메뉴 건너뛰기




Volumn 23, Issue 7, 2008, Pages 2427-2428

Do we need another equation to estimate GFR from serum creatinine in renal allograft recipients?

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; CALCULATION; CALIBRATION; CORRELATION ANALYSIS; CREATININE BLOOD LEVEL; DISEASE COURSE; EVALUATION; GLOMERULUS FILTRATION RATE; HUMAN; KIDNEY ALLOGRAFT; KIDNEY TUBULE EXCRETION; LETTER; MATHEMATICAL MODEL; MUSCLE MASS; PATIENT MONITORING; PRIORITY JOURNAL; PROTEIN INTAKE; QUANTITATIVE ASSAY; RECIPIENT; STANDARDIZATION; TECHNIQUE;

EID: 46849099173     PISSN: 09310509     EISSN: 14602385     Source Type: Journal    
DOI: 10.1093/ndt/gfn119     Document Type: Letter
Times cited : (11)

References (8)
  • 1
    • 36749004434 scopus 로고    scopus 로고
    • Can modifications of the MDRD formula improve the estimation of glomerular filtration rate in renal allograft recipients?
    • Poge U, Gerhardt T, Stoffel-Wagner B et al. Can modifications of the MDRD formula improve the estimation of glomerular filtration rate in renal allograft recipients? Nephrol Dial Transplant 2007; 22: 3610-3615
    • (2007) Nephrol Dial Transplant , vol.22 , pp. 3610-3615
    • Poge, U.1    Gerhardt, T.2    Stoffel-Wagner, B.3
  • 2
    • 19944368397 scopus 로고    scopus 로고
    • Using serum creatinine to estimate glomerular filtration rate: Accuracy in good health and in chronic kidney disease
    • Rule AD, Larson TS, Bergstralh EJ et al. Using serum creatinine to estimate glomerular filtration rate: accuracy in good health and in chronic kidney disease. Ann Intern Med 2004; 141: 929-937
    • (2004) Ann Intern Med , vol.141 , pp. 929-937
    • Rule, A.D.1    Larson, T.S.2    Bergstralh, E.J.3
  • 3
    • 0036234755 scopus 로고    scopus 로고
    • Calibration and random variation of the serumcreatinine assay as critical elements of using equations to estimate glomerular filtration rate
    • Coresh J, Astor BC, McQuillan G et al. Calibration and random variation of the serumcreatinine assay as critical elements of using equations to estimate glomerular filtration rate. Am J Kidney Dis 2002; 39: 920-929
    • (2002) Am J Kidney Dis , vol.39 , pp. 920-929
    • Coresh, J.1    Astor, B.C.2    McQuillan, G.3
  • 4
    • 34250783071 scopus 로고    scopus 로고
    • Impact of creatinine calibration on performance of GFR estimating equations in a pooled individual patient database
    • Stevens LA, Manzi J, Levey AS et al. Impact of creatinine calibration on performance of GFR estimating equations in a pooled individual patient database. Am J Kidney Dis 2007; 50: 21-35
    • (2007) Am J Kidney Dis , vol.50 , pp. 21-35
    • Stevens, L.A.1    Manzi, J.2    Levey, A.S.3
  • 5
    • 33750583528 scopus 로고    scopus 로고
    • Limitations of estimating glomerular filtration rate from serum creatinine in the general population [see comment]
    • Rule AD, Rodeheffer RJ, Larson TS et al. Limitations of estimating glomerular filtration rate from serum creatinine in the general population [see comment]. Mayo Clin Proc 2006; 81: 1427-1434
    • (2006) Mayo Clin Proc , vol.81 , pp. 1427-1434
    • Rule, A.D.1    Rodeheffer, R.J.2    Larson, T.S.3
  • 6
    • 35848968871 scopus 로고    scopus 로고
    • Prevalence of chronic kidney disease in the United States
    • Coresh J, Selvin E, Stevens LA et al. Prevalence of chronic kidney disease in the United States. Jama 2007; 298: 2038-2047
    • (2007) Jama , vol.298 , pp. 2038-2047
    • Coresh, J.1    Selvin, E.2    Stevens, L.A.3
  • 7
    • 33644642582 scopus 로고    scopus 로고
    • Glomerular filtration rate estimated by cystatin C among different clinical presentations
    • Rule AD, Bergstralh EJ, Slezak JM et al. Glomerular filtration rate estimated by cystatin C among different clinical presentations. Kidney Int 2006; 69: 399-405
    • (2006) Kidney Int , vol.69 , pp. 399-405
    • Rule, A.D.1    Bergstralh, E.J.2    Slezak, J.M.3
  • 8
    • 33947591944 scopus 로고    scopus 로고
    • Assessment of changes in kidney allograft function using creatinine-based estimates of glomerular filtration rate
    • Gera M, Slezak JM, Rule AD et al. Assessment of changes in kidney allograft function using creatinine-based estimates of glomerular filtration rate. Am J Transplant 2007; 7: 880-887
    • (2007) Am J Transplant , vol.7 , pp. 880-887
    • Gera, M.1    Slezak, J.M.2    Rule, A.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.