Eng. Mater., 340-341, pp. 847-852.
-
(2007)
Key Eng. Mater
, vol.340-341
, pp. 847-852
-
-
De Beule, M.1
Mortier, P.2
Van Impe, R.3
Verhegghe, B.4
Segers, P.5
Verdonck, P.6
-
22
-
-
0038610567
-
The Stress-Strain Behavior of Coronary Stent Struts is Size Dependent
-
Murphy, B. P., Savage, P., McHugh, P. E., and Quinn, D. F., 2003, "The Stress-Strain Behavior of Coronary Stent Struts is Size Dependent," Ann. Biomed. Eng., 31(6), pp. 686-691.
-
(2003)
Ann. Biomed. Eng
, vol.31
, Issue.6
, pp. 686-691
-
-
Murphy, B.P.1
Savage, P.2
McHugh, P.E.3
Quinn, D.F.4
-
23
-
-
34147118091
-
Plasticity as a Lifesaver in the Design of Cardiovascular Stents
-
De Beule, M., Mortier, P., Belis, J., Van Impe, R., Verhegghe, B., and Verdonck, P., 2007, "Plasticity as a Lifesaver in the Design of Cardiovascular Stents," Key Eng. Mater., 340-341, pp. 841-846.
-
(2007)
Key Eng. Mater
, vol.340-341
, pp. 841-846
-
-
De Beule, M.1
Mortier, P.2
Belis, J.3
Van Impe, R.4
Verhegghe, B.5
Verdonck, P.6
-
24
-
-
47149117085
-
-
Van Nostrand Reinhold, New York, Chap. 2, Pt. I, p
-
Timoshenko, S., 1955, Strength of Materials, Van Nostrand Reinhold, New York, Chap. 2, Pt. I, p. 45.
-
(1955)
Strength of Materials
, pp. 45
-
-
Timoshenko, S.1
-
25
-
-
20844456925
-
Intravascular Ultrasonic Assessment of Stent Diameters Derived From Manufacturer's Compliance Charts
-
de Ribamar Costa, J., Mintz, G. S., Carlier, S. G., Costa, R. A., Fujii, K., Sano, K., Kimura, M., Lui, J., Weisz, G., Moussa, I., Dangas, G., Mehran, R., Lansky, A. J., Kreps, E. M., Collins, M., Stone, G. W., Moses, J. W., and Leon, M. B., 2005, "Intravascular Ultrasonic Assessment of Stent Diameters Derived From Manufacturer's Compliance Charts," Am. J. Cardiol., 96(1), pp. 74-78.
-
(2005)
Am. J. Cardiol
, vol.96
, Issue.1
, pp. 74-78
-
-
de Ribamar Costa, J.1
Mintz, G.S.2
Carlier, S.G.3
Costa, R.A.4
Fujii, K.5
Sano, K.6
Kimura, M.7
Lui, J.8
Weisz, G.9
Moussa, I.10
Dangas, G.11
Mehran, R.12
Lansky, A.J.13
Kreps, E.M.14
Collins, M.15
Stone, G.W.16
Moses, J.W.17
Leon, M.B.18
|