메뉴 건너뛰기




Volumn 2, Issue , 2006, Pages 690-694

Analysis of air gap flux to detect induction motor faults

Author keywords

AC motor failure; Automatic diagnosis; Fault detection

Indexed keywords

AC MOTORS; ELECTRIC CURRENTS; ELECTRIC DRIVES; ELECTRIC FAULT LOCATION; GALLIUM ALLOYS; MONITORING; MOTORS; SAFETY ENGINEERING; STATORS; TEMPERATURE CONTROL; WINDING;

EID: 46849113868     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/UPEC.2006.367567     Document Type: Conference Paper
Times cited : (13)

References (9)
  • 1
    • 46849085121 scopus 로고    scopus 로고
    • Fallas más comunes en los motores de inducción de empresas del sector industrial del Edo. Carabobo
    • Enero
    • Eva Mohagas y Maria Mago, "Fallas más comunes en los motores de inducción de empresas del sector industrial del Edo. Carabobo" ,Trabajo de Ascenso, Universidad de Carabobo, Barbula, Venezuela, Enero 2004.
    • (2004) Trabajo de Ascenso, Universidad de Carabobo, Barbula, Venezuela
    • Mohagas, E.1    Mago, M.2
  • 2
    • 0033309003 scopus 로고    scopus 로고
    • Condition monitoring and fault diagnosis of electrical machine - a review
    • 99, 1, Phoenix, AZ, Oct
    • S. Nandi y H. A. Toliyat, "Condition monitoring and fault diagnosis of electrical machine - a review" en Proc. IEEE_JAS Annual Meeting Conference'99, vol. 1, Phoenix, AZ, Oct. 1999, pp. 197-204.
    • (1999) en Proc. IEEE_JAS Annual Meeting Conference , pp. 197-204
    • Nandi, S.1    Toliyat, H.A.2
  • 3
    • 0029404270 scopus 로고    scopus 로고
    • R. Schoen, T. Habetler, F. Kamran, y R Bartheld, Motor bearing damage detection using stator current monitoring, IEEE Trans Ind. Applicat., 31, no, 6, pp. 1274-1279, Nov./Di, 1995.
    • R. Schoen, T. Habetler, F. Kamran, y R Bartheld, "Motor bearing damage detection using stator current monitoring", IEEE Trans Ind. Applicat., vol.31, no, 6, pp. 1274-1279, Nov./Di, 1995.
  • 4
    • 0038042290 scopus 로고    scopus 로고
    • GAT stator current processing- based technique to use for induction motor rotor faults diagnosis?
    • June
    • M. E. H. Benbouzid y G. B. Kliman, GAT stator current processing- based technique to use for induction motor rotor faults diagnosis?, IEEE Trans. Energy Conversion, vol. 18, no. 2, pp. 238-244, June 2003.
    • (2003) IEEE Trans. Energy Conversion , vol.18 , Issue.2 , pp. 238-244
    • Benbouzid, M.E.H.1    Kliman, G.B.2
  • 6
    • 46849101422 scopus 로고    scopus 로고
    • Voitto Kokko, Condition monitoring of Squirrel-Cage Motors by Axial Magnetic Flux measurements, Department of Electrical Engineering, Optoelectronics and Measurement Techniques Laboratory, University of Oulu, P.O. Box 4500, FIN-90014 University of Oulu, Finland.
    • Voitto Kokko, "Condition monitoring of Squirrel-Cage Motors by Axial Magnetic Flux measurements", Department of Electrical Engineering, Optoelectronics and Measurement Techniques Laboratory, University of Oulu, P.O. Box 4500, FIN-90014 University of Oulu, Finland.
  • 7
    • 0026692578 scopus 로고
    • Detection of Broken Bars in the Cage Rotor on an Induction Machine
    • January/February
    • N. M. Elkasabgy, A. R. Eastbam and G. E. Dawsan, "Detection of Broken Bars in the Cage Rotor on an Induction Machine", IEEE Tans. On Industry Applications, vol. 28, No. 1, January/February 1992.
    • (1992) IEEE Tans. On Industry Applications , vol.28 , Issue.1
    • Elkasabgy, N.M.1    Eastbam, A.R.2    Dawsan, G.E.3
  • 9
    • 0022576973 scopus 로고    scopus 로고
    • J. Penman, M.N. Dey, A. J. Tait and W. E. Bryan, Condition monitoring of electrical drives, IEE Proc, 133, pt. B, No. 3, May 1986, pp. 142-148.
    • J. Penman, M.N. Dey, A. J. Tait and W. E. Bryan, " Condition monitoring of electrical drives", IEE Proc, vol. 133, pt. B, No. 3, May 1986, pp. 142-148.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.