-
1
-
-
33846027100
-
How flow-injection analysis (FIA) over the past 25 years has changed our way of performing chemical analysis
-
Hansen E.H., and Miró M. How flow-injection analysis (FIA) over the past 25 years has changed our way of performing chemical analysis. Trends Anal Chem 26 (2007) 18
-
(2007)
Trends Anal Chem
, vol.26
, pp. 18
-
-
Hansen, E.H.1
Miró, M.2
-
2
-
-
0038784768
-
Solid phase extraction of trace elements
-
Camel V. Solid phase extraction of trace elements. Spectrochim Acta Part B 58 (2003) 1177
-
(2003)
Spectrochim Acta Part B
, vol.58
, pp. 1177
-
-
Camel, V.1
-
3
-
-
12844288140
-
Knotted reactors and their role in flow-injection on-line preconcentration systems coupled to atomic spectrometry-based detectors
-
Cerutti S., Martinez L.D., and Wuilloud R.G. Knotted reactors and their role in flow-injection on-line preconcentration systems coupled to atomic spectrometry-based detectors. App Spectrosc Rev 40 (2005) 71
-
(2005)
App Spectrosc Rev
, vol.40
, pp. 71
-
-
Cerutti, S.1
Martinez, L.D.2
Wuilloud, R.G.3
-
4
-
-
0034869038
-
Flame atomic absorption spectrometry with flow-injection on-line adsorption preconcentration using a knotted reactor for cadmium determination in aqueous samples
-
Garrido L., Soto R.M., Carlosena A., Lopez-Mahia P., Munategui S., and Prada D. Flame atomic absorption spectrometry with flow-injection on-line adsorption preconcentration using a knotted reactor for cadmium determination in aqueous samples. Anal Lett 34 (2001) 1763
-
(2001)
Anal Lett
, vol.34
, pp. 1763
-
-
Garrido, L.1
Soto, R.M.2
Carlosena, A.3
Lopez-Mahia, P.4
Munategui, S.5
Prada, D.6
-
5
-
-
0038291604
-
Selective measurement of ultratrace methylmercury in fish by flow injection on-line microcolumn displacement sorption preconcentration and separation coupled with electrothermal atomic absorption spectrometry
-
Yan X.P., Li Y., and Jiang Y. Selective measurement of ultratrace methylmercury in fish by flow injection on-line microcolumn displacement sorption preconcentration and separation coupled with electrothermal atomic absorption spectrometry. Anal Chem 75 (2003) 2251
-
(2003)
Anal Chem
, vol.75
, pp. 2251
-
-
Yan, X.P.1
Li, Y.2
Jiang, Y.3
-
6
-
-
0038036850
-
A comparison of enrichment factor of knotted and serpentine reactors using flow injection sorption and preconcentration for the off-line determination of some trace elements by inductively coupled plasma mass spectrometry
-
Liawruangrath S., Som-aum W., and Thowshend A. A comparison of enrichment factor of knotted and serpentine reactors using flow injection sorption and preconcentration for the off-line determination of some trace elements by inductively coupled plasma mass spectrometry. Talanta 58 (2002) 1177
-
(2002)
Talanta
, vol.58
, pp. 1177
-
-
Liawruangrath, S.1
Som-aum, W.2
Thowshend, A.3
-
7
-
-
22544464136
-
Flow on-line sorption preconcentration in a knotted reactor coupled with electrothermal atomic absorption spectrometry for selective As(III) determination in sea-water samples
-
Herbello-Hermelo P., Barciela-Alonso M.C., Bermejo-Barrera A., and Bermejo-Barrera P. Flow on-line sorption preconcentration in a knotted reactor coupled with electrothermal atomic absorption spectrometry for selective As(III) determination in sea-water samples. J Anal Atom Spectrom 20 (2005) 662
-
(2005)
J Anal Atom Spectrom
, vol.20
, pp. 662
-
-
Herbello-Hermelo, P.1
Barciela-Alonso, M.C.2
Bermejo-Barrera, A.3
Bermejo-Barrera, P.4
-
8
-
-
33746210088
-
Evaluation of polychlorotrifluoroethylene as sorbent material for on-line solid phase extraction systems: determination of copper and lead by flame atomic absorption spectrometry in water samples
-
Anthemidis A.N., and Ioannou K.I.G. Evaluation of polychlorotrifluoroethylene as sorbent material for on-line solid phase extraction systems: determination of copper and lead by flame atomic absorption spectrometry in water samples. Anal Chim Acta 575 (2006) 126
-
(2006)
Anal Chim Acta
, vol.575
, pp. 126
-
-
Anthemidis, A.N.1
Ioannou, K.I.G.2
-
9
-
-
11144317434
-
Styrene-divinyl benzene copolymers: synthesis, characterization and their role in inorganic trace analysis
-
Rao P.T., Praveen R.S., and Daniel S. Styrene-divinyl benzene copolymers: synthesis, characterization and their role in inorganic trace analysis. Crit Rev Anal Chem 34 (2004) 177
-
(2004)
Crit Rev Anal Chem
, vol.34
, pp. 177
-
-
Rao, P.T.1
Praveen, R.S.2
Daniel, S.3
-
10
-
-
0141792814
-
Pyrrole-based conductive polymer as the solid-phase extraction medium for the preconcentration of environmental pollutants in water samples followed by gas chromatography with flame ionization and mass spectrometry detection
-
Bagheri H., and Mohammadi A. Pyrrole-based conductive polymer as the solid-phase extraction medium for the preconcentration of environmental pollutants in water samples followed by gas chromatography with flame ionization and mass spectrometry detection. J Chromatogr A 1015 (2003) 23
-
(2003)
J Chromatogr A
, vol.1015
, pp. 23
-
-
Bagheri, H.1
Mohammadi, A.2
-
11
-
-
15444368114
-
In situ deposition of poly(1,8-diaminonapthalene): from thin films to nanometer-sized structures
-
Tagowska M., Pałys B., Mazur M., Skompska M., and Jackowska K. In situ deposition of poly(1,8-diaminonapthalene): from thin films to nanometer-sized structures. Electrochim Acta 50 (2005) 2263
-
(2005)
Electrochim Acta
, vol.50
, pp. 2263
-
-
Tagowska, M.1
Pałys, B.2
Mazur, M.3
Skompska, M.4
Jackowska, K.5
-
12
-
-
35349025926
-
Conducting polymers for corrosion protection: what makes the difference between failure and success?
-
Rohwerder M., and Michalik A. Conducting polymers for corrosion protection: what makes the difference between failure and success?. Electrochim Acta 53 (2007) 1300
-
(2007)
Electrochim Acta
, vol.53
, pp. 1300
-
-
Rohwerder, M.1
Michalik, A.2
-
13
-
-
34347235836
-
Ion-selective electrodes with three-dimensionally ordered macroporous carbon as the solid contact
-
Lai C.Z., Fierke M.A., Stein A., and Buhlmann P. Ion-selective electrodes with three-dimensionally ordered macroporous carbon as the solid contact. Anal Chem 79 (2007) 4621
-
(2007)
Anal Chem
, vol.79
, pp. 4621
-
-
Lai, C.Z.1
Fierke, M.A.2
Stein, A.3
Buhlmann, P.4
-
14
-
-
33744816769
-
Rapid and effective adsorption of lead ions on fine poly(phenylenediamine) microparticles
-
Huang M.R., Peng Q.Y., and Li X.G. Rapid and effective adsorption of lead ions on fine poly(phenylenediamine) microparticles. Chem Eur J 12 (2006) 4341
-
(2006)
Chem Eur J
, vol.12
, pp. 4341
-
-
Huang, M.R.1
Peng, Q.Y.2
Li, X.G.3
-
15
-
-
0037254964
-
Removal of toxic chromate ions by the film of poly(1,8-diaminonapthalene)
-
Nasalska A., and Skompska M. Removal of toxic chromate ions by the film of poly(1,8-diaminonapthalene). J Appl Electrochem 33 (2003) 113
-
(2003)
J Appl Electrochem
, vol.33
, pp. 113
-
-
Nasalska, A.1
Skompska, M.2
-
16
-
-
0031199154
-
Sensitivity of poly 1,8-diaminonapthalene to heavy metal ions - electrochemical and vibrational spectra studies
-
Pałys B., Skompska M., and Jackowska K. Sensitivity of poly 1,8-diaminonapthalene to heavy metal ions - electrochemical and vibrational spectra studies. J Electroanal Chem 433 (1997) 41
-
(1997)
J Electroanal Chem
, vol.433
, pp. 41
-
-
Pałys, B.1
Skompska, M.2
Jackowska, K.3
-
17
-
-
4544365367
-
Facile synthesis of poly(1,8-diaminonapthalene) microparticles with a very high silver-ion adsorbability by a chemical oxidative polymerization
-
Li X.G., Huang M.R., and Li S.X. Facile synthesis of poly(1,8-diaminonapthalene) microparticles with a very high silver-ion adsorbability by a chemical oxidative polymerization. Acta Mater 52 (2004) 5363
-
(2004)
Acta Mater
, vol.52
, pp. 5363
-
-
Li, X.G.1
Huang, M.R.2
Li, S.X.3
-
18
-
-
27744445277
-
Facile synthesis and highly reactive silver ion adsorption of novel microparticles of sulfodiphenylamine and diaminonapthhalene copolymers
-
Li X.G., Liu R., and Huang M.R. Facile synthesis and highly reactive silver ion adsorption of novel microparticles of sulfodiphenylamine and diaminonapthhalene copolymers. Chem Mater 17 (2005) 5411
-
(2005)
Chem Mater
, vol.17
, pp. 5411
-
-
Li, X.G.1
Liu, R.2
Huang, M.R.3
-
19
-
-
34447253528
-
Efficient multicyclic sorption and desorption of lead ions on facilely prepared poly(m-phenylenediamine) particles with extremely strong chemoresistance
-
Huang M.R., Lu H.J., and Li X.G. Efficient multicyclic sorption and desorption of lead ions on facilely prepared poly(m-phenylenediamine) particles with extremely strong chemoresistance. J. Colloid Interface Sci 313 (2007) 72
-
(2007)
J. Colloid Interface Sci
, vol.313
, pp. 72
-
-
Huang, M.R.1
Lu, H.J.2
Li, X.G.3
-
20
-
-
34047245065
-
Multielement determination of trace metals in seawater by ICP-MS with aid of down-sized chelating resin-packed minicolumn for preconcentration
-
Rahmi D., Zhu Y., Fuimori E., Umemura T., and Haraguchi H. Multielement determination of trace metals in seawater by ICP-MS with aid of down-sized chelating resin-packed minicolumn for preconcentration. Talanta 72 (2007) 601
-
(2007)
Talanta
, vol.72
, pp. 601
-
-
Rahmi, D.1
Zhu, Y.2
Fuimori, E.3
Umemura, T.4
Haraguchi, H.5
-
21
-
-
33846553114
-
Solid phase extractive preconcentration of trace metals using p-tert-butylcalix[4]arene-1,2-crown-4-anchored chloromethylated polymeric resin beads
-
Seyhan S., Çolak M., and Demirel N. Solid phase extractive preconcentration of trace metals using p-tert-butylcalix[4]arene-1,2-crown-4-anchored chloromethylated polymeric resin beads. Anal Chim Acta 584 (2007) 462
-
(2007)
Anal Chim Acta
, vol.584
, pp. 462
-
-
Seyhan, S.1
Çolak, M.2
Demirel, N.3
-
22
-
-
33846185526
-
Flame atomic absorption spectrometry determination of trace amounts of copper after separation and preconcentration onto TDMBAC-treated analcime pyrocatechol-immobilized
-
Afzali D., Mostafavi A., Taher M.A., and Moradian A. Flame atomic absorption spectrometry determination of trace amounts of copper after separation and preconcentration onto TDMBAC-treated analcime pyrocatechol-immobilized. Talanta 71 (2007) 971
-
(2007)
Talanta
, vol.71
, pp. 971
-
-
Afzali, D.1
Mostafavi, A.2
Taher, M.A.3
Moradian, A.4
-
23
-
-
33846335463
-
Solid phase selective separation and preconcentration of Cu(II) by Cu(II)-imprinted polymethacrylic microbeads
-
Dakova I., Karadjova L., Ivanov L., Georgieva V., Evtimova B., and Georgiev G. Solid phase selective separation and preconcentration of Cu(II) by Cu(II)-imprinted polymethacrylic microbeads. Anal Chim Acta 584 (2007) 196
-
(2007)
Anal Chim Acta
, vol.584
, pp. 196
-
-
Dakova, I.1
Karadjova, L.2
Ivanov, L.3
Georgieva, V.4
Evtimova, B.5
Georgiev, G.6
-
24
-
-
0033165949
-
Pseudo-second order model for sorption processes
-
Ho Y.S., and McKay G. Pseudo-second order model for sorption processes. Process Biochem 34 (1999) 451
-
(1999)
Process Biochem
, vol.34
, pp. 451
-
-
Ho, Y.S.1
McKay, G.2
-
25
-
-
0141760573
-
Kinetic study of metal sorption on a resin modified with terakis(carboxyphenyl)porphyrin
-
Pyrzynska K., and Kilian K. Kinetic study of metal sorption on a resin modified with terakis(carboxyphenyl)porphyrin. Microchim Acta 142 (2002) 67
-
(2002)
Microchim Acta
, vol.142
, pp. 67
-
-
Pyrzynska, K.1
Kilian, K.2
-
26
-
-
0036284828
-
Inductively coupled plasma mass spectrometry for trace analysis using flow injection on-line preconcentration and time-of-flight mass analyser
-
Benkhedda K., Infante H.G., and Adams F.C. Inductively coupled plasma mass spectrometry for trace analysis using flow injection on-line preconcentration and time-of-flight mass analyser. Trends Anal Chem 21 (2002) 332
-
(2002)
Trends Anal Chem
, vol.21
, pp. 332
-
-
Benkhedda, K.1
Infante, H.G.2
Adams, F.C.3
-
27
-
-
0034777793
-
Flow injection on-line preconcentration and separation coupled with atomic (mass) spectrometry for trace element (speciation) analysis based on sorption of organo-metallic complexes in a knotted reactor
-
Yan X.P., and Jiang Y. Flow injection on-line preconcentration and separation coupled with atomic (mass) spectrometry for trace element (speciation) analysis based on sorption of organo-metallic complexes in a knotted reactor. Trends Anal Chem 20 (2001) 552
-
(2001)
Trends Anal Chem
, vol.20
, pp. 552
-
-
Yan, X.P.1
Jiang, Y.2
-
28
-
-
0030706161
-
Trace enrichment and atomic absorption spectrometric determination of lead, copper, cadmium and nickel in drinking water samples, by use of an activated carbon column
-
Soylak M., Narin I., and Dogan M. Trace enrichment and atomic absorption spectrometric determination of lead, copper, cadmium and nickel in drinking water samples, by use of an activated carbon column. Anal Lett 30 (1997) 2801
-
(1997)
Anal Lett
, vol.30
, pp. 2801
-
-
Soylak, M.1
Narin, I.2
Dogan, M.3
-
29
-
-
0031813626
-
Determination of trace amounts of copper in high-purity aluminium samples after preconcentration on an activated carbon column
-
Soylak M. Determination of trace amounts of copper in high-purity aluminium samples after preconcentration on an activated carbon column. Fresenius Environ Bull 7 (1998) 383
-
(1998)
Fresenius Environ Bull
, vol.7
, pp. 383
-
-
Soylak, M.1
|