메뉴 건너뛰기




Volumn 130, Issue 1, 2008, Pages 0110011-0110015

Potential of polygeneration with solar thermal and photovoltaic systems

Author keywords

Absorption cooling; Cogeneration; Concentrators; Photovoltaics; Polygeneration

Indexed keywords

CONCENTRATION LEVELS; CONVERTERS (PAPER INDUSTRY); DIRECT USE; ENERGY LOSSES; FREE PARAMETERS; INCIDENT RADIATIONS; OPERATING TEMPERATURES; OPTICAL (PET) (OPET); OVERALL EFFICIENCY; PHOTOVOLTAIC (PV) SYSTEMS; PHOTOVOLTAIC RECEIVERS; POLY-GENERATION; RADIATION ENERGY; SOLAR THERMAL;

EID: 47049095786     PISSN: 01996231     EISSN: None     Source Type: Journal    
DOI: 10.1115/1.2804618     Document Type: Conference Paper
Times cited : (46)

References (16)
  • 3
    • 0037122462 scopus 로고    scopus 로고
    • A High-Efficiency Triple Cycle for Solar Power Generation
    • Kribus, A., 2002, "A High-Efficiency Triple Cycle for Solar Power Generation," Sol. Energy, 72, pp. 1-11.
    • (2002) Sol. Energy , vol.72 , pp. 1-11
    • Kribus, A.1
  • 4
    • 0033908438 scopus 로고    scopus 로고
    • High-Efficiency Solar Cooling
    • Gordon, J. M., and Ng, C. M., 2000, "High-Efficiency Solar Cooling," Sol. Energy, 68, pp. 23-31.
    • (2000) Sol. Energy , vol.68 , pp. 23-31
    • Gordon, J.M.1    Ng, C.M.2
  • 5
    • 0032058403 scopus 로고    scopus 로고
    • Electricity and Potable Water From a Solar Tower Power Plant
    • Rheinlander, I., and Lippke, F., 1998, "Electricity and Potable Water From a Solar Tower Power Plant," Renewable Energy, 14, pp. 23-28.
    • (1998) Renewable Energy , vol.14 , pp. 23-28
    • Rheinlander, I.1    Lippke, F.2
  • 6
    • 0033149423 scopus 로고    scopus 로고
    • Limiting Efficiency of Coupled Thermal and Photovoltaic Converters
    • Luque, A., and Martí, A., 1999, "Limiting Efficiency of Coupled Thermal and Photovoltaic Converters," Sol. Energy Mater. Sol. Cells, 58, pp. 147-165.
    • (1999) Sol. Energy Mater. Sol. Cells , vol.58 , pp. 147-165
    • Luque, A.1    Martí, A.2
  • 7
    • 33646873975 scopus 로고    scopus 로고
    • Analysis of Potential Conversion Efficiency of a Solar Hybrid System With High Temperature Stage
    • Vorobiev, Y. V., Gonzalez-Hernandez, J., and Kribus, A., 2006, "Analysis of Potential Conversion Efficiency of a Solar Hybrid System With High Temperature Stage," J. Sol. Energy Eng., 128, pp. 258-260.
    • (2006) J. Sol. Energy Eng , vol.128 , pp. 258-260
    • Vorobiev, Y.V.1    Gonzalez-Hernandez, J.2    Kribus, A.3
  • 8
    • 4444364707 scopus 로고    scopus 로고
    • PV Thermal Systems: PV Panels Supplying Renewable Electricity and Heat
    • Van Helden, W. G. J., van Zolingen, R. J. C., and Zondag, H. A., 2004, "PV Thermal Systems: PV Panels Supplying Renewable Electricity and Heat," Prog. Photovoltaics, 12, pp. 415-426.
    • (2004) Prog. Photovoltaics , vol.12 , pp. 415-426
    • Van Helden, W.G.J.1    van Zolingen, R.J.C.2    Zondag, H.A.3
  • 9
    • 12444257677 scopus 로고    scopus 로고
    • Performance of a Concentrating Photovoltaic/Thermal Solar Collector
    • Coventry, J. S., 2005, "Performance of a Concentrating Photovoltaic/Thermal Solar Collector," Sol. Energy, 78(2), pp. 211-222.
    • (2005) Sol. Energy , vol.78 , Issue.2 , pp. 211-222
    • Coventry, J.S.1
  • 10
    • 34547121464 scopus 로고    scopus 로고
    • Solar Cooling With Concentrating Photovoltaic/Thermal (CPVT) Systems
    • Mittelman, G., Kribus, A., and Dayan, A., 2007, "Solar Cooling With Concentrating Photovoltaic/Thermal (CPVT) Systems," Energy Convers. Manage., 48, 2481-2490.
    • (2007) Energy Convers. Manage , vol.48 , pp. 2481-2490
    • Mittelman, G.1    Kribus, A.2    Dayan, A.3
  • 11
    • 84870497139 scopus 로고    scopus 로고
    • Desalination With Concentrating Photovoltaic Systems
    • ISES, Orlando
    • Mittelman, G., Kribus, A., and Dayan, A., 2005, "Desalination With Concentrating Photovoltaic Systems," Solar World Congress, ISES, Orlando.
    • (2005) Solar World Congress
    • Mittelman, G.1    Kribus, A.2    Dayan, A.3
  • 12
    • 27644552271 scopus 로고    scopus 로고
    • Annual Output Estimation of Concentrator Photovoltaic Systems Using High-Efficiency InGaP/InGaAs/Ge Triple-Junction Solar Cells Based on Experimental Solar Cell's Characteristics and Field-Test Meteorological Data
    • Nishioka, K., Takamoto, T., Agui, T., Kaneiwa, M., Uraoka, Y., and Fuyuki, T., 2006, "Annual Output Estimation of Concentrator Photovoltaic Systems Using High-Efficiency InGaP/InGaAs/Ge Triple-Junction Solar Cells Based on Experimental Solar Cell's Characteristics and Field-Test Meteorological Data," Sol. Energy Mater. Sol. Cells, 90, pp. 57-67.
    • (2006) Sol. Energy Mater. Sol. Cells , vol.90 , pp. 57-67
    • Nishioka, K.1    Takamoto, T.2    Agui, T.3    Kaneiwa, M.4    Uraoka, Y.5    Fuyuki, T.6
  • 13
    • 33748317877 scopus 로고    scopus 로고
    • Super High-Efficiency Multi-Junction and Concentrator Solar Cells
    • Yamaguchi, M., Takamoto, T., and Araki, K., 2006, "Super High-Efficiency Multi-Junction and Concentrator Solar Cells," Sol. Energy Mater. Sol. Cells, 90, pp. 3068-3077.
    • (2006) Sol. Energy Mater. Sol. Cells , vol.90 , pp. 3068-3077
    • Yamaguchi, M.1    Takamoto, T.2    Araki, K.3
  • 14
    • 10044228342 scopus 로고    scopus 로고
    • Evaluation of Temperature Characteristics of High-Efficiency InGaP/InGaAs/Ge Triple-Junction Solar Cells Under Concentration
    • Nishioka, K., Takamoto, T., Agui, T., Kaneiwa, M., Uraoka, Y., and Fuyuki, T., 2005, "Evaluation of Temperature Characteristics of High-Efficiency InGaP/InGaAs/Ge Triple-Junction Solar Cells Under Concentration," Sol. Energy Mater. Sol. Cells, 85, pp. 429-436.
    • (2005) Sol. Energy Mater. Sol. Cells , vol.85 , pp. 429-436
    • Nishioka, K.1    Takamoto, T.2    Agui, T.3    Kaneiwa, M.4    Uraoka, Y.5    Fuyuki, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.