메뉴 건너뛰기




Volumn 18, Issue 7, 2008, Pages 494-496

A 5 GHz double-sideband radar sensor chip in 0.18 μm CMOS for non-contact vital sign detection

Author keywords

Cardiopulmonary; CMOS; Double sideband; Heartbeat; Low power; Microwave; Non contact; Radar; Respiration; Sensor; Vital sign

Indexed keywords

DETECTORS; OPTICAL DESIGN; RADAR; SENSORS; TRACKING RADAR; TUNING;

EID: 46749119883     PISSN: 15311309     EISSN: None     Source Type: Journal    
DOI: 10.1109/LMWC.2008.925112     Document Type: Article
Times cited : (52)

References (5)
  • 1
    • 33646739294 scopus 로고    scopus 로고
    • Frequency tuning technique for remote detection of heartbeat and respiration using low-power double-sideband transmission in Ka-band
    • May
    • Y. Xiao, J. Lin, Boric-Lubecke, and V.M. Lubecke, "Frequency tuning technique for remote detection of heartbeat and respiration using low-power double-sideband transmission in Ka-band," IEEE Trans. Microw. Theory Tech., vol. 54, no. 5, pp. 2023-2032, May 2006.
    • (2006) IEEE Trans. Microw. Theory Tech , vol.54 , Issue.5 , pp. 2023-2032
    • Xiao, Y.1    Lin, J.2    Lubecke, B.3    Lubecke, V.M.4
  • 2
    • 33847755555 scopus 로고    scopus 로고
    • Experiment and spectral analysis of a low-power Ka-band heartbeat detector measuring from four sides of a human body
    • Dec
    • C. Li, Y. Xiao, and J. Lin, "Experiment and spectral analysis of a low-power Ka-band heartbeat detector measuring from four sides of a human body," IEEE Tram: Microw. Theory Tech., vol. 54, no. 12, pp. 4464-1471, Dec. 2006.
    • (2006) IEEE Tram: Microw. Theory Tech , vol.54 , Issue.12 , pp. 4464-1471
    • Li, C.1    Xiao, Y.2    Lin, J.3
  • 3
    • 1842527440 scopus 로고    scopus 로고
    • Range correlation and I/Q performance benefits in single-chip silicon Doppler radars for noncontact cardiopulmonary monitoring
    • Mar
    • A. D. Droitcour, O. Boric-Lubecke, V. M. Lubecke, J. Lin, and G. T. A. Kovac, "Range correlation and I/Q performance benefits in single-chip silicon Doppler radars for noncontact cardiopulmonary monitoring," IEEE Trans. Microw. Theory Tech., vol. 52, no. 3, pp. 838-848, Mar. 2004.
    • (2004) IEEE Trans. Microw. Theory Tech , vol.52 , Issue.3 , pp. 838-848
    • Droitcour, A.D.1    Boric-Lubecke, O.2    Lubecke, V.M.3    Lin, J.4    Kovac, G.T.A.5
  • 4
    • 57649217309 scopus 로고    scopus 로고
    • Design guidelines for radio frequency non-contact vital sign detection
    • Lyon, France, Aug. 23-26
    • C. Li, Y. Xiao, and J. Lin, "Design guidelines for radio frequency non-contact vital sign detection," in Proc. 29th Annu. Int. Conf. IEEE EMBS, Lyon, France, Aug. 23-26. 2007, pp. 1651-1654.
    • (2007) Proc. 29th Annu. Int. Conf. IEEE EMBS , pp. 1651-1654
    • Li, C.1    Xiao, Y.2    Lin, J.3
  • 5
    • 34548132476 scopus 로고    scopus 로고
    • Optimal carrier frequency of non-contact vital sign detectors
    • Long Beach, Jan. 9-11
    • C. Li and J. Lin, "Optimal carrier frequency of non-contact vital sign detectors," in Proc. IEEE Radio Wireless Symp., Long Beach, Jan. 9-11, 2007, pp. 281-284.
    • (2007) Proc. IEEE Radio Wireless Symp , pp. 281-284
    • Li, C.1    Lin, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.