Volumn 54, Issue 3-4, 2008, Pages 89-94

Caffeine monitoring in infants: Comparison of automated (VITROS® 5, 1 FS) chemistry system versus HPLC analysis

Author keywords

1 FS Chemistry system and HPLC; Caffeine; Comparison between VITROS 5; MicroTip Technology

Indexed keywords

CAFFEINE;

EID: 46849109493     PISSN: 14336510     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (1)

References (10)
  • 1
    • 0035156640 scopus 로고    scopus 로고
    • Caffeine citrate. A review of its use in apnoea of prematurity
    • Comer AM, Perry CM, Figgitt DP.. Caffeine citrate. A review of its use in apnoea of prematurity. Pediatric Drugs 2001;3:61-79
    • (2001) Pediatric Drugs , vol.3 , pp. 61-79
    • Comer, A.M.1    Perry, C.M.2    Figgitt, D.P.3
  • 2
    • 0016715437 scopus 로고
    • Caffeine therapy in neonates. Prevention of apnea and bradycardia in low birth weight infants
    • Shannon DC, Gotay F, Stein IM, Rogers MC, Todres ID, Moylan FMB. Caffeine therapy in neonates. Prevention of apnea and bradycardia in low birth weight infants. Pediatrics 1975; 55: 589-594.
    • (1975) Pediatrics , vol.55 , pp. 589-594
    • Shannon, D.C.1    Gotay, F.2    Stein, I.M.3    Rogers, M.C.4    Todres, I.D.5    Moylan, F.M.B.6
  • 3
    • 0019869243 scopus 로고
    • Pharmacologic considerations in the therapy of neonatal apnea
    • Aranda JV, Grondin D, Sasyniuk BI. Pharmacologic considerations in the therapy of neonatal apnea. Pediatr Clin N Am 1981; 28: 113-133.
    • (1981) Pediatr Clin N Am , vol.28 , pp. 113-133
    • Aranda, J.V.1    Grondin, D.2    Sasyniuk, B.I.3
  • 5
    • 46849102601 scopus 로고    scopus 로고
    • Vitros Chemistry Products Instructions for Use: Caffn Pub. No. J21161_EN
    • Vitros Chemistry Products Instructions for Use: Caffn Pub. No. J21161_EN)
  • 6
    • 46849086781 scopus 로고    scopus 로고
    • Evaluation of Precision Performance of Clinical Chemistry Devices; Approved Guideline
    • NCCLS, NCCLS, 940 West Valley Road, Suite 1400, Wayne, PA, USA
    • NCCLS. Evaluation of Precision Performance of Clinical Chemistry Devices; Approved Guideline. NCCLS document EP5-A [ISBN 1-56238-368-X]. NCCLS, 940 West Valley Road, Suite 1400, Wayne, PA 19087-1898 USA, 1999)
    • (1999) NCCLS document EP5-A [ISBN 1-56238-368-X] , pp. 19087-21898
  • 7
    • 0029967435 scopus 로고    scopus 로고
    • Quantitative structure-retention relationships of xanthines in RP HPLC systems with the new Chromolith RP-18e stationary phases
    • Schreiber-Deturmeny E. Bruguerolle B J. Quantitative structure-retention relationships of xanthines in RP HPLC systems with the new Chromolith RP-18e stationary phases Chromatogr. 1996, 677: 305-312
    • (1996) Chromatogr , vol.677 , pp. 305-312
    • Schreiber-Deturmeny, E.1    Bruguerolle, B.J.2
  • 8
    • 46849122911 scopus 로고    scopus 로고
    • Arbeitsanleitung für die Bestimmung von Theophyllin, Theobromin und Coffein mittels HPLC RECIPE Chemicals + Instruments GmbH & Co KG Labotechnik Version 3,3/97
    • Arbeitsanleitung für die Bestimmung von Theophyllin, Theobromin und Coffein mittels HPLC RECIPE Chemicals + Instruments GmbH & Co KG Labotechnik Version 3,3/97
  • 9
    • 46849107349 scopus 로고    scopus 로고
    • Caffeine Monitoring at Neonates and Premature Infants
    • poster presented at, Vienna, 22-23 June
    • Reiter-Reisacher R.B.K., Cardona F, and Herkner K.R. Caffeine Monitoring at Neonates and Premature Infants, poster presented at 2.PhD-Symposium 2006, Vienna, 22-23 June 2006
    • (2006) 2.PhD-Symposium
    • Reiter-Reisacher, R.B.K.1    Cardona, F.2    Herkner, K.R.3
  • 10
    • 0021045350 scopus 로고
    • A new biometrical procedure for testing the equality of measurements from two different analytical methods
    • Passing, H., Bablok, W. A new biometrical procedure for testing the equality of measurements from two different analytical methods, J. Clin. Chem. Clin. Biochem. 1983, 21, 709-720.
    • (1983) J. Clin. Chem. Clin. Biochem , vol.21 , pp. 709-720
    • Passing, H.1    Bablok, W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.