메뉴 건너뛰기




Volumn 86, Issue 1, 2008, Pages 289-291

Use of Transcranial Doppler Ultrasound in Endovascular Repair of a Type B Aortic Dissection

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AORTA DISSECTION; AORTOGRAPHY; ARTICLE; CAROTID ARTERY OBSTRUCTION; CASE REPORT; COMPUTER ASSISTED TOMOGRAPHY; DOPPLER FLOWMETRY; ENDOVASCULAR SURGERY; HUMAN; MALE; PRIORITY JOURNAL; ANGIOPLASTY; BLOOD VESSEL PROSTHESIS; BLOOD VESSEL TRANSPLANTATION; BRAIN ISCHEMIA; DISSECTING ANEURYSM; DOPPLER ECHOGRAPHY; ECHOGRAPHY; FOLLOW UP; METHODOLOGY; MIDDLE AGED; PATIENT MONITORING; POSTOPERATIVE COMPLICATION; RISK ASSESSMENT; SENSITIVITY AND SPECIFICITY; THORACIC AORTA ANEURYSM; TREATMENT OUTCOME;

EID: 47049109414     PISSN: 00034975     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.athoracsur.2008.01.039     Document Type: Article
Times cited : (9)

References (5)
  • 1
    • 13244258388 scopus 로고    scopus 로고
    • Endovascular treatment of thoracic aortic aneurysms: results of the phase II multicenter trial of the GORE TAG thoracic endoprosthesis
    • Makaroun M.S., Dillavou E.D., Kee S.T., et al. Endovascular treatment of thoracic aortic aneurysms: results of the phase II multicenter trial of the GORE TAG thoracic endoprosthesis. J Vasc Surg 41 (2005) 1-9
    • (2005) J Vasc Surg , vol.41 , pp. 1-9
    • Makaroun, M.S.1    Dillavou, E.D.2    Kee, S.T.3
  • 3
    • 0031688743 scopus 로고    scopus 로고
    • Influence of guidewire and catheter type on the frequency of cerebral microembolic signals during left heart catheterization
    • Braekken S.K., Endresen K., Russell D., Brucher R., and Kjekshus J. Influence of guidewire and catheter type on the frequency of cerebral microembolic signals during left heart catheterization. Am J Cardiol 82 (1998) 632-637
    • (1998) Am J Cardiol , vol.82 , pp. 632-637
    • Braekken, S.K.1    Endresen, K.2    Russell, D.3    Brucher, R.4    Kjekshus, J.5
  • 4
    • 12844250564 scopus 로고    scopus 로고
    • Cerebral monitoring with transcranial Doppler ultrasonography improves neurologic outcome during repairs of acute type A aortic dissection
    • Estrera A., Garami Z., Miller III C.C., et al. Cerebral monitoring with transcranial Doppler ultrasonography improves neurologic outcome during repairs of acute type A aortic dissection. J Thorac Cardiovasc Surg 129 (2005) 277-285
    • (2005) J Thorac Cardiovasc Surg , vol.129 , pp. 277-285
    • Estrera, A.1    Garami, Z.2    Miller III, C.C.3
  • 5
    • 0037111119 scopus 로고    scopus 로고
    • Cerebral microemboli and cognitive impairment
    • Russel D. Cerebral microemboli and cognitive impairment. J Neurol Science 203-204 (2002) 211-214
    • (2002) J Neurol Science , vol.203-204 , pp. 211-214
    • Russel, D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.